INSTALL THE DUCTWORK 
(Ducted Hoods Only)

1. Decide where

the ductwork
will run
between the
hood and the
outside.

2. A straight, short

duct run will
allow the hood
to perform most
efficiently.

3.  Long duct

runs, elbows
and transitions
will reduce the
performance of
the hood. Use as few of them as possible. Larger ducting
may be required for best performance with longer duct runs.

4.  Install wall cap or roof cap. Connect round metal ductwork

to cap and work back towards the hood location. Use duct
tape to seal the joints between ductwork sections.

MEASURE THE INSTALLATION

The minimum hood distance above cooktop MUST NOT BE 
LESS than 30”. 
A maximum of 36” above cooktop is highly recommended for 
best capture of cooking impurities.

 

Distances over 36” are at the installer and users discretion; 
providing that the ceiling height permits. 

PREPARE THE HOOD

6”

ROUND

 

DUCT

ROOF

 

CAP

ROUND

ELBOW

30” 

TO

 36” 

ABOVE

COOKING

 

SURFACE

WALL

 

CAP

HOOD

DECORATIVE

FLUE

HOOD

12 

1

/

2

” 

TO

 

CENTER

OF

 

BRACKET

 

HOLES

ROUND

 

ELBOW

HOOD

 

MOUNTING

BRACKET

30” 

TO

 36” 

ABOVE

COOKING

 

SURFACE

 *

3¼”

DECORATIVE

 

FLUE

 

6” 

ROUND

 

DUCT

ROOF

 

CAP

WALL

 

CAP

Unpack hood and check contents. You should receive:
1 - Hood
1 - Glass Canopy (Models B5630SS & B5636SS)
1 - Metal Canopy (Models B5730SS & B5736SS)
1 - Decorative Flue Assembly
1 - Damper / Duct Connector
1 - Lower Flue Mounting Bracket
1 - Upper Flue Mounting Bracket
1 - Hood Mounting Bracket
2 - Aluminum Grease Filters (installed in hood)
1 - Parts Bag containing:

8 - Mounting Screws (#8 x 3/8” Pan Head)
7 - Mounting Screws (#8 x 1-1/2” Flat Head)
4 - Mounting Screws (M4 x 1.0 Flat Head)
7 - Drywall Anchors
2 - Washers
4 - Decorative Washers

1 - Installation Manual

7 MOUNTING

SCREWS

(#8 X 1-1/2”

Flat Head)

7 DRYWALL

ANCHORS

8 MOUNTING
SCREWS 
(#8 x 3/8”
Pan Head)

DECORATIVE FLUE

2  WASHERS

UPPER

FLUE MOUNTING

BRACKET

HOOD

MOUNTING

BRACKET

LOWER

FLUE MOUNTING

BRACKET

DAMPER / DUCT

CONNECTOR

4 MOUNTING
SCREWS
(M4 X 1.0”
Flat Head)

4 DECORATIVE

WASHERS

Summary of Contents for B5630SS

Page 1: ...uently Grease should not be allowed to accumulate on fan or filters d Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PE...

Page 2: ...mits PREPARE THE HOOD 6 ROUND DUCT ROOF CAP ROUND ELBOW 30 TO 36 ABOVE COOKING SURFACE WALL CAP HOOD DECORATIVE FLUE HOOD 12 1 2 TO CENTER OF BRACKET HOLES ROUND ELBOW HOOD MOUNTING BRACKET 30 TO 36 A...

Page 3: ...Minimum 31 Maximum 36 for both ducted and non ducted discharge NOTE 10 ft ceilings require 10 ft Flue Extension Model FXN56SS for ducted or non ducted installations purchase separately 9 421 2 bottom...

Page 4: ...3 8 Pan Head mounting screws 4 Remove the grease filters by pulling down the metal latch tab and tilting filters downward to remove 5 Carefully rotate hood upright HD0255A HOLES LOCATION 5 16 TYP MOTO...

Page 5: ...overing the upper flue and the hood 16 Mount the glass plate or the stainless steel plate on the top of hood base with 4 flat head screws M4 x 1 0 and 4 decorative washers Screw from top of hood base...

Page 6: ...filter into position and release Make sure filters are securely engaged after installation 14 Slightly push aside the upper flue to avoid any damage while installing the lower flue to the hood top usi...

Page 7: ...the hood mounting bracket Gently lower the hood until it securely engages the bracket 16 With the hood hanging in place drill through both holes located in the inside lower back of hood using a 5 16...

Page 8: ...ormance This discoloration is not covered by the warranty Non Duct Recirculation Filters Change the non duct recirculation filters every 6 months Rotate the filters to remove them from the blower and...

Page 9: ...tal Plate with Rail B5736SS 1 9 S99526983 Damper Duct Connector 1 10 S99526984 6 Dia Expandable Flexible Aluminum Duct 1 11 S99526985 Non Duct Plenum Assembly 1 12 S99526987 Hood Mounting Bracket 1 13...

Reviews: