background image

INST

ALLA

TION 

AND USE & CARE INSTR

UCTIONS

INST

ALLA

TION

5

5.  Connect 4-in. round duct.

6.  Connect wiring.

Bend tab to expose desired access hole. Connect 

power cable to housing with appropriate UL approved 

connector. Connect wires per diagram on page 8. Re-

install wiring panel and secure with screw from parts 

bag.

3.  Attach damper/duct connector 

to fan housing.

Push connector through opening from inside of housing. 

Engage tabs and secure with screw from parts bag.

4.  Mount housing to ceiling 

structure.

TABS

Make sure bottom of housing will be flush with finished 

ceiling.
For proper location using ½-inch ceiling material: Bend 

out housing tabs to fit against bottom of structure.
Secure housing through mounting ears with 

appropriate fasteners.
If mounting housing to I-joist, use wood blocking as 

shown.

NEW CONSTRUCTION

For Retrofit Installation - Skip to Page 6. 

HOUSING 

TABS

Summary of Contents for InVent 80 CFM Series

Page 1: ...y Sensing Fan Light Ventilador L mpara con sensor de humedad AE80SL AE110SL Model numbers N meros de modelo INSTALLATION AND USE CARE INSTRUCTIONS INSTRUCCIONES PARA INSTALACI N USO Y CUIDADO English...

Page 2: ...PA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring...

Page 3: ...ch back ON and fan will turn ON 50 60 80 70 10 5 60 15 40 20 30 50 HUMIDITY MINUTES HUMIDITY ADJUSTMENT HUMIDITY has been factory set at 80 for most shower applications If fan is not responding to cha...

Page 4: ...ing POWER CABLE Purchase separately OR Keep duct runs short 4 IN ROUND DUCT ALL INSTALLATIONS Start here IMPORTANT The ducting from this fan to the outside of the building has a strong effect on the a...

Page 5: ...ector to fan housing Push connector through opening from inside of housing Engage tabs and secure with screw from parts bag 4 Mount housing to ceiling structure TABS Make sure bottom of housing will b...

Page 6: ...Make sure that the wiring inside of the housing does not interfere with re installation of the blower 8 Install housing mask Place mask into housing opening to prevent drywall spray and construction d...

Page 7: ...connector Push connector ducting back through opening Engage tabs and secure with screw from parts bag 1 2 3 Install blower Finish ceiling then install grille See Steps 7 8 9 on Page 6 Step 8 is only...

Page 8: ...5 97019785 97019786 Blower Assembly AE80SL Blower Assembly AE110SL 6 99271529 LED Module 7 99140214 Grille Spring 2 req 8 97019920 Grille Assembly includes key no 6 7 97019743 Parts Bag not shown BLK...

Reviews: