background image

MODELS   345SOBK • 345SOWW

Page 1

WARNING 

 

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 

TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, disable the ventilator by cover-

ing the solar panel with cardboard or disconnecting the wires 

from the motor terminals (note wire locations when disconnect-

ing).

3.  Installation work must be done by a qualified person(s) in ac-

cordance with all applicable codes and standards, including 

fire-rated construction codes and standards.

4.  If removing an existing 120 VAC powered attic ventilator, use 

only a qualified person(s) to remove any electrical wiring in 

accordance with all applicable codes and standards.

5.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 

to prevent backdrafting. Follow the heating equipment manufac-

turer's guidelines and safety standards such as those published 

by the National Fire Protection Association (NFPA), and the 

American Society for Heating, Refrigeration and Air Condition-

ing Engineers (ASHRAE), and the local code authorities.

6.  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

CAUTION  

1.  For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2.  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 

unit.

3.  This unit has an unguarded impeller. Do not use in locations 

readily accessible to people or animals.

4.  This ventilator operates when the solar panel is exposed to 

sun light. To reduce risk of injury while installing, servicing or 

cleaning unit, cover the solar panel with cardboard or discon-

nect the wires from the motor terminals (note wire locations 

when disconnecting).

5.  The recommended open air inlet for this ventilator is 2 square 

feet. The best location for these air intake vents are under the 

eaves with direct access to the attic. Failure to provide these 

intakes could cause natural-draft gas appliances to backdraft.

6.  Your attic fan installation will create a screened opening into 

your attic space. During a heavy rain storm there could be a 

light spray of rain into this attic space. This is a normal condi-

tion with all attic ventilators and will not cause any damage to 

the structure. We recommend that you do not store any valu-

able articles directly under the fan opening in the roof. 

7.  This ventilator is intended for roof installation. Broan Models 

353, 345GOBK & 345GOWW Gable Mount Ventilators are 

available for side wall applications.

8.  The plastic ventilator dome and base may be painted with 

high quality paint. Follow the paint manufacturer's recommen-

dations for acrylic and ABS plastic as appropriate. Take care 

to avoid getting paint on the solar panel.

9.  This ventilator includes a permanently lubricated motor. Do 

not oil or disassemble.

10. The installation instructions contained in this document are 

only a recommendation and individual professionals may 

have their own methods of installation. If your roof has an 

existing warranty, installation of this product by anyone other 

than those who installed the roof may jeopardize any future 

warranty claim. Please check with the original installer of your 

roof if this is a concern. 

11.  When working with asphalt shingles in cold weather (below 

40

o

F), take care to avoid damage to the shingle edges and 

corners.

12. For installations in climates where cold weather condensation 

is not a concern, Broan Model CWT45 thermostat is available. 

It disconnects power to the motor when the temperature drops 

below 50

o

F. Power is applied to the motor when the tempera-

ture reaches 61

o

F.

ROOF-MOUNT 

SOLAR POWERED

 

ATTIC VENTILATOR

READ AND SAVE THESE INSTRUCTIONS

Drill

1/4" Drill Bit

Sabre Saw or Keyhole Saw

Hammer

Ruler / Tape Measure

Pencil, Marker or Scribe

Utility Knife

Pry Bar (to remove roofing nails)

5/16" Socket and Extension

Roofing Cement

Galvanized Roofing Nails (1¾" min.)

TOOLS AND MATERIALS REQUIRED

Register your product online at:

www.broan.com/register

Summary of Contents for 345SOBK

Page 1: ...is 2 square feet The best location for these air intake vents are under the eaves with direct access to the attic Failure to provide these intakes could cause natural draft gas appliances to backdraft...

Page 2: ...dards 1 Determine the sun s best exposure location on your roof barring shade trees other buildings etc at 4 00pm in the hottest month of the year Generally we recommend a point located 24 36 on cente...

Page 3: ...for the sabre saw just inside of the line or the 14 circle created in Step 8 10 Cut out the roof board s inside of the line 11 For proper removal of roofing nails draw a 27 square centered around the...

Page 4: ...ard the roof ridge Start two thirds of the way down from the top of the 27 square and slide the ventilator base under the shingles Do not bend the shingles any more than necessary Center the ventilato...

Page 5: ...1 77001311 77001313 Solar Panel Assembly Dome 2 CWT45 CWT45 Thermostat Optional 3 79310005 79310005 Fan Blade w Set Screw 4 79080082 79080082 Motor DC 5 77001284 77001287 Roof Sheet Panel SERVICE PAR...

Page 6: ...ion herein to the contrary this Warranty shall not extend or obligate Broan to take any action with respect to A Products which have been modified altered installed used or operated in a manner which...

Page 7: ...L entr e d air recommand e pour ce ventilateur est de 0 19 m2 2pi2 Lemeilleuremplacementdecesentr esd airestsousles avant toitacc dantdirectementaugrenier N gligerd am nager de telles entr es d air ri...

Page 8: ...le plus expos au soleil sur le toit et sans ombre arbres autres b timents etc 16 h dans le mois le plus chaud de l ann e En r gle g n rale nous recommandons un point situ environ 61 91 cm 24 36 po au...

Page 9: ...euse juste l int rieur de la ligne du cercle de 35 6 cm 14 po trac l tape 8 10 Coupez le ou les panneaux du toit l int rieur de la ligne 11 Pour enlever correctement les clous toiture tracez un carr d...

Page 10: ...glissez la base du ventilateur sous les bardeaux des deux tiers sup rieurs du carr de 68 6 cm 27 po Ne pliez pas les bardeaux plus que n cessaire Centrez la base du ventilateur sur l ouverture CLOUS...

Page 11: ...Ensemble de panneau solaire d me 2 CWT45 CWT45 Thermostat optionnel 3 79310005 79310005 H lice de ventilateur avec vis d arr t 4 79080082 79080082 Moteur CC 5 77001284 77001287 Panneau de base PI CES...

Page 12: ...ne saurait obliger Broan prendre des dispositions en ce qui a trait A des produits ayant t modifi s alt r s install s utilis s ou ayant servi d une mani re non recommand e par Broan y compris tout pr...

Page 13: ...entrada de aire abierta recomendada para este ventilador es de 2 pies cuadrados 0 19 metros cuadrados La mejor ubicaci n para estas ventilaciones de admisi n de aire es debajo de los aleros con acceso...

Page 14: ...ci n del techo con la mejor exposici n al sol y que no tenga sombra de rboles otros edificios etc a las 4 00 p m en el mes m s c lido del a o Por lo general recomendamos un punto situado de 24 a 36 pu...

Page 15: ...nea o del c rculo de 14 pulg 35 6 cm creado en el paso 8 10 Recorte las tablas del techo dentro de la l nea 11 Para poder quitar adecuadamente los clavos del techo dibuje un cuadrado de 27 pulg 68 6 c...

Page 16: ...la a la saliente del techo inicie en los dos tercios inferiores del cuadrado de 27 pulg 68 6 cm y deslice la base del ventilador debajo de las tejas No doble las tejas m s de lo necesario Centre la ba...

Page 17: ...to del panel solar domo 2 CWT45 CWT45 Termostato opcional 3 79310005 79310005 Aspa del ventilador con tornillo de fijaci n 4 79080082 79080082 Motor CC 5 77001284 77001287 Panel de hoja del techo PIEZ...

Page 18: ...ci n en la presente que se ale otra cosa esta Garant a no se ampliar para Broan ni la obligar a tomar medida alguna con respecto a A Productos que hayan sido modificados alterados instalados usados u...