background image

MODEL  349BR

Page 1

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 

TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel  and  lock  the  service  disconnecting  means  to  prevent 

power from being switched on accidentally. When the service 

disconnecting  means  cannot  be  locked,  securely  fasten  a 

prominent warning device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-rated construction codes and standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 

to  prevent  backdrafting.  Follow  the  heating  equipment 

manufacturer's guidelines and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and  the  American  Society  for  Heating,  Refrigeration  and 

Air  Conditioning  Engineers  (ASHRAE),  and  the  local  code 

authorities.

5.  When  cutting  or  drilling  into  wall  or  ceiling,  do  not  damage 

electrical wiring and other hidden utilities.

6.  The wiring must be permanent. DO NOT USE AN EXTENSION 

CORD! Use 14 GA. MINIMUM copper wire. Although the Powered 

Attic Ventilator may be wired directly to power, we advise that 

some type of shut off switch be installed in the line. Please see 

the section on electrical wiring for suggested wiring diagrams 

and instructions.

7.  To reduce the risk of electric shock, do not use this fan with 

any solid-state speed control device.

8.  This unit must be grounded.

CAUTION  

1.  For general ventilating use only. Do not use to exhaust hazardous 

or explosive materials and vapors.

2.  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 

unit.

3.  This unit has an unguarded impeller. Do not use in locations 

readily accessible to people or animals.

4.  Fan  is  equipped  with  a  thermostat  which  may  start  fan 

automatically. To reduce risk of injury or electric shock while 

servicing or cleaning unit, switch power off at service panel 

and lock service panel to prevent power from being switched 

on accidentally. When the service disconnecting means cannot 

be locked, securely fasten a prominent warning device, such 

as a tag, to the service panel.

5.  Home Ventilating Institute (HVI) recommends one square foot 

of open air inlet per 300 cfm of fan capacity. The best location 

for these air intake vents are under the eaves with direct access 

to the attic. Failure to provide these intakes could cause natural-

draft gas appliances to backdraft.

6.  Your attic fan installation will create a screened opening into 

your attic space. During a heavy rain storm there could be a 

light spray of rain into this attic space. This is a normal condition 

with all attic ventilators and will not cause any damage to the 

structure. We recommend that you do not store any valuable 

articles directly under the fan opening in the roof. During extreme 

rain and wind storms you may want to turn on your attic ventilator 

to prevent excess moisture accumulation in your attic.

7.  Records show, under ideal conditions, exposed galvanized steel 

can remain rust free up to 100 years. For best protection, the 

exposed portion of the roof sheet should be painted, especially 

in areas of unusually high industrial air pollution. Follow paint 

manufacturer's instructions for good adhesion.

8.  This ventilator is intended for roof installation. The Broan Model 

353 Gable Mount Ventilator is available for side wall applications.

9.  The dome may be painted with a high-quality paint. Follow the 

paint manufacturer's recommendations for powder-coated steel.

10. Please read specification label on product for further information 

and requirements.

ROOF-MOUNT 

POWERED ATTIC VENTILATOR

READ AND SAVE THESE INSTRUCTIONS

Slotted Screwdriver

Drill

1/4" Drill Bit

Sabre Saw or Keyhole Saw

Hammer

Ruler

Pencil

Utility Knife

Pry Bar (to remove roofing nails)

Roofing Cement

Galvanized Roofing Nails (1¾" min.)

Electrical Supplies (to comply with codes)

TOOLS AND MATERIALS REQUIRED