7
2. PREPARE THE INSTALLATION (
CONT’D
)
Cut-out the openings for duct (
A
) and power cable (
B
), in cabinet or wall, according to the direction of discharge chosen.
See figures below.
NOTE: For all internal blower hoods, the cut-out opening for house wiring can be made in cabinet bottom OR wall, no matter the
discharge chosen (vertical or horizontal).
3. INSTALL BACKSPLASH (OPTIONAL)
Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order to be able
to install the backsplash, make sure you have at least 18" clearance between bottom of hood and range control panel or cooktop. (See
instructions packed with backsplash.)
L
C
CABINET BOTTOM VIEW
22”
10”
10”
INTERNAL DOUBLE BLOWER HOOD
HD0656A
L
C
B
CABINET BOTTOM VIEW
5¼”
5¼”
3¾”
A
INTERNAL SINGLE BLOWER HOOD
L
C
INTERNAL SINGLE BLOWER HOOD
2”
B
3¾”
5¼”
5¼”
A
L
C
22”
INTERNAL DOUBLE BLOWER HOOD
5½”
10”
10”
7/8”
5½”
3/4”
L
C
CABINET BOTTOM VIEW
5
7 8
”
HOOD WITH IN-LINE OR EXTERIOR BLOWER
3½”
4
7 8
”
B
A
Ø 10½”
10¼ ”
B
A
C
C
2”
2”
B
A
2”
2”
2”
2”
2”
9³
8
”
CABINET CENTER LINE
5/8”
1/4”
3/8”
H
OOD
W
IDTHS
D
IMENSION
C
30"
13"
36"
16"
42"
19"
48"
22"
V
ERTICAL
DISCHARGE
H
OOD
W
IDTHS
D
IMENSION
C
30"
13"
36"
16"
42"
19"
48"
22"
H
ORIZONTAL
DISCHARGE
V
ERTICAL
DISCHARGE
ONLY