Unicorn series QIG 

 

Replace bracket B and C step (For cabinet depth is 504 ~ 614 mm): 

1. Remove seven rear screws. 
 
 
 
 
 
 
 
2. Take two original brackets out. 
 
 
 
 
 
 
 
 
 
3. Input bracket B to rear of the rail. 
 
 
 
 
 
 
 
4. Install four screws (don’t tight-up) to combine rail, bracket B and bracket C. 
 
 
 
 
 
 
5. Repeat step 1 ~ 4 for the other side. 
6. Repeat step 3 ~ 10 of install console to finish installation. 
 

original bracket 

original bracket 

bracket B 

bracket B 

bracket C 

Summary of Contents for Unicorn 15

Page 1: ...Unicorn 15 17 19 Console with Modular KVM Switch Quick Installation Guide Rev 1 0 ...

Page 2: ... distance means front bracket to rear bracket cabinet contact your dealer if you need more longer rear brackets 4 If your cabinet depth is 828 1000 mm please refer Replace bracket A step And If your cabinet depth is 504 614 mm please refer Replace bracket B and bracket C step Hardware kits contents 1 Rail with front and rear bracket x 2 Please identify the brackets Right and left sides are differe...

Page 3: ...binet depth 504 614 mm Please refer page 6 5 Screw length 6 mm x 6 6 Screw x 8 7 Key x 2 Install console step 1 Adjust rail until two screws appear 2 Loose Not remove seven rear screws two screws rail Unicorn 15 17 bracket C Unicorn 19 bracket C ...

Page 4: ...djust rail to fit your cabinet 4 Install front and rear bracket on cabinet 5 Tight seven rear screws up 6 Repeat step 1 5 for the other side 7 Push console into rails Be careful rear box loose when take out console from carton ...

Page 5: ... Unlock and pull rail lock switch left and right at the same time then push console to the end 9 Install three screws length 6 mm in rear of the console Both sides 10 Finish installation as below rail lock switch unlock lock ...

Page 6: ...screws 3 Take rear bracket out 4 Adjust rail and input bracket A to rear of the rail then adjust bracket A to fit your cabinet Install 2 3 screws don t tight up upon the length you need One is forbidden 5 Repeat step 1 4 for the other side 6 Repeat step 3 10 of install console to finish installation original bracket bracket A ...

Page 7: ... 2 Take two original brackets out 3 Input bracket B to rear of the rail 4 Install four screws don t tight up to combine rail bracket B and bracket C 5 Repeat step 1 4 for the other side 6 Repeat step 3 10 of install console to finish installation original bracket original bracket bracket B bracket B bracket C ...

Page 8: ...Unicorn 15 17 19 Console with Modular KVM Switch Quick Installation Guide ...

Reviews: