9

SRC-4 Installation and Operation Manual

INSTALLATION

Outputs 1-4

represent the string data that will be sent over the serial port when

inputs 1-4 are activated. Each output channel can have a custom ON and OFF string.
Special characters may be entered as ASCII HEX characters, to do so enter a “/” fol-
lowed by the hex value.  For example, if you want to send 12345(CR/LF) enter as
the string: 12345/0D/0A and hit the ENTER key to terminate. Each string may be up
to 14 characters long.

To enter strings for an output channel first type the channel number (1-4) followed
by the desired ON string, press enter to complete the string, then type the desired
OFF string, press enter to complete the string. The settings will be saved and you
may enter strings for another channel.

Inputs 1-4 

represent the strings that control relays 1-4. Each input channel can be con-

figured for custom ON and OFF (latching) strings or for a custom ON (pulse) string.

To enter strings for an input channel first type the channel number (5-8) followed by
0 for Pulse mode or 1 for Latch mode, then enter the desired string(s) and press enter
to complete each string. The settings will then be saved and you may enter strings
for another channel. Each string may be up to 14 characters long.

Once you have finished programming the SRC-4 you can power the unit down,
switch it to the Data operation mode and begin using it.

WEBSITE:

Visit our web site for
product updates and
additional information.

Summary of Contents for SRC-4

Page 1: ...nc All Sentinel labeled products are registered trademarks of Broadcast Tools Inc Copyright 1989 2013 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distribut...

Page 2: ...Surge Protection 5 UPS standby power system 5 LED Indicators 5 Power 5 Status Logic Inputs 5 Relay Outputs 6 Operation Configuration Dip switch Setup 7 RS 232 Serial Connection 8 Computer Operation Mo...

Page 3: ...his device If you are unfamiliar with this type of equipment please contact a prop erly qualified engineer to handle the installation and setup of the SRC 4 Broadcast Tools Inc is unable to support NO...

Page 4: ...movable euro block screw terminal con nectors to simplify wiring and service mating plugs are supplied Fully RFI proofed Surge protected internal power supply universal switching power adapter with do...

Page 5: ...channels number 1 thru 4 terminals A closure between an input s A and B terminals will cause the input to go HIGH turn on The four yellow LEDs on the front panel indicate which inputs are active Each...

Page 6: ...w TB2 Bottom Row TB2 RS 232 Serial Connection Connect one end of the reverse modular cable to the RJ11 jack on the rear panel of the product and the other end to the RJ11 to the jack on the S9 9 pin f...

Page 7: ...ial device to send an uppercase U Power up the SRC 4 from power up there is a 3 second window in which a received U will set the SRC 4 s baud rate Once the baud rate is detected and set the SRC 4 will...

Page 8: ...pair mode as soon as a communication failure is detected all relays will be turned off As soon as communications is restored the relays will be set according to the other unit s inputs Data Operation...

Page 9: ...s enter to complete the string then type the desired OFF string press enter to complete the string The settings will be saved and you may enter strings for another channel Inputs 1 4 represent the str...

Page 10: ...t Connectors Inputs Relays Plug in euroblock screw terminals Serial RJ11 with modular cable and S 9 female DB 9 adapter Power Requirement 9 Volt DC 660 ma universal wall transformer supplied Internal...

Page 11: ...HER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED...

Page 12: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 12 APPENDIX...

Page 13: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 13 APPENDIX...

Page 14: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 14 APPENDIX...

Reviews: