TYPICAL INSTALLATION

MOUNTING

(New Frame Construction)

CEILING  JOIST

[24” (609.6 mm)

centers shown]

10” (254 mm)

ROUND DUCT

Factory-shipped unit installed in new construction.

MOUNTING

SCREW

Blower factory-shipped

in horizontal

discharge position.

Mounting brackets

factory-shipped in

position for ½”

(12.7 mm) ceiling

material.

MOUNTING

(Existing Frame Construction)

Factory-shipped unit installed in existing construction.

TYPICAL INSTALLATION

WIRING

WIRING

PLATE

WHITE

TO

WHITE

BLACK

TO

BLACK

TOP / BACK

OF HOUSING

120 VAC LINE IN

GROUND TO

WIRING PLATE

10” (254 mm)

ROUND DUCT

FINISHED

CEILING

MATERIAL

CEILING JOIST

[24” (609.6 mm)

centers shown]

2 X 4 FRAMING

(wide side down)

MOUNTING

BRACKETS

(Attached to

opposite sides

of housing &

upside-down,

so housing is

flush with

finished ceiling)

DUCTING

(Straight-through blower discharge)

Two ways to connect ductwork to a factory-shipped unit.

Ventilator can be wired from outside of housing.

Use UL approved connectors to wire per local codes.

ROOF CAP

10” (254 mm)

ROUND

ELBOW

10” (254 mm)

ROUND DUCT

WALL

CAP

NOTE: Make sure the shipping tape is removed from the damper

flap and that damper flap opens and closes freely inside the

ductwork. Use duct tape to make ductwork connections secure and

air-tight.

4½” (114.3 mm) X

18½” (469.9 mm)

TO 10” (254 mm)

ROUND TRANSITION

MOUNTING

SCREW

4½” (114.3 mm) X

18½” (469.9 mm)

TO 10” (254 mm)

ROUND

TRANSITION

4½” (114.3 mm) X

18½” (469.9 mm)

TO 10” (254 mm)

ROUND TRANSITION

4½” (114.3 mm) X

18½” (469.9 mm)

TO 10” (254 mm)

ROUND TRANSITION

10” (254 mm)

ROUND DUCT

4½” (114.3 mm) X

18½” (469.9 mm) TO

10” (254 mm)

ROUND TRANSITION

10” (254 mm)

ROUND DUCT

10” (254 mm)

ROUND DUCT

®

MODELS

L400KL • L500KL

Summary of Contents for Losone Select L400KL

Page 1: ...r leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings 2 Always turn hood ON when cooking at high he...

Page 2: ...sides of housing upside down so housing is flush with finished ceiling DUCTING Straight through blower discharge Two ways to connect ductwork to a factory shipped unit Ventilator can be wired from ou...

Page 3: ...connector in straight through dis charge position Factory shipped BLOWER Change blower duct connector positions for right angle discharge DUCTING Right angle blower discharge Typical ductwork connecti...

Page 4: ...ING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone Canada will at its option repair or replace without charge any...

Page 5: ...a n c ed e su n i t sd es u r f a c er g l e s f e uv i f E np l u sd e g n r e rd el af u m e l e sd b o r d e m e n t sd eg r a i s s ep e u v e n tp r e n d r ef e u C h a u f f e rl e s h u i l e...

Page 6: ...ION DES CONDUITS d charge de soufflerie dans ligne Deux mani res de raccorder les conduits un appareil pr mont Le ventilateur peut tre branch depuis l ext rieur du bo tier Utiliser des connecteurs hom...

Page 7: ...U C BLE D ALIMENTATION LA VERTICALE Raccord de soufflerie et de conduit en position de d charge dans ligne pr assembl e RACCORD DE CONDUIT Raccord de soufflerie et de conduit en position de d charge d...

Page 8: ...N PAS LIMIT AUX GARANTIES IMPLICITES POUR FIN DE COMMERCIALISATION ET DE CONVENANCE DANS UN BUT PARTICULIER Pendant cette p riode d un an Broan NuTone Canada son choix r parera ou remplacera gratuitem...

Reviews: