background image

Page 2

LOSONE SELECT

®

 L100 SERIES   L150 SERIES

L200 SERIES    L250 SERIES   L300 SERIES  

TYPICAL INSTALLATION

MOUNTING 

(New Frame Construction)

CEILING JOIST

(16” centers shown)

ROUND DUCT*

GRILLE

(Polymeric

shown)

Install after

ceiling is

finished.

Factory-shipped unit installed in new construction.

MOUNTING

SCREW

GRILLE

SCREW

Blower factory-shipped

in horizontal

discharge position.

Mounting brackets 

factory-shipped in 

position for ½” ceil-

ing material.

ADDITIONAL

1½” FRAMING

MOUNTING 

(Existing Frame Construction)

Factory-shipped unit installed in existing construction.

TYPICAL INSTALLATION

WIRING

WIRING

PLATE

WHITE

TO

WHITE

BLACK

TO

BLACK

TOP / BACK

OF HOUSING

LINE IN

GROUND TO

WIRING PLATE

ROUND DUCT*

GRILLE

SCREW

FINISHED

CEILING

MATERIAL

GRILLE

(Polymeric shown)

CEILING JOIST

(16” centers

shown)

2 X 4 FRAMING

(wide side down)

MOUNTING

BRACKETS

(Attached to

opposite sides

of housing & up-

side-down,

so housing is

flush with

finished ceiling)

DUCTING 

(Horizontal blower discharge)

Two ways to connect ductwork to a factory-shipped unit.

Ventilator can be wired from outside of housing.

Use UL approved connectors to wire per local codes.

ROOF CAP

ROUND

ELBOW*

ROUND

DUCT*

WALL

CAP

IMPORTANT:

Remove shipping tape from damper

Remove the shipping tape from the damper flap and make sure that 

damper flap opens and closes freely inside the ductwork. Use duct 

tape to make ductwork connections secure and air-tight.

Remove shipping ring from blower inlet

Remove the shipping ring from the blower inlet before operating 

the ventilator.

* L100 & L150 Series uses 6” Round Duct.
  L200, L250, & L300 Series uses 8” Round Duct.

* L100 & L150 Series uses 6” Round Duct.
  L200, L250, & L300 Series uses 8” Round Duct.

Summary of Contents for L250 Series

Page 1: ...EXCLUDES ALL OTHER EXPRESS WARRANTIES AND DISCLAIMS AND EXCLUDES ALL WARRANTIES IMPLIED BY LAW INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE To the extent...

Page 2: ...GRILLE Polymeric shown CEILING JOIST 16 centers shown 2 X 4 FRAMING wide side down MOUNTING BRACKETS Attached to opposite sides of housing up side down so housing is flush with finished ceiling DUCTI...

Page 3: ...N Wiring plate mounts to side or top of housing HORIZONTAL POWER CABLE CONNECTION VERTICAL POWER CABLE CONNECTION Blower and duct connec tor in horizontal discharge position Factory shipped DUCT CONNE...

Page 4: ...L300C 99080503 Motor L100EX 99080504 Motor L150EX 99080505 Motor L200EX 99080506 Motor L250EX 99080507 Motor L300EX 13 99260558 Lock Nut 8 32 4 req 14 99250959 Washer 4 req 15 99100491 Grommet 4 req...

Page 5: ...ene la nica obligaci n de la Compa a y su nico recurso ante productos defectuosos Las garant as anteriores son exclusivas y en lugar de cualquier otra garant a expresa o impl cita LA COMPA A NIEGA Y E...

Page 6: ...opuestos del alojamiento y hacia abajo para que el alojamiento quede a nivel del cielo raso terminado COLOCACI N DE CONDUCTOS descarga hori zontal del ventilador Dos formas de conectar los conductos...

Page 7: ...EXI N VERTICAL DEL CABLE DE ALI MENTACI N Cambie la posici n del conector del ventilador y del conducto para una descarga vertical Conector del ventilador y del conducto en posici n de descarga horizo...

Page 8: ...0C 99080497 Motor L300C 99080503 Motor L100EX 99080504 Motor L150EX 99080505 Motor L200EX 99080506 Motor L250EX 99080507 Motor L300EX 13 99260558 Tuercas de 8 32 se req 4 14 99250959 Arandelas se req...

Page 9: ...toris s par la Soci t La pr sente garantie remplace toute garantie pr c dente et le consommateur et acheteur initial ne peut la c der quiconque Aucune autre garantie La pr sente garantie limit e stipu...

Page 10: ...ni INSTALLATION DES CONDUITS d charge de soufflerie horizontale Deux mani res de raccorder les conduits un appareil pr mont Le ventilateur peut tre branch depuis l ext rieur du bo tier Utiliser des co...

Page 11: ...DE TOIT AVERTISSEMENT Pour diminuer les risques de d charge lectrique d brancher la source d alimentation avant toute op ration d entretien Pour nettoyer la grille Utiliser un accessoire d aspirateur...

Page 12: ...oteur L150EX 99080505 Moteur L200EX 99080506 Moteur L250EX 99080507 Moteur L300EX 13 99260558 crou 8 32 4 oblig 14 99250959 Rondelle 4 oblig 15 99100491 Bague d toupe 4 oblig 9 15 Soufflerie ensemble...

Reviews: