3. MAINTENANCE (

CONT

D

)

3.3 A

NNUAL

 

MAINTENANCE

 (F

ALL

)

Repeat steps 1 to 6 from the Section 3.1 and continue with the following steps:

1.  Clean the heat recovery core:

 • Remove 

core.

 

• 

Let it soak in a mixture of cold or lukewarm water and mild soap (dishwashing liquid).

 • Rinse 

thoroughly.

 

• 

Shake the core to remove excess water and let it dry.

2.  Clean blower assembly.

 

• 

Remove dust using a vacuum cleaner with a soft brush attachment.

3.  Reassemble the components.

4.  Reconnect power supply.

CAUTION

Hot water and a strong detergent will damage the heat recovery core.

3.3.1 H

EAT

 

RECOVERY

 

CORE

Repeat steps 1 to 6 from the Section 3.1 and continue with the following steps:

1.  Clean the energy recovery core:

 • Remove 

core.

 

• 

Remove dust using a vacuum cleaner with a soft brush attachment.

2.  Clean blower assembly.

 

• 

Remove dust using a vacuum cleaner with a soft brush attachment.

3.  Reassemble the components.

4.  Reconnect power supply.

CAUTION

The energy recovery core cannot be washed with water.

3.3.2 E

NERGY

 

RECOVERY

 

CORE

Summary of Contents for HRV150S

Page 1: ...LER 22644 REV 03 ERV180S HRV150S VB0297 HRV190S READ AND SAVE THESE INSTRUCTIONS Broan NuTone LLC Hartford Wisconsin www broan com 1 877 862 7626 REGISTER YOUR PRODUCT ONLINE AT www broan com register...

Page 2: ...including possibility of death Denotes an instruction which if not followed may severely damage the unit and or its components WARNING Some activities create dust or vapors which may damage your unit...

Page 3: ...or temperature is below 23 F recovery of heat or energy creates frost in the module To maintain its proper operation the unit is programmed to defrost the recovery module The defrost frequency varies...

Page 4: ...control LED will light GREEN or AMBER for 5 seconds and then will shut off for 2 seconds After that the LED will light RED for the rest of the booting sequence During this RED light phase the unit is...

Page 5: ...NTHS Regular maintenance should be performed every 3 months Annual maintenance should take place every Fall season 1 Disconnect power supply 2 Unlatch the door Lift the panel towards you Hold it firml...

Page 6: ...erior air intake hood Make sure there are no leaves twigs ice or snow that could be drawn into the vent Clean if necessary 7 Reassemble the components 8 Reconnect power supply CAUTION Even a partial b...

Page 7: ...soft brush attachment 3 Reassemble the components 4 Reconnect power supply CAUTION Hot water and a strong detergent will damage the heat recovery core 3 3 1 HEAT RECOVERY CORE Repeat steps 1 to 6 from...

Page 8: ...s are not blocked Operate the unit at low speed Have the system s balancing checked Have the unit s defrost system checked Install a duct heater For wall controls problems refer to the Troubleshooting...

Reviews: