background image

INST
ALLA
TION MANUAL

INST
ALLA

TION

13

Prepare the Hood Location

NOTE: Before starting installation, read all the steps of these instructions.
Use the illustration below to identify your kitchen cabinet type.

EZ1 One-person installation system

EZ1 installation is designed for use with kitchen cabinets that have the same width designation as 
the range hood width. If the cabinet is greater than 1/2” wider than the range hood width, please 
use the standard installation method.

1 ] 

Use the proper template for vertical OR horizontal disharge (included) for placement of 
ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a 
duct access hole, only cut the hole for electrical wiring. 

If replacing a hood and plan to use 

the existing duct and electrical, steps 2 to 5 may not be necessary. If so, skip to step 6.

2 ]  

Measure and mark the hood center line on cabinet bottom.

3 ]  

Align the center line on template with the hood center line marked on the bottom of the 
cabinet, placing the edge (where indicated) of the template against back wall. When using 
with framed cabinet for vertical exhaust installation, fold over rear edge of template equal 
to the depth of the cabinet frame at the wall (use graduations on template, 

C

 locations on 

template). Tape the template in place.

 

NOTE: When facing the installation, 

A

 and 

B

 (on template) must be at right.

CABINET FRONT

C

L

A

B

Apoyar este borde contra la pared de atrás

Place this edge against back wall

A

S

A

A

V

RTICAL EX

= 3¼” x 10”

= 3¼” x 14”

R

ECTANGULAR

 D

UCTING

7” R

OUND

 D

UCTING

OR

Use this template for marking;  do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.

= 3¼ po x 10 po

= 3¼ po x 14 po

C

ONDUIT

 

RECTANGULAIRE

C

ONDUIT

 

ROND

 

DE

 7 

PO

OU

= 3¼ pulg. x 10 pulg.

= 3¼ pulg. x 14 pulg.

C

ONDUCTO

 

RECTANGULAR

C

ONDUCTO

 

REDONDO

DE

 7 

PULG

.

O

Appuyer ce bord au mur arrière

Utiliser ce gabarit pour marquer vos repères;  ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l’installation; elles ne doivent pas
 

être du format exact des conduits.

Use esta plantilla para crear marcados;  no trate de cortar el
agujero del conducto a través de la plantilla.

NOTA: To be translated in Spanish.

M

ARK

 

WHERE

 

INDICATED

 

FOR

 

THE

 

APPROPRIATE

 

SIZE

 

DUCT

 

OPENING

M

ARQUER

 

LES

 

REPÈRES

 

AUX

 

ENDROITS

 

INDIQUÉS

 

SELON

 

LE

 

FORMAT

 

DE

 

CONDUIT

 

UTILISÉ

T

ITLE

 

TO

 

BE

 

TRANSLATED

 

IN

 S

PANISH

Electrical access hole center

A

 = single blower hood

B

 = double blower hood

Centre du trou pour fil
d’alimentation électrique

A

 = hotte ventilateur simple

B

 = hotte ventilateur double

To be translated in Spanish
Electrical access hole center

A

 = single blower hood

B

 = double blower hood

4¼”

10½”

14½”

8”

7½”

C

C

C

Bend template along graduated
scale when installing to framed
cabinet.

Pour une installation sous une
armoire à fond en retrait, utiliser les
lignes pour mesurer l’épaisseur du
décalage causé par le mur de 
l’armoire et plier le gabarit en 
conséquence.

To be translated in Spanish.

P

C

CABINET FRONT

C

L

A

B

VERTICAL EXHAUST

A

S

A

A

V

RTICAL EX

= 3¼” x 10”

= 3¼” x 14”

R

ECTANGULAR

 D

UCTING

7” R

OUND

 D

UCTING

OR

Use this template for marking;  do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.

= 3¼ po x 10 po

= 3¼ po x 14 po

C

ONDUIT

 

RECTANGULAIRE

C

ONDUIT

 

ROND

 

DE

 7 

PO

OU

= 3¼ pulg. x 10 pulg.

= 3¼ pulg. x 14 pulg.

C

ONDUCTO

 

RECTANGULAR

C

ONDUCTO

 

REDONDO

DE

 7 

PULG

.

O

Utiliser ce gabarit pour marquer vos repères;  ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l’installation; elles ne doivent pas
 

être du format exact des conduits.

Use esta plantilla para crear marcados;  no trate de cortar el
agujero del conducto a través de la plantilla.

NOTA: To be translated in Spanish.

M

ARK

 

WHERE

 

INDICATED

 

FOR

 

THE

 

APPROPRIATE

 

SIZE

 

DUCT

 

OPENING

M

ARQUER

 

LES

 

REPÈRES

 

AUX

 

ENDROITS

 

INDIQUÉS

 

SELON

 

LE

 

FORMAT

 

DE

 

CONDUIT

 

UTILISÉ

T

ITLE

 

TO

 

BE

 

TRANSLATED

 

IN

 S

PANISH

Electrical access hole center

A

 = single blower hood

B

 = double blower hood

Centre du trou pour fil
d’alimentation électrique

A

 = hotte ventilateur simple

B

 = hotte ventilateur double

To be translated in Spanish
Electrical access hole center

A

 = single blower hood

B

 = double blower hood

4¼”

10½”

14½”

8”

7½”

C

C

C

Bend template along graduated
scale when installing to framed
cabinet.

Pour une installation sous une
armoire à fond en retrait, utiliser les
lignes pour mesurer l’épaisseur du
décalage causé par le mur de 
l’armoire et plier le gabarit en 
conséquence.

To be translated in Spanish.

ELECTRICAL

ACCESS HOLE

LOCATION (

B

)

(

IN

 

CABINET

 

BOTTOM

)

CENTER LINE

F

OLD

 

TEMPLATE

 

ALONG

 

GRADUATED

SCALE

 

WHEN

 

INSTALLING

 

TO

 

FRAMED

CABINET

.

B

VERTICAL EXHAUST 

DUCTING

ELECTRICAL

ACCESS HOLE

LOCATION (

B

)

(

IN

 

WALL

)

CENTER LINE

C

L

A

B

Place this edge against
cabinet bottom.
Appuyer ce bord contre le bas
de l’armoire.
Apoyar este borde contra
la base del armario.

HORIZONTAL EXHAUST

T

T

= 3¼ pulg. x 10 pulg.
= 3¼ pulg. x 14 pulg.

CONDUCTO RECTANGULAR

= 3¼” x 10”
= 3¼” x 14”

RECTANGULAR DUCTING

= 3¼ po x 10 po
= 3¼ po x 14 po

CONDUIT RECTANGULAIRE

MARK WHERE INDICATED 

FOR

 THE APPROPRIATE SIZE DUCT OPENING

MARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON 

LE

 FORMAT DE CONDUIT UTILISÉ

TITLE TO BE TRANSLATED IN SPANISH

Use this template for marking;  do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.

Utiliser ce gabarit pour marquer vos repères;  ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l’installation; elles ne doivent pas
 

être du format exact des conduits.

Use esta plantilla para crear marcados;  no trate de cortar el
agujero del conducto a través de la plantilla.
NOTA: To be translated in Spanish.

Electrical access hole center

A

 = single blower hood

B

 = double blower hood

Centre du trou pour fil
d’alimentation électrique

A

 = hotte ventilateur simple

B

 = hotte ventilateur double

To be translated in Spanish
Electrical access hole center

A

 = single blower hood

B

 = double blower hood

B

ess hole center
wer hood
wer hood

HORIZONTAL EXHAUST 

DUCTING

This manual covers 2 kinds of installation: the standard (without EZ1 brackets) 
and the EZ1 one-person installation system (using included template and brackets).
For the standard installation, go to page 18.

FRAMED CABINET

FRAMELESS CABINET

Summary of Contents for BCDJ Series

Page 1: ...WWW BROAN COM Serial number 99045652 105B WWW BROAN CA RANGE HOOD Series BCDJ and NCDJ INSTALLATION USE AND CARE MANUAL WWW NUTONE CA ...

Page 2: ...Installation 8 20 Recommended Tools and Accessories for Installation 8 Install Ductwork Ducted Installations Only 8 Contents 9 Prepare the Hood 10 12 Prepare the Hood Location 13 EZ1 One Person Installation 13 15 Install the Hood EZ1 Bracket 16 17 Standard Installation 18 Install the Hood Standard Installation 19 Connect the Wiring 20 Install the Filters 20 Wiring Diagram 21 Service Parts 22 23 Wa...

Page 3: ...applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Ref...

Page 4: ...and you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA CAUTION For indoor use only For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors To avoid motor bearing damage and nois...

Page 5: ...ve device that activates the blower when an abnormally high heat level is detected while the blower is activated During the Heat Sentry activation this device takes control of the blower and set it on MEDIUM speed while all dots under the blower icon blink However the lights can be still controlled The blower will remain on MEDIUM speed until the heat is back to normal it then returns to the speed...

Page 6: ...e in the elevated temperatures of cooking offering bright lighting and lasting up to 25 times as long as a standard bulb and greater reliability than typical replacement LED bulbs MASTER ON OFF Press this button to turn on the lights and the blower at the last saved intensity When either lights or blower are ON pressing this button will memorize the current blower speed and lighting level prior to...

Page 7: ...ulation filters FAN WHEELS The center of the fan wheels should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent Always clean in the direction of original polish lines Always rinse well with clear water 2 or 3 times after cleaning Wipe dry compl...

Page 8: ... COOKING SURFACE CABINET 3 X 10 DUCT FOR HORIZONTAL DISCHARGE WALL CAP ROOF CAP 3 X 10 OR 7 ROUND DUCT FOR VERTICAL DISCHARGE HOUSE WIRING TOP OR BACK OF HOOD HOOD NOTE Distances over 30 are at the installer and user discretion 1 Determine whether hood will discharge vertically 3 x 10 or 7 round or horizontally 3 x 10 only 2 Decide where the ductwork will run between the hood and the outdoors 3 Ch...

Page 9: ...de l armoire et plier le gabarit en conséquence To be translated in Spanish FIND EZ1 BRACKETS ATTACHED INSIDE OF HOOD 2 GREASE FILTERS FIND PARTS BAG INSIDE OF HOOD FIND INSIDE ONE PACKAGING STYROFOAM OF HOOD 1 3 X 10 DAMPER ASSEMBLY 1 7 ROUND DUCT CONNECTOR 1 PARTS BAG CONTAINING 6 NO 8 X 5 8 RD HD WOOD SCREWS 2 INSTALLATION BRACKETS FOR FRAMED CABINET 2 INSTALLATION BRACKETS FOR FRAMELESS CABINE...

Page 10: ... models 3 Using the finger cup remove the grease filters from the hood by pushing down and tilting filters out 7 ROUND DUCT PLATE 2 SCREWS 1 2 3 4 5 6 7 4 Using a 11 32 nutdriver or socket remove the lock nut retaining the flange of the right cover plate shaded part on illustration below to the inner back of hood see inset Remove the right cover plate retaining screws 7 screws then set the blower ...

Page 11: ...TRICAL POWER CABLE KNOCKOUT 5 Remove the parts bag taped on the inner back of hood near the left corner Remove the EZ1 brackets from inside the hood by cutting off the tie wrap Discard the tie wrap EZ1 BRACKETS PARTS BAG LOCATION RECIRCULATION COVER PLATE SCREWS NON DUCTED INSTALLATION ONLY 7 Remove 3 screws retaining the recirculation cover plate to the hood Discard this plate with its screws Pee...

Page 12: ...enter ductwork the 7 round duct plate can be installed up to 1 2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 HORIZONTAL KNOCKOUT PLATE FIGURE 1 A 7 ROUND DUCT PLATE SCREWS FIGURE 3 3 X 10 DAMPER ASSEMBLY TOP BACK EDGE OF HOOD DAMPER FLAP PIVOT SCREWS FIGURE 2 A FIGURE 2 B 9 Attach 3 x 10 Damper Assembly o...

Page 13: ...ECTANGULAR DUCTING 7 ROUND DUCTING OR Use this template for marking do not attempt to cut out the ducting hole through it NOTE These cutouts are clearance holes they do not need to be the exact size of ducting 3 po x 10 po 3 po x 14 po CONDUIT RECTANGULAIRE CONDUIT ROND DE 7 PO OU 3 pulg x 10 pulg 3 pulg x 14 pulg CONDUCTO RECTANGULAR CONDUCTO REDONDO DE 7 PULG O Utiliser ce gabarit pour marquer v...

Page 14: ...ews Repeat for the other side frame 7 Install the proper installation brackets according to the type of cabinet framed or frameless See below 4 Drill a 1 8 dia pilot hole for house wiring at B location on template 5 Use a sharp pencil or 1 8 drill bit to mark the locations for the appropriate duct access holes 16 locations for 7 round duct or 4 corner locations for rectangular duct Remove the temp...

Page 15: ...l Draw a line on the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align side edge to marked line keeping the rear end edge leaning on the wall Use a pencil to mark 3 holes Remove the bracket Using a 7 64 drill bit drill 3 holes where marked Assemble the bracket to the cabinet bottom using a Phillips screwdriver and 3 provided countersunk wood screws Repeat...

Page 16: ...ssed REAR HOLES A and B While holding the hood run the house power cable into the hood through the strain relief previously installed in step 6 on page 11 4 Unhook the rear holes from the brackets and hang the hood using its 2 recessed FRONT HOLES C and D While holding the hood go to step 6 5 Hang the hood on the brackets using the 2 recessed FRONT HOLES C and D While holding the hood tighten an a...

Page 17: ... in parts bag Insert two 2 screws per side in the slots as shown in insets on illustration below 8 For frameless cabinet secure the hood to the cabinet using four 4 no 8 x 5 8 round head wood screws included in parts bag Insert two 2 screws in the slots as shown in insets on illustration below 9 Attach power cable to the hood using the strain relief WOOD SCREWS METAL SCREWS ...

Page 18: ...OLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1 1 9 47 16 CABINET BOTTOM REAR HOOD MOUNTING SCREWS 2 12 30 HOOD 15 36 HOOD 18 42 HOOD 12 30 HOOD 15 36 HOOD 18 42 HOOD 3 X 10 VERTICAL DUCTING CABINET BOTTOM CABINET FRONT HORIZONTAL DUCT ACCESS HOLE REAR HOOD MOUNTING SCREWS 2 ELECTRICAL ACCESS HOLE IN WALL 3 CENTER LINE WOOD SHIMS RECESSED BOTTOM CABINETS ONLY 13 ...

Page 19: ...rds wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood Tighten screws securely and maintain a hold on the hood until completing step 3 3 Secure the hood to the cabinet using two 2 no 8 x 5 8 round head wood screws included in parts bag Insert one 1 screw per side in the slots as shown below Attach power cable to the hood using the strain relief 4 Connect duct...

Page 20: ...al wiring must be done by qualified personnel in accordance with all applicable codes and standards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally MOTORS GROUND WIRE HOUSE POWER CABLE GROUND SCREW 1 2 3 4 5 6 7 Install the Filters Ducted Installation Only Re install grease filters removed in step 3...

Page 21: ...R Low O Medium BK High W BK BK W G Y 120 V AC Line Neutral Ground W G Y PP G Y PP W W BK FAN MOTOR FAN MOTOR R O BK G Y W R O BK G Y W BN BN S BK BK BN BN S BK BK 1 2 3 4 5 W 1 2 3 4 5 BK O 120 BL 88 PP 60 PN 45 Y 10 W W COLOR CODE BK BL BN BN S G Y O BLACK BLUE BROWN BROWN STRIPE GREEN YELLOW ORANGE PN PP R W Y PINK PURPLE RED WHITE YELLOW Fuse 5 A 1 2 3 4 5 6 1 2 3 4 5 6 BK W R BK BCDJ AND NCDJ ...

Page 22: ...RMER AND FUSE 1 1 1 S97020360 PARTS BAG INCLUDING 4 METAL SCREWS NO 8 18 X 1 2 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK WOOD SCREWS 1 1 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTALLATION ONLY 1 1 1 S99527587 NON DUCTED FILTER CLIP KIT INCL 4 CLIPS 1 1 1 S97020470 EASY INSTALL KIT INCLUDING HARDWARE 1 1 1 ITEM NOT SHOWN NOT AVAILABLE FOR NCDJ SERIES NOT INCLU...

Page 23: ...20796 WIRE HARNESS WITH AUTOTRANSFORMER AND FUSE 1 1 1 1 1 S97020360 PARTSBAGINCLUDING 4METALSCREWSNO 8 18X1 2 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK WOOD SCREWS 1 1 1 1 1 S97020467 NON DUCTED FILTER TYPE XD SET OF 2 NON DUCTED INSTALLATION ONLY 1 1 1 S97020468 NON DUCTED FILTER TYPE XE SET OF 2 NON DUCTED INSTALLATION ONLY 1 1 S99527587 NON DUCTED FILTER CLIP KIT INCL 4 CLIP...

Page 24: ...t no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by the Company you must properly pack the Product or part the Company is not responsible for damage in transit The Company reserves the right to utili...

Reviews: