SS 8x1 II Installation and Operation Manual

DESCRIPTION

PRODUCT DESCRIPTION

The SS 8.1 II passively switches or routes a variety of electrical signals to a desti-
nation.  The SS 8.1 II selects any one of 8 stereo inputs to a single stereo output.  The
SS 8.1 II provides PASSIVE switching through gold contact relays. The passive
switching means that the unit can route a signal in either direction.  Due to the pas-
sive nature of the switching, any input level and impedance can be used.  Inputs may
be balanced or unbalanced, while output levels, impedance, distortion, noise and
balancing will match that of the selected input.  In addition to their normal use with
audio signals, the unit can also be used to switch AES/EBU digital signals and tele-
phone lines.

FEATURES

• Operational control by front panel switches with LED indicators, contact closures,

5-volt TTL/CMOS logic levels and/or the multi-drop RS-232 serial port.

• Removable screw terminals (Euro) are provided for audio and remote control con-

nections.

• Audio switching via sealed relays utilizing 2-form-C bifurcated - crossbar silver

alloy with gold overlay contacts.

• Logic functions via microprocessor and non-volatile memory.
• The power-up feature allows the user to select which one source is active at power

up, including the last source selected.

• The “ACT” circuit performs as an audio activity monitor with front panel LED and

open collector status output.

• The “ENABLE” switch provides a safety lock to the front panel source selection

switches.

• The audio “MUTE” switch allows the user to turn off the audio output when acti-

vated.

• The “STEP” function allows the user to single step through each channel or to

automatically sequence with user programmed channel steps and speed.  

• Eight remote inputs, user configured for remote control or “PIP” (GPI) functions. 
• Eight open collector outputs provide remote channel status or may be user pro-

grammed for GPO’s.

• Configuration via dipswitches, serial port menu or burst mode.
• Source number one is configured to route audio to the output in the case of loss of

power to the unit.

• Non-selected sources are terminated with 10K 

Ω

, load resistors.

• The SS 8.1 II may be set on a desktop, mounted on a wall or as part of the new

RA-1, “Rack-Able” mounting shelf.

• Optional RA-1 rack shelf for mounting up to two units in 1-RU.

APPLICATIONS 

Automation source switching; Studio selection and routing; Audio processing selec-
tion; Exciter input selection; Remote broadcast input selection; STL source selec-
tion; Multiple station program on-hold and/or PA switching; EAS audio switching;
ISDN or Phone hybrid feed selection; IFB selection; Satellite audio channel switch-
ing and console monitor inputs and outputs selection.

Summary of Contents for SS 8.1 II

Page 1: ...this information or new editions may be issued to incorporate such changes Broadcast Tools is a registered trademark of Broadcast Tools Inc Copyright 1989 2013 by Broadcast Tools Inc All rights reser...

Page 2: ...nual Table of Contents Section Title Page Introduction 3 Safety Information 3 Who to Contact for Help 3 Product Description 4 Features 4 Applications 4 Front Panel Description 5 Rear Panel Description...

Page 3: ...a hazardous condition WHO TO CONTACT FOR HELP If you have any questions regarding your product or you need assistance please con tact your distributor from whom you purchased this equipment If you wo...

Page 4: ...s the user to select which one source is active at power up including the last source selected The ACT circuit performs as an audio activity monitor with front panel LED and open collector status outp...

Page 5: ...11 modular jack is provided for the multi drop serial port Power Connect the 2 1mm coaxial type power connector into the unit and the power sup ply into a 120 Vac 50 60 Hz power source The front pane...

Page 6: ...al for this product may be down loaded from the Broadcast Tools web site STEP 2 SOURCE TERMINATION RESISTOR REMOVAL Input sources that are not selected are terminated with a 10K If you do not want thi...

Page 7: ...er Up SW11 5 User selected ON Last source selected OFF NOTE Input selection at power up may be configured by holding down the desired channels push button until the mute and Pwr Ser LED s flash Factor...

Page 8: ...llectors The open collectors may be used to provide status to a remote control point to indicate which source is selected The status output for the selected output will go low user programmable functi...

Page 9: ...power up uCDEF Reset to factory defaults uCIIttt Set PIP minimum pulse length ttt 000 255 off to 2 55 seconds CLx Lock front panel x L Lock x U Unlock uCOx Open Collector Control P Pulse Follow F Ful...

Page 10: ...SS 8 1 II v 1 8 Setup Menu 1 Set PIP Minimum 0 2 55 sec Now 1 00 2 Set Remote Mode Open Collector Mode Now Follow 3 Set First Step Channel 0 to disable Now 1 4 Set Last Step Channel 0 to disable Now...

Page 11: ...Receive only 2400 9600 19200 38400 8 N 1 Status Front Panel Indicator LED Remote ACT LED Trip level set at 40db Remote Open collector outputs 12 vdc limit current to 50ma per output Pull ups may be r...

Page 12: ...O OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMP...

Page 13: ...equired to take any measures required to correct interference CANADA WARNING This digital apparatus does not exceed the Class B limits for radio noise emissions set out in the Radio Interference Regul...

Reviews: