background image

7

3.  PREPARE THE INSTALLATION (

CONT’D

)

Cut-out the openings for duct (

A

) and power cable (

B

), in cabinet or wall, according to the direction of discharge chosen.

See figures below.

NOTE:   For all internal blower hoods, the cut-out opening for house wiring can be made in cabinet bottom OR wall, no matter the 
 

discharge chosen (vertical or horizontal).

4.  INSTALL BACKSPLASH (

OPTIONAL

)

(Optional) 

RMP Series

Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order to be able 
to install the backsplash, make sure you have at least 18’’ clearance between bottom of hood and range control panel or cooktop. (See 
instructions packed with backsplash.)

L

C

CABINET BOTTOM VIEW

22”

10”

10”

INTERNAL DOUBLE BLOWER HOOD

HD0266A

L

C

B

CABINET BOTTOM VIEW

5¼”

5¼”

3¾”

A

INTERNAL SINGLE BLOWER HOOD

L

C

INTERNAL SINGLE BLOWER HOOD

2”

B

3¾”

5¼”

5¼”

A

L

C

22”

INTERNAL DOUBLE BLOWER HOOD

5½”

10”

10”

7/8”

5½”

B

A

9

1 8

C

C

2”

2”

B

2”

2”

2”

2”

2”

8

3 8

1/2”

H

OOD

 W

IDTHS

D

IMENSION

 

C

30"

13"

36"

16"

42"

19"

48"

22"

V

ERTICAL

 

DISCHARGE

H

OOD

 W

IDTHS

D

IMENSION

 

C

30"

13"

36"

16"

42"

19"

48"

22"

H

ORIZONTAL

 

DISCHARGE

L

C

CABINET BOTTOM VIEW

5

7 8

HOOD WITH IN-LINE OR EXTERIOR BLOWER

3½”

4

7 8

B

A

Ø 10½”

10¼ ”

8

CABINET CENTER LINE

HD0286A

L

C

9¾”

HOOD WITH IN-LINE OR EXTERIOR BLOWER

9¾”

A

Ø 10½”

5

  ³

8

4

7

8

3½”

B

3/8”

Summary of Contents for E60000LC SERIES

Page 1: ...C COOKING ONLY INSTALLER LEAVE THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 13 14 READ AND SAVE THESE INSTRUCTIONS Venmar Ventilation ULC Drummondville Qu bec www broan ca 87...

Page 2: ...g use only Do not use to exhaust hazardous or explosive materials and vapors 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power un...

Page 3: ...0 ROUND HORIZ LEFT OPTIONAL DECORATIVE FLUE AEE SERIES ADAPTER 4 X 18 SUPPLIED WITH DOUBLE BLOWER HOOD DUAL BLOWER 1200 CFM 36 42 AND 48 ONLY E60000LC SERIES HOOD RMP SERIES BACKSPLASH STAINLESS STEEL...

Page 4: ...NS MODEL HLB9 800 CFM OR HLB11 1100 CFM IN LINE BLOWER INCLUDES TWO 8 X 12 TO 10 ROUND TRANSITIONS MODEL 441 10 ROUND WALL CAP MODEL 331H 600 CFM OR 332H 900 CFM EXTERIOR BLOWER MODEL 335 1200 CFM OR...

Page 5: ...d follow steps 1 2 3 4 6 10 and up of this manual Install proper sized ductwork elbows and roof or wall cap for the type of blower you are installing If using 7 8 or 10 round ducts use a transition in...

Page 6: ...are included Wood strip attached to back of hood Accessories including Baffle filters with handles 30 and 36 hoods come with 3 baffle filters 42 and 48 hoods come with 4 baffle filters 3 x 10 adapter...

Page 7: ...the backsplash make sure you have at least 18 clearance between bottom of hood and range control panel or cooktop See instructions packed with backsplash L C CABINET BOTTOM VIEW 22 10 10 INTERNAL DOU...

Page 8: ...the middle one s B Lift out grease drip rail 1 and set aside 5 CHOOSE THE OPENING S INTERNAL BLOWER S HOOD ONLY 6 REMOVE THE FILTERS AND THE GREASE DRIP RAIL 7 REMOVE THE ADAPTER INTERNAL BLOWER HOOD...

Page 9: ...plies for one or two blowers HD0269 LEFT SIDE MOUNTING SCREWS LOCATION Using a 5 16 socket remove all blower mounting screws from the inner top of the hood Keep the screws for further use HD0282 RIGHT...

Page 10: ...ropriate sized transition and seal the joints with metal foil duct tape HD0263A Measure and mark a level line on wall above cooktop location for the wood mounting strip see illustration at right and u...

Page 11: ...3 washers provided 12 INSTALL THE HOOD CAUTION Hold the hood until it is completely secured to the wood mounting strip HD0579 WALL ANCHORS LOCATION MOUNTING SCREWS LOCATION 13 ROUGH IN PLATE LOCATION...

Page 12: ...ration at right shows how to reinsert the grease drip rail into the range hood CAUTION Remove protective plastic film covering filters before installing them 1 HD0655 2 It is recommended to install si...

Page 13: ...Let plaster dust or any other construction residues reach the hood During construction renovation cover the hood to make sure no dust sticks to the stainless steel surfaces Avoid when choosing a dete...

Page 14: ...VENMAR VENTILATION ULC S OBLIGATION TO REPAIR OR REPLACE AT VENMAR VENTILATION ULC S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY VENMAR VENTILATION ULC SHALL NOT BE...

Page 15: ...IONAL SECOND BLOWER MOTOR HE0207A LED DRIVER LED LED BRN GRY LED CONTROL IN J1 J2 OUT WHT WHT SPEED CONTROL HEAT SENTRY THERMOSTAT BLU BLK BLK BLU GRY WHT BLK YEL BLK ORA NEON ORA M REMOTE BLOWER ASSE...

Page 16: ...E RAIL 42 GREASE RAIL 48 1 1 1 1 7 SV08337 BAFFLE FILTER SPRING SET OF 6 1 1 1 1 8 SV17606 SV17609 BAFFLE FILTER 8 84 x 15 125 BAFFLE FILTER 11 84 X 15 125 2 1 3 2 2 4 9 SV07680 BAFFLE FILTER HANDLE W...

Reviews: