SRC-16 Installation and Operation Manual

INSTALLATION

Serial Burst Mode Commands

The burst mode allows a computer or ASCII terminal to control and interrogate

the unit.  This section defines all burst mode commands.  Each burst mode command
starts with an asterisk (*).  Next is a single decimal digit that corresponds to the unit
(ID) address 03.  Following are one or more ASCII characters specifying the 
command.  A carriagereturn is required to terminate each command.  If  the 
command requested a response, the response will consist of an upper case S, 
followed by the unit address, and then the specific response.  If acknowledgments
are enabled, successful commands are responded to with RRR while errors get an
EEE response.  The syntax of each command is given below.  The syntax shows the
command exactly as it should be sent, except that lower case characters represent
values that should be substituted: 

Glossary of Command Notation

Character String

Meaning

Allowable Values

u

Unit ID

03

ii

Input Number

0116

oo   

Relay Number

0116

Setup Commands

*uCCx    Set Serial Speed. x = 0: 2400 1: 9600 2: 4800 3: 38400 

*uCEx    Enable Error and Good Responses   Where x = Y to enable and N = disable. 
In this mode, when a command is sent, the unit will reply (possibly before receiving
the entire command) with “EEE.” If the command is sent correctly, the unit will
reply with “RRR.”

Relay Control Commands

*uORrrL  Latch Relay rr, relay number
*uORrrF  Unlatch Relay rr, relay number
*uORrrPtt  Pulse Relay rr, relay number 01à16.  
Pulse Length tt: 0099 corresponds to 00  9.9 Seconds.

Information Retrieval Commands

*POLL  Respond with unit (ID) address in appropriate time slot.  If there are multi-

ple units on the line, each will respond with a different delay after receipt of
this command.

*uSPii  Send status of input ii. Response is SuP,ii,x where x is 1 if the corresponding

input is high, 0 otherwise.

*uSPA  Send status of all inputs. Response is SuP,A,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x

<CR><LF > where input 1 is first and input 16 is last. x is 1 if the corre-
sponding input is high, 0 otherwise.

*uSR  Send status of all OUTPUTS.  Response is:

SuA,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x,x <CR><LF>

*uU – Send Unit Information :<name(SRC-16)><version n.nn><cr><lf>

WEBSITE:

Visit our web site for
product updates and
additional information.

Summary of Contents for SRC-16

Page 1: ...nt Revisions of this information or new editions may be issued to incorporate such changes Broadcast Tools is a registered trademark of Broadcast Tools Inc Copyright 1989 2007 by Broadcast Tools Inc A...

Page 2: ...Title Page Introduction 3 Safety Information 3 Who to Contact for Help 3 Product Description 4 Inspection 4 Front Panel Description 4 Installation Guidelines 5 Specifications 11 Warranty 12 Jumper co...

Page 3: ...ur hardware software instruction manuals or contact the man ufacturers technical support department WHO TO CONTACT FOR HELP If you have any questions regarding your product or you need assistance plea...

Page 4: ...8400 The SRC 16 may be expand ed to 64 inputs x 64 outputs from a single serial port Optional external Ethernet and USB capabilities may be added The SRC 16 is supplied with LED indicators to display...

Page 5: ...232 serial con nection is made to the male DB 9 connector JP17 18 19 20 are used to reverse the RS 232 transmit and receive pins on the DB 9 Factory setting is the NN position Pin 5 Ground Pin 2 Tran...

Page 6: ...bytes being the lower outputs 8 7 6 5 followed by 4 3 2 1 then the next two bytes representing the upper outputs 16 15 14 13 and 12 11 10 9 If outputs 1 8 15 10 were ON these 4 bytes would appear as 8...

Page 7: ...changes state If a unit does not receive an update from its corresponding paired unit for a period of about 20 seconds it will begin flashing the red RX LED one second on one second off When communica...

Page 8: ...t Number 0116 oo Relay Number 0116 Setup Commands uCCx Set Serial Speed x 0 2400 1 9600 2 4800 3 38400 uCEx Enable Error and Good Responses Where x Y to enable and N disable In this mode when a comman...

Page 9: ...responses 47h 2A 02 47 73 Disable error good responses 48h n 2A 03 48 01 76 Latch output n 00 0F 49h n 2A 03 49 01 77 Unlatch output n 00 0F 4Ah n t 2A 04 41 01 0A 83 Pulse output n 00 0F t time 1 63h...

Page 10: ...000010b 42h Board ID 2 010b Byte count 2 00010b 01001101b 4Dh All Output Status Request 10111001b B9h Check sum 2Ah 42h 4Dh B9h Response string from SRC 16 00101010b 2Ah Start byte 01000100b 44h Board...

Page 11: ...isplay LED s for inputs relays Tx Rx serial data and power Interfacing Inputs Plug in euroblock screw terminals Relays Plug in euroblock screw terminals RS 232 Serial Port Female DB 9 Data flow progra...

Page 12: ...THER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIE...

Page 13: ...oadcast Tools Inc All Rights Reserved Broadcast Tools SRC 16 Serial Remote Control Jumper and Connectors Layout Appendix Modification Date 02 28 07 Relay Set Up Relay Set Up RS 422 482 Set Up Inputs 1...

Page 14: ...ically Isolated Input Configuration Wet Dry Default RS 422 Receive RS 422 Transmit N C Contact Configuration 131 State Street Sedro Woolley WA 98284 360 854 9559 Fax 360 854 9479 Visit us online at ww...

Reviews: