INSTALLATION
Continued
e-mail:
voice:
360.854.9559
fax:
866.783.1742
9
SS 16.2 Installation and Operation Manual
INSTALLATION
NOTE:
When the ID is set to
0 and the switcher is
configured for PIP,
any time a PIP input
changes, PIP status is
transmitted.
WEBSITE:
Visit our web site for
product updates and
additional information
NOTE:
When the ID is set to 0
and the switcher is con-
figured for PIP, any
time a front panel
switch is pressed, audio
status is transmitted.
Any ID other than 0
requires the unit to be
polled.
Audio Switch Control Commands
*uiio
- Apply input “ii” to output “o”
*uiiA
- Apply input “ii” to both outputs
*uiiMA
- Mute input “ii” for all outputs
*uMo
- Mute output “o”
*uMA
- Mute all outputs
Serial string example:
*1162
Address for unit 1, with input sixteen routed
to output two.
Output Collector Commands
*uORrrL
- Latch open collector “rr”
*uORrrF
- Unlatch open collector “rr”
*uORrrP
- Pulse open collector “rr”
Miscellaneous Retrieval Commands
*POLL
- Respond with unit (ID) address in appropriate time slot.
If there are multiple units on the line, each will respond
with a different delay after receipt of this command.
*uB1
- Turn on burst mode responses. A valid command will
result in response of “RRR”. Error will result in response
of “EEE”.
*uB0
- Turn off burst mode responses (default)
*uSL
- Send Audio Status:
SuLo,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x<CR><LF>. “u” is unit ID,
“o” is output, and “x” is “1” for connected; “0” for not connected
for each respective input.
Thus “S1L2 ,1,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0<CR><LF> says that unit
1, output 2 is connected to input 1.
*uSPii
- Send
(PIP)
status of programmable pulse stretcher input “ii”.
Response is “
SuP,ii,x”
where “x” is 1 if the corresponding input
is high, 0 otherwise.
*uSPA
- Send
(PIP
) status of all programmable pulse stretcher inputs.
Response is “
SuP,A,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x<CR><LF
> where
input 0 is first and input 15 is last. “x” is 1 if the corresponding
input is high, 0 otherwise.
*uSR
- Send status of all open collectors. Response is:
SuA,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x <CR><LF>
*uU
- Send Unit Information:<name(16.2)><version(1.08)>< cr><lf