FREQUENTLY ASKED 
QUESTIONS (FAQS)

1.  What does the Broan Automatic Make-Up Air  

Damper do?

5IF #SPBO "VUPNBUJD .BLF6Q "JS %BNQFS  UIF i%BNQFSu QSPWJEFT B

pathway for fresh air to enter a home from outdoors when a compatible 
exhaust device is operating.  The Damper opens when a compatible BEST, 
Broan Elite or Broan range hood is operating, thereby creating a known, 
controlled point for fresh air to enter the home while air is being exhausted 
from the building by the range hood.  
By operating in this manner, the Damper provides two key benefits for the 
home:

r *UGBDJMJUBUFTBJSFYDIBOHFCFUXFFOJOEPPSTBOEPVUEPPSTCZIFMQJOHUP

allow fresh air into the home to replace air which is exhausted out of 
the home.  

r #ZBMMPXJOHGSFTIBJSJOUPUIFCVJMEJOHXIFOBDPNQBUJCMFFYIBVTUEFWJDF

is on, the Damper helps to avoid negative pressure conditions within 
the home which may interfere with the proper operation of combustion 
equipment within the home.

0WFSBMM UIF %BNQFS MFUT ZPVS #&45 #SPBO &MJUF PS #SPBO FYIBVTU

devices do their job more effectively and without interfering with the proper 
operation of other home systems.

2.  Does the “Damper” provide combustion air for combustion 

appliances like a water heater or  
a furnace?

No. The Damper helps to replace air which is exhausted by a compatible 

SBOHFIPPE#VUJUEPFT/05IFMQUPSFQMBDFBJSXIJDIJTESBXOGSPNUIF

indoors by a combustion appliance like a natural gas water heater, and it 

TIPVMEOPUCFSFMJFEVQPOUPQFSGPSNUIJTGVODUJPO0OFNBJOSFBTPOGPS

this restriction is that the Damper is only open when the range hood that 
it’s connected to is operating.  So there is no assurance that the Damper 
would be open when other appliances, like a water heater, are operating.  

0UIFS NFBOT NVTU CF QSPWJEFE UP FOTVSF BEFRVBUF DPNCVTUJPO BJS GPS

these appliances. 

3.  How do I know if I need make-up air for my  

range hood?

In some cases the local building code may tell you that make-up air is 
necessary.  For example, some codes specify that range hoods with 

FYIBVTU GMPXT PG  DVCJD GFFU QFS NJOVUF  $'. PS IJHIFS OFFE B

mechanical system to introduce make-up air.
In other cases, make-up air for a range hood is desirable regardless of 
whether code requires it.  This is especially true for:

r MBSHFSSBOHFIPPET UIPTFPWFSDGN
r IPNFTXIJDIBSFXFMMBJSTFBMFETPPVUTJEFBJSNBZOPUCFBCMFUP

easily find its way into the home through cracks, to replace air which is 
exhausted out

r IPNFT XJUI BUNPTQIFSJDBMMZ WFOUFE DPNCVTUJPO BQQMJBODFT

(i.e. a water heater or natural draft fireplace), which are more 
susceptible to improper venting if depressurization occurs in 
the home.

In homes with any one of these factors make-up air is advised.  And in 
homes with more than one of these conditions make-up air for the range 
hood is strongly advised.

4.  What are the benefits of providing make-up air to replace air 

which is exhausted out of the home by a range hood?

Range hoods are designed to pull out pollutants like cooking odors or 
moisture at the source, so they don’t linger in the home.  Because these 

GBOTQVMMBJSPVUPGUIFIPVTFUIJTBJSOFFETUPCFSFQMBDFEXJUIiOFXuBJS

from outdoors.  Normally this make-up air enters the home through cracks 

BOEIPMFTJOUIFiTIFMMuPGUIFCVJMEJOH#VUNPEFSOIPNFTBSFBJSTFBMFE

much more thoroughly so there are not as many cracks and openings.  
Plus some exhaust fans like range hoods exhaust a lot more air than can 
be replaced through normal cracks in the building shell.
By providing an intentionally designed opening for fresh air to replace 
air which is exhausted out by the range hood, several important benefits 
result:

r 5IFNBLFVQBJSFOUFSJOHUIFIPNFDPNFTJOBUBLOPXOQPJOUXIFSF

it is also filtered

r /FHBUJWFQSFTTVSFDPOEJUJPOTXIJDIDPVMEBSJTFJGBJSJTFYIBVTUFEGSPN

a home without being replaced by new fresh air, are prevented

r 1PMMVUBOUTBSFNPSFFGGFDUJWFMZFYIBVTUFEGSPNUIFIPNFXIJMFGSFTI

replacement air is drawn into the home, improving ventilation

5.  Does ASHRAE 62.2-2007 – “Ventilation and Acceptable Indoor 

Air Quality in Low-Rise Residential Buildings” – require the use 
of a make-up air damper?

ASHRAE 62.2-2007 does not specifically require make-up air dampers. In 
a few limited circumstances, this standard does require that net exhaust 
flows from a house be limited.  For example, Section 6.4 of the standard 
limits the net exhaust flow from a home’s two largest exhaust appliances 
if the home has atmospherically vented or solid-fuel burning appliances 
located within the pressure boundary of the house. This standard is 
available at www.ashrae.org. 

6.  Can I use the Broan Automatic Make-Up Air Damper with other 

equipment in my home?  

/P5IF #SPBO"VUPNBUJD .BLF6Q"JS %BNQFS NBZ POMZ CF VTFE XJUI
DPNQBUJCMF#&45#SPBO&MJUFPS#SPBOSBOHFIPPET.PSFJOGPSNBUJPOPO

exact models of the Damper and compatible exhaust devices can be found 

JOUIF#SPBO"VUPNBUJD.BLF6Q"JS%BNQFS"QQMJDBUJPO(VJEF

7.  What are the different ways that the Damper can be installed in 

my home?  

The most common way to install the Damper is to connect it to a home’s 
central duct system.  In this application, outside fresh air enters the home 
through the Damper and is then routed and distributed through the home’s 

EVDUT.PSFJOGPSNBUJPOPOUIJTJOTUBMMBUJPOBQQSPBDIDBOCFGPVOEJOUIF
#SPBO"VUPNBUJD.BLF6Q"JS%BNQFS"QQMJDBUJPO(VJEFPOPVSXFCTJUF

www.broan.com.

 8IBUJGNZIPNFEPFTOUIBWFEVDUT 

Homes without ducts can still utilize the Damper to help replace air which 
is exhausted from the home by the range hood.  An installation illustration 

GPSUIJTTJUVBUJPOJTJODMVEFEJOUIF#SPBO"VUPNBUJD.BLF6Q"JS%BNQFS

Application Guide on our web site: www.broan.com.

9.  What happens after a power outage?

The Damper system and the associated exhaust devices will not lose their 
settings following a power outage.  So the system will resume its normal 
operation following a power outage, based on the settings it used prior to 
the outage.

99044953B

Regular maintenance is necessary to ensure the proper operation 
of the Damper system.  Failure to conduct such routine maintenance 
can jeopardize the ability of the Damper to introduce fresh air into the 
home.  Regular maintenance should include the following activities:

r $MFBOUIFPVUTJEFCJSETDSFFOUPFOTVSFJUJTGSFFGSPNEFCSJTBOE

open to allow fresh air to enter.

r $MFBOPSSFQMBDFUIFJOUFSJPSGJMUFS TXIJDITFSWFUPGJMUFSGSFTIBJS

before it enters the home.

r .BJOUBJOBDMFBSPQFOJOHBUUIFPVUEPPSFOEDBQXIJDINFBOTQSF

-

venting the buildup of snow, leaves, or vegetation at the end cap.

r %VSJOHSFHVMBS)7"$NBJOUFOBODFIBWFUIFNFDIBOJDBMDPOUSBD

-

tor inspect the Damper system for proper operation.

MAINTENANCE

Summary of Contents for MD6TU

Page 1: ...o not run the outside air duct directly above or closer than 2 ft to any furnace or its supply plenum boiler or other heat producing appliance 4 Any ductwork used in conjunction with the Damper must be installed in compliance with all local and national codes that are applicable 5 Do not operate the Damper for fresh air introduction until all system filters including the central duct system filter...

Page 2: ...in exterior walls including steps to prevent moisture intrusion around the opening Note that the screen over the outside air opening is not a filter It is intended to prevent the intake of leaves animals or debris into the out side air duct A downstream filter is necessary to remove pollen dust and other airborne particles Potential filter locations are shown below in the Typical Installations sec...

Page 3: ...s used Use the following illustrations and notes as guidance for your own installation Always comply with local code requirements and in any instance where a detail shown below conflicts with local code the local code provision shall apply Damper connected to return side of central duct system AIR HANDLER UNIT COOLING APPARATUS AIR DISTRIBUTION FAN HEATING APPARATUS THERMOSTAT CENTRAL SYSTEM SUPPL...

Page 4: ...hen the static QSFTTVSF JODSFBTFT UP u 1T PS NPSF U NBZ OPU PQFSBUF BU MPX speeds since the pressure is below this limit MULTIPLE DAMPERS PSF UIBO POF EBNQFS NBZ CF SFRVJSFE UP CBMBODF UIF TZTUFN G NPSF UIBO POF JT SFRVJSFE VTF 56 PS 56 BOE UIFO VTF UIF PS EBNQFST BT BEEJUJPOBM EBNQFST INSTALLATION OF PRESSURE SWITCH AND PROBE For the probe pressure switch to work effectively the roof or wall cap ...

Page 5: ... EXHAUST DUCT PRESSURE SWITCH HOOD FLUE ROOF CAP w DAMPER INLINE BLOWER TYPICAL INSTALLATION WITH EXTERIOR BLOWER RANGE HOOD PROBE EXHAUST DUCT PRESSURE SWITCH HOOD FLUE EXTERIOR BLOWER The probe must be mounted between the range hood damper and the wall cap roof cap in line blower or external blower PVOU UIF QSPCF BT DMPTF UP UIF IPPE PVUMFU BT QPTTJCMF CVU make sure the hood damper operation is ...

Page 6: ...RESSURE SWITCH PRESSURE SWITCH TUBING PROBE air flow arrow pointing in direction of air flow AIR FLOW DUCTWORK GASKET SHEET METAL SCREWS Connect tubing onto outside of black fitting Drill 3 8 HOLE in ducting 1 4 SPADE TERMINALS Probe opening pointing down AIR FLOW LOW VOLTAGE WIRES TUBE CONNECTED TO GREY INLET PRESSURE SWITCH SET UP FOR EXTERNAL IN LINE BLOWERS 1 4 SPADE TERMINALS Probe opening po...

Page 7: ...F EBNQFS PQFOT Turn off the hood and check to see if the damper closes A qualified HVAC contractor should also ensure the proper operation and venting of all combustion equipment in the home Wire the system as shown FALSE TRIPPING Under certain extreme conditions there could be false tripping of the damper opening when the range hood blower is off If false tripping JT FODPVOUFSFE QMBDF BO JO MJOF ...

Page 8: ...IF CVJMEJOH VU NPEFSO IPNFT BSF BJS TFBMFE much more thoroughly so there are not as many cracks and openings Plus some exhaust fans like range hoods exhaust a lot more air than can be replaced through normal cracks in the building shell By providing an intentionally designed opening for fresh air to replace air which is exhausted out by the range hood several important benefits result r 5IF NBLF V...

Page 9: ...ectement de l extérieur 3 Ne placez pas le conduit d arrivée d air extérieur directement au dessus d un appareil de chauffage d un caisson de distribution ou d une chaudière ni à moins de 60 cm 2 pi 4 Installez tout conduit utilisé avec le clapet conformément aux codes locaux et nationaux en vigueur 5 N utilisez pas le clapet pour introduire de l air frais tant que les filtres et notamment le filt...

Page 10: ...les mesures à prendre pour empêcher l entrée d humidité autour de l ouverture Veuillez noter que le grillage de la prise d air ne constitue pas un filtre Il ne vise qu à empêcher l entrée des feuilles des animaux ou des débris dans le conduit Un filtre situé en aval est nécessaire pour enlever le pollen la poussière et les autres particules en suspension Les emplacements possibles du filtre sont i...

Page 11: ... notes ci dessous pour vous guider dans l installation Respectez toujours les exigences des codes dans toute situation où un détail indiqué ci dessous contredirait les codes locaux Ceux ci ont préséance Clapet raccordé à la section de retour d air du conduit central APPAREIL DE TRAITEMENT DE L AIR REFROIDISSEUR VENTILATEUR DE DISTRIBUTION D AIR APPAREIL DE CHAUFFAGE THERMOSTAT DISTRIBUTION D AIR D...

Page 12: ...ression est inférieure à ce seuil CLAPETS MULTIPLES Plusieurs clapets peuvent être nécessaires pour équilibrer le système Si vous utilisez plusieurs clapets choisissez un 1 DMBQFU 56 PV 56 QVJT VUJMJTF MFT NPEÍMFT PV DPNNF DMBQFUT BEEJUJPOOFMT INSTALLATION DU MANOCONTACTEUR ET DE LA SONDE Pourquelasondeetlemanocontacteurfonctionnentcorrectement le capuchon mural ou de toit doit avoir un clapet à r...

Page 13: ...tallation HOTTE DE CUISINIÈRE SONDE CONDUIT D ÉVACUATION CAPUCHON DE TOIT ET CLAPET MANOCONTACTEUR CONDUIT DE LA HOTTE INSTALLATION TYPE AVEC VENTILATEUR INTERNE ET ÉVENT DE TOIT CLAPET SUR CONDUIT INSTALLATION TYPE AVEC VENTILATEUR INTERNE ET CONDUIT HORIZONTAL AVEC ÉVENT MURAL HOTTE DE CUISINIÈRE CAPUCHON MURAL ET CLAPET SONDE TUBE MANOCONTACTEUR ARMOIRE DE CUISINE INSTALLATION TYPE AVEC VENTILA...

Page 14: ...AIR FILS DE BASSE TENSION Ouverture de la sonde tournée vers le bas COSSES OUVERTES DE 1 4 PO FILS DE BASSE TENSION TUBE CONNECTÉ À L ENTRÉE GRIS CONDUIT HORIZONTAL MANOCONTACTEUR TUBE SONDE la flèche pointe dans le sens du débit d air DÉBIT D AIR CONDUIT CONDUIT VERTICAL MANOCONTACTEUR TUBE SONDE la flèche pointe dans le sens du débit d air DÉBIT D AIR CONDUIT MANOCONTACTEUR TUBE SONDE la flèche ...

Page 15: ...fage et de climatisation doit également s assurer du bon fonctionnement de tout appareil de combustion notamment l évacuation des gaz de combustion Effectuez le câblage tel qu illustré 24V 20V BORNES 24V CÂBLAGE DUTRANSFORMATEUR DÉCLENCHEMENT INDÉSIRABLE Dans certaines conditions extrêmes le clapet peut se déclencher alors qu il ne le devrait pas s ouvre alors que la hotte est arrêtée Si un tel dé...

Page 16: ... d ouvertures De plus certains ventilateurs comme ceux des grandes hottes évacuent beaucoup plus d air que celui pouvant être remplacé par les fentes et les fissures de l enceinte de la maison Le fait de créer délibérément un passage pour l air frais afin de remplacer l air évacué par la hotte présente plusieurs avantages importants r BJS EF DPNQFOTBUJPO RVJ QÊOÍUSF EBOT MB NBJTPO MF GBJU Æ VO end...

Page 17: ...s de vivienda adyacentes u otros sitios dentro de la estructura del edificio La unidad deberá instalarse de tal manera que introduzca el aire directo del exterior 3 No tienda el conducto de aire exterior directamente arriba o más cerca de 2 pies 60 cm de cualquier caldera o su pleno de suministro calentador u otro aparato que genere calor 4 Cualquier conducto que se utilice en conjunto con el regu...

Page 18: ...s paredes exteriores incluyendo pasos para prevenir que entre humedad alrededor de la abertura Tomeencuentaquelamallasobrelaaberturadeaireexteriornoesunfiltro Está diseñada para prevenir la entrada de hojas animales o desperdicios al conducto de aire exterior Es necesario contar flujo hacia abajo con un filtro para extraer polen polvo y otras partículas transportadas por el aire Las posibles ubica...

Page 19: ...ara su propia instalación Siempre cumpla con los requisitos de los códigos locales y en cualquier caso donde alguno de los detalles que se muestran a continuación tenga conflicto con los códigos locales se aplicará la disposición del código local Regulador conectado al lado de retorno del sistema de conducto central UNIDAD DE MANEJO DE AIRE APARATO DE ENFRIAMIENTO VENTILADOR DE DISTRIBUCIÓN DE AIR...

Page 20: ... presión está por debajo de este límite MÚLTIPLES REGULADORES Tal vez se requiera más de un regulador para equilibrar el sistema 4J TF SFRVJFSF NÃT EF VOP VTF 56 P 56 Z MVFHP VTF MPT SFHVMBEPSFT P DPNP SFHVMBEPSFT BEJDJPOBMFT INSTALACIÓN DEL INTERRUPTOR DE PRESIÓN Y SONDA Para que la sonda y el interruptor de presión funcionen con eficacia la tapa para techo o pared debe tener un regulador cargado...

Page 21: ... ESTUFA SONDA CONDUCTO DE EXTRACCIÓN TAPA DE TECHO c REGULADOR INTERRUPTOR DE PRESIÓN TUBO DE HUMOS DE LA CAMPANA INSTALACIÓN TÍPICA CON VENTILADOR INTERNO Y VENTILACIÓN DE TECHO REGULADOR EN LÍNEA INSTALACIÓN TÍPICA CON VENTILADOR INTERNO Y CONDUCTOS HORIZONTALES CON VENTILACIÓN DE PARED CAMPANA DE ESTUFA TAPA DE PARED c REGULADOR SONDA TUBERÍA INTERRUPTOR DE PRESIÓN GABINETE DE COCINA INSTALACIÓ...

Page 22: ...ha del flujo de aire apunta en dirección del flujo de aire FLUJO DE AIRE CONDUCTO EMPAQUE TORNILLOS PARA CHAPA METÁLICA Conecte el tubo por fuerade la unión negra Perfore un orificio de 9 5 mm 3 8 pulg en el conducto CONFIGURACIÓN DEL INTERRUPTOR DE PRESIÓN PARA VENTILADORES EXTERNA Y EN LÍNEA TUBO CONECTADO A LA ENTRADA NEGRA CONFIGURACIÓN DEL INTERRUPTOR DE PRESIÓN PARA VENTILADORES INTERNOS TER...

Page 23: ...egulador Un contratista calificado en HVAC también debe asegurarse la operación adecuada y la ventilación de todo el equipo de combustión en la casa Cablee el sistema como se ilustra 24V 20V CONTACTOS DE 24 V CABLEADO DELTRANSFORMADOR DISPARO EN FALSO Bajo ciertas condiciones extremas podría haber el disparo en falso del regulador se abre cuando el ventilador de la campana está apagado Si se encue...

Page 24: ...el aire así que no hay tantas grietas y aberturas Además algunos ventiladores de extracción como los de las campanas extraen mucho más aire del que se puede reemplazar a través de las grietas normales de la armazón del edificio Al suministrar una abertura diseñada intencionalmente para que el aire fresco reemplaceelaireextraídoporlacampana resultanvariosbeneficiosimportantes r M BJSF EF SFQVFTUP R...

Reviews: