AFBR-39xxyyRZ
Application Note

Application Note

Baking

When the device is inserted and soldered to a PCB up to 1 week 
after it has been taken out of the Moisture Barrier Bag, then the 
moisture level in the mold material is low enough to ensure 
minimum mechanical stress while soldering. 

If the device is kept on the production floor for more than 
1 week as described in the last paragraph, it is advised to bake 
the module before soldering. 

Baking is done by removing the devices from the tube and 
placing them in a shallow container so that the package bodies 
do not touch each other. Then, the devices are placed in the 
bake oven, heating the devices to 100°C for 24 hours. After this 
procedure, the moisture content of the devices is low and the 
moisture-induced stress during soldering is reduced. As a 
general guideline, baking is recommended before every 
soldering attempt.

The baking procedure can be done as often as necessary.

Electrostatic Discharge (ESD) Protection

The devices are sensitive to electrostatic discharges and 
therefore must be handled with care in an ESD protected area, 
indicated with the sign shown in 

Figure 4

.

Figure 4  Warning Sign for ESD Protected Area

An ESD event may damage or degrade the device 
performance. The standard DIN 61340-5-1 has to be 
considered. The following ESD preventions should be applied. 
Any smaller ESD prevention program might be unsuitable to 
prevent ESD damages.

ESD floors

ESD tables, ESD work surfaces and ESD storage facilities 
(e.g., trolleys and carts)

ESD wrist straps/connectors for wrist straps

ESD footwear and garments (cotton or special released 
materials)

ESD gloves or finger cots

ESD chairs

ESD tools (e.g., nippers)

ESD preventions at equipment parts (Equipment parts 
which may directly contact the device leads must be made 
of dissipative materials, wherever possible. If dissipative 
materials cannot be used for technical reasons metals 
must be used whose natural non-conductive surface layer 
is sufficiently thin (breakdown voltage <10V). Conducting 
machine parts which may contact the device leads directly 
must be connected to ground without a series resistor. 

ESD packing materials.

ESD Classification

The devices passed the following ESD test: Electrostatic 
Discharge to the Electrical Pins Human Body Model (HBM) with 
U = ±2000V according MIL-STD-883 Method 3015.

Device Mounting

The devices are designed for through-hole mounting on a PCB. 
The minimum distance from the package to the PCB is 
mechanically defined by the design of the housing which is 
given as drawing in the product data sheet

Solderability/Soldering Process

The qualification test, 

Resistance to soldering heat - Standard 

soldering technique (RSH-ST)

, was done with a solder 

temperature of 260°C for 10 seconds (distance to package: 
3 mm) according to JEDEC standard JESD22-B106D.

Hand Soldering/ Rework

Hand soldering or rework is not allowed during production 
process.

If hand soldering is necessary, the following guidelines must be 
observed: 

Heat the devices to 100°C for 24 hours.

Soldering time must be below 350°C and limited to less 
than 3 seconds. 

Do not allow the lead temperature measured on the lead 
close to the mold package to exceed 350°C.

Note: Hand soldering and rework is a badly reproducible 
process. Hand soldering may cause stresses in the mold 
package, which affects optical performance and/or reliability if 
the above guidelines are not observed.

ATTENTION

ESD PROTECTED AREA

OBSERVE PRECAUTIONS

FOR HANDLING

ELECTROSTATIC

DISCHANGE

SENSITIVE

DEVICES

Reviews: