background image

 

 

Repeat48/Repeat48WDM

 

5 / 21 

rev. 2.1 

 

 

Cleaning 

Only  use  a  dry  linen  cloth  to  clean  the  device.  If  the  unit  is  very  dirty,  moisten  a  cloth  using  a  little 
water and a small amount of household detergent. Never use cleansing agents containing solvents to 
clean the device. 

 

Operating and Storage Temperature 

Operating temperature:  -20

°

50

°

 -4

°

 122

°

F; ensure proper ventilation 

Storage temperature:  -20

°

60

°

 -4

°

 140

°

F  

 

Power Supply 

The  device  can  be  disconnected  from  the  power  supply  by  unplugging  the  power  cord.  The  power 
cords  must  be  freely  accessible  at  all  times.  The  device  should  be  disconnected  during  lightning 
storms or when the device is unused for a long period of time.  

 

 

 

Never disconnect the main plug by pulling the cable. Always unplug the device. 

Power-supply cords should be routed in such a way that they are not likely to be walked on, crushed, 
pinched,  or  damaged  in  any  other  way.  Pay  special  attention  to  the  plugs  and  the  sockets  of  the 
device. 

 

 

 

 

Fuse 

There  is  no  fuse  in  the  device.  The  power  supplies  contain  circuitry  that  protects  the  device  from 
overload.  

 

Lightning 

For  additional  protection  of  this  device  during  lightning  storms,  or  when  it  is  left  unattended  and 
unused for a long period of time, disconnect the power cord. This will prevent damage to the device 
due to lightning and power line surges. Disconnection from the mains power supply is only possible 
by disconnecting the power plug from the mains socket. 

 

Eye Safety 

This  product  is  a  Laser  Class  1  product.  It  complies  with  IEC  60825-1,  FDA  21  CFR  1040.10,  and 
1040.11. 

Important:

 

The switched-mode power supplies operate at very high voltages.  

Coming  into  contact  with  the  power  supplies  can  lead  to  considerable  electric 
shock, which may result in death. 

Important:

 

A damaged power cable must be replaced immediately. 

The  device  must  be  grounded.  Disconnecting  the  ground  is  strictly  prohibited. 
Ensure that the device is always grounded using the power connector.  
Do  not  cover  the  ground  connection  of  the  power  connector  with  any  kind  of 
insulation material! 

Summary of Contents for Repeat48 Series

Page 1: ... Repeat48 Repeat48WDM Operating Manual Rev 2 1 Operating Manual for Repeat48 Repeat48WDM Digital Video Network device Copyright 2017 All rights reserved BROAMAN GmbH Lohenstr 8 82166 Munich Gräfelfing Germany ...

Page 2: ...Page intentionally left blank ...

Page 3: ... Protect the power cord from being stepped on crushed pinched or damaged in any other way Pay special attention to plugs and sockets of the device Do not place this device on an unstable table tripod cart etc The device may fall causing serious damage to the device The device can be disconnected from the power supply by pulling the plug These must be freely accessible at all times The device shoul...

Page 4: ...and audio visual and entertainment lighting control apparatus for professional use E1 Residental E2 Commercial and light industrial E3 Urban outdoors E4 Controlled EMC environment e g broadcast and TV studio E5 Heavy industry The product is intended for the use in moderate climate Ventilation Do not block or cover any ventilation openings Install the device in accordance to the operating manual Al...

Page 5: ... the plugs and the sockets of the device Fuse There is no fuse in the device The power supplies contain circuitry that protects the device from overload Lightning For additional protection of this device during lightning storms or when it is left unattended and unused for a long period of time disconnect the power cord This will prevent damage to the device due to lightning and power line surges D...

Page 6: ...al fibre cables are covered with the provided caps Do not place this device on an unstable table tripod cart etc The device may fall which can cause injury and serious damage to the device Any mounting of the device should follow the manufacturer s instructions and should use mounting accessories recommended by the manufacturer of the device Servicing Do not attempt to service the device by yourse...

Page 7: ...ection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case you wi...

Page 8: ...Page intentionally left blank ...

Page 9: ...NC Ports 13 Fibre Ports 13 Multiplexers 13 Power Supply 13 Control 13 Connectors and Cables 14 3G HD SD SDI and MADI Ports 14 Optical Connections 14 Power Connection 14 Ordering Options 15 Repeat48 12 15 Repeat48 24 15 Repeat48WDM 12 16 Repeat48WDM 24 16 Connection Example 17 Technical Specifications 18 Dimensions and Weight 18 Warranty and Liability 19 Summary of Warranty 19 How to Obtain Warrant...

Page 10: ...modular nature of DiViNe paves the way for construction of fully cost optimized systems Repeat48 Reepeat48WDM is an application engineered electrical optical electrical converter for 3G HD SD SDI or AES10 MADI signals converting between coaxial and optical connections Repeat48 Reepeat48WDM can be populated with up to 12 dual channel 3G HD SD SDI or AES10 MADI modules and SFP fibre optic transceive...

Page 11: ...8 and Repeat48WDM Input status LED Signal indicator for channels 1 24 LED ON Signal is present LED OFF No signal is present PWR 1 LED Green Power supply 1 is operational and receiving power PWR 2 LED Green Power supply 2 is operational and receiving power ...

Page 12: ...nternal WDM CWDM or DWDM modules Coaxial ports 1 24 Populated with up to 12 Dual channel electrical optical electrical 3G HD SD SDI or AES10 MADI modules Each port can be configured by the manufacturer as Input Output The coaxial ports are connected internally to SFP fibre transceivers that feed the specified WDM CWDM or DWDM multiplexers POWER 1 and 2 AC input for power supply 1 and 2 100 240 V O...

Page 13: ...8WDM can optionally be populated with passive WDM CWDM or DWDM multiplexing module s as required by the application Power Supply The device is optionally equipped with two power supplies and inputs If the primary power supply were to fail due to disruption of the power source or in the case of a power supply malfunction the device will automatically switch over to the redundant power supply In ord...

Page 14: ...9 µm fibre cable can be used for applications requiring cable lengths of up to 80 km dependent on bandwith and the quality of the optical cables AES10 MADI Multichannel Audio Multi mode AES10 MADI transceivers connected using a 62 5 µm OM1 fibre cable or better can be used for applications requiring cable lengths of up to 2000 m worst case Single mode AES10 MADI transceivers connected using a 9 µm...

Page 15: ...OUT 12 x fiber IN 2 x PSU Repeat48 24 Code Description R4824002P Repeat48 24 24 x 3G SDI IN 24 x fiber OUT 2 x PSU R4822022P Repeat48 24 22 x 3G SDI IN 2 x 3G SDI OUT 2 x fiber IN 22 x fiber OUT 2 x PSU R4820042P Repeat48 24 20 x 3G SDI IN 4 x 3G SDI OUT 4 x fiber IN 20 x fiber OUT 2 x PSU R4818062P Repeat48 24 18 x 3G SDI IN 6 x 3G SDI OUT 6 x fiber IN 18 x fiber OUT 2 x PSU R4816082P Repeat48 24...

Page 16: ...x COM 2 x PSU R48W20042PA4 Repeat48WDM 24 20 x 3G SDI IN 4 x 3G SDI OUT 2 x 1310nm AUX 2 x Optocore Tunnel 2 x COM 2 x PSU R48W18062PA4 Repeat48WDM 24 18 x 3G SDI IN 6 x 3G SDI OUT 2 x 1310nm AUX 2 x Optocore Tunnel 2 x COM 2 x PSU R48W16082PA4 Repeat48WDM 24 16 x 3G SDI IN 8 x 3G SDI OUT 2 x 1310nm AUX 2 x Optocore Tunnel 2 x COM 2 x PSU R48W14102PA4 Repeat48WDM 24 14 x 3G SDI IN 10 x 3G SDI OUT ...

Page 17: ...modules 12 channels and 6 dual 3G SDI output modules The top device is configured with 6 dual 3G SDI input modules and the bottom device is configured with 6 dual 3G SDI output Each device is connected with six dual core single mode fibre cables to the central unit Fig 1 Connections between a Repeat48 12 12 to a Repeat48 12 0 and a Repeat48 0 12 Fig 2 Connections between a Repeat48WDM 8 8 to a Rep...

Page 18: ...ing on the configuration of the device 32VA Max Security classification Class 1 basic insulation connected to the protective grounding conductor Security regulations Harmonised European standard EN60065 Mains connector acc to IEC 950 Cooling Passive via surface and ventilation openings on both sides of the device Dimensions and Weight Dimensions Front panel width 483 mm 19 inch height 44 mm 1 73 i...

Page 19: ...When discovering a problem with an BROAMAN device you should contact either Broaman directly or a dealer distributor to determine and confirm a hardware fault If it is a software issue the hardware must not be returned to BROAMAN BROAMAN will issue a support ticket in this case If hardware service is required within the warranty period take the equipment along with warranty card to the nearest aut...

Page 20: ...ational electric cables which have been supplied on your request and your purchase order cannot be listed above Please note that due to the Ecology reason standard shipment does not contain printed copy of User Manual All latest BROAMAN user manuals can be downloaded from the website http www broadcastmanufactur com index php support downloads Printed version of User Manual is available on a speci...

Page 21: ...1 21 rev 2 1 Contact Information Mailing Address BROAMAN GmbH Lohenstr 8 D 82166 Munich Gräfelfing Germany Telephone 49 0 89 89996460 Facsimile 49 0 89 89996455 Internet www BroaMan com Email inquiry broadcastmanufactur com ...

Reviews: