CVPM02, CVPM05, CVFM04 User Guide
CVPM02, CVPM05 Power Modules | CVFM04 Cache Module
Connecting the Remote CVPM05 Module to the MegaRAID Controller
Follow these steps to connect the remote CVPM05 module by cable to the MegaRAID controller.
1. Ground yourself, and make sure that the system is grounded.
2. Remove the cable included in the MegaRAID controller box.
3. Insert one 9-pin cable connector on the cable into the 9-pin J14 connector on the MegaRAID controller, as shown in
the following figure.
Figure 8: Connect the Remote CVPM05 Module by Cable to the MegaRAID 9460-16i Controller
4. Insert the other 9-pin cable connector into the 9-pin connector on the remote CVPM05 module.
Align the cable connectors to make sure they are connected correctly.
Mount without the Remote Mount Board
If you mount the Broadcom retention clip directly to the chassis, make sure that no ground path to the retention clip exists.
If you must attach the retention clip to chassis ground, do not damage the supercapacitor’s outer sleeve when inserting it
into the clip. Damaging the supercapacitor’s outer sleeve and allowing the clip to make contact with the supercapacitor’s
metal case can cause a failure if the retention clip is attached to chassis ground.