8
SS 16.4 Installation and Operation Manual
CONTROLS
DIP (SW-24) Switch Functions
Switch Default
Number Setting
Function
1
OFF
Add 1 to Address (base address is 0)
2
OFF
Add 2 to Address (base address is 0)
3
OFF
Baud Rate: 00 - 9600, 01 - 2400, 10 - 19200, 11 - 38400
4
OFF
Baud Rate: 00 - 9600, 01 - 2400, 10 - 19200, 11 – 38400
5
OFF
Switching Mode
6
OFF
Switching Mode
7
OFF
Power up mode (Off = User programmable)
8
OFF
Remote Control Mode (ON = Enables PIP)
Address (ID) DIP Switches
SW24 – 1
SW24 – 2
ID
OFF
OFF
ID = 0
ON
OFF
ID = 1
OFF
ON
ID = 2
ON
ON
ID = 3
Baud Rate DIP Switches
SW24 - 3
SW24 – 4
Baud Rate
OFF
OFF
9600
ON
OFF
2400
OFF
ON
19200
ON
ON
38400
Audio Switching Mode DIP Switches
SW24 - 5
SW24 – 6
Mode
OFF
OFF
Overlap
ON
OFF
Interlock
OFF
ON
Interlock
ON
ON
Mix
Power up/Last source DIP Switch
SW24 – 7
Function
OFF
User Programmable
ON
Last Source(s) selected
PIP/Remote Mode DIP Switch
SW24 - 8
Function
OFF
Remote Control
ON
PIP enabled
Front Panel Switches
Switch(es)
Function
1-16
Channel Inputs
Output 1,2,3,4
Output selector
MUTE
Mutes selected channel
MACRO
Selects up to 16 Macro’s
Hidden “PGM”
Special programming functions