background image

Page 2

MODEL  741SN 

TYPICAL INSTALLATIONS 
(continued)

SUSPENDED CEILINGS

Housing hung with wires - 3-point mount.

3. Set housing aside and drive nails partially into joist at the 

top of both keyhole marks.

4. Hang housing from nails and pound nails tight. To ensure 

a noise-free mount, pound another nail through the top 

hole of each mounting tab.

INSTALL THE HOUSING 
(continued)

New Construction

Existing Construction

2. In attic, position mounting brackets against joist. Trace 

outline of housing on ceiling material.

1.  Choose the location for your fan/light in the ceiling. For best 

possible performance, use the shortest possible duct run 

and a minimum number of elbows.

3. Set housing aside and cut ceiling opening slightly larger 

than marked.

MOUNTING

TAB

GRILLE

PAN

SUSPENDED

CEILING

MATERIAL

POWER

CABLE

4" ROUND

DUCT

HOUSING

GLASS

LIGHT SHADE

INSTALL THE HOUSING

1. Choose the location for your fan in the ceiling. For best 

possible performance, use the shortest possible duct run 

and a minimum number of elbows.

2. Position mounting brackets against joist so that bottom  

edge of housing will be flush with finished ceiling.

 

Additional positioning feature for 5/8”, 1”, &

 

1-1/4” thick ceiling material:

 

Holes in corners of housing are labeled with various 

ceiling material thicknesses. Position housing so 

bottom edge of joist is visible through a matched 

set of holes. The housing is now in the proper 

position for that ceiling material thickness.

 

Additional positioning feature for 1/2” thick 

ceiling material:

 

Bend two tabs, on side of housing, 90

0

 outward. Lift 

housing until tabs contact underside of joist.

  Mark the keyhole slot on both mounting brackets.

New Construction

5/8

1

1-1/4

TAB

HOLES

BOTTOM EDGE OF JOIST

- PLEASE NOTE -

THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 2 X 

6 JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST INSTALLATION, 

MOUNT THE VENTILATOR TO THE ADDITIONAL FRAMING IN 

THE SAME MANNER. (Additional framing must be a 2x6 (mini-

mum height).

Summary of Contents for 741SN

Page 1: ...ation in ceilings up to a 12 12 pitch Ductwork must point up DO NOT MOUNT THIS PRODUCT IN A WALL 3 The light fixture assembly must be mounted to the fan housing assembly included with this product Do...

Page 2: ...e the location for your fan in the ceiling For best possible performance use the shortest possible duct run and a minimum number of elbows 2 Position mounting brackets against joist so that bottom edg...

Page 3: ...ise free installation drive another nail through the top hole of each mounting bracket Existing Construction 5 Additional mounting holes are provided for installations where access from above is incon...

Page 4: ...llation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do no...

Page 5: ...te producto est dise ado para instalarse en cielos rasos con una pendiente de hasta 12 12 El sistema de conductos debe apuntar hacia arriba NO MONTE ESTE PRODUCTO EN LA PARED 3 Para evitar causar da o...

Page 6: ...IOR DE LA VIGUETA 2 Coloque las abrazaderas de montaje contra la vigueta de ma nera que el borde inferior de la cubierta quede al ras del cielo raso terminado Caracter stica adicional para la colocaci...

Page 7: ...onducto debe quedar al ras de la parte superior de la cubierta NOTA Aseg rese de que la tapa del regulador de tiro est colocada dentro del conector del conducto Si no lo est Comprima la parte superior...

Page 8: ...ndebida excepto por Broan NuTone instalaci n defectuosa o instalaci n contraria a las instrucciones de instalaci n La duraci n de cualquier garant a impl cita se limita a un per odo de un a o seg n se...