INSTALLATION

Installation Guidelines

Inspection

Please examine your Silence Sentinel

®

Standard for any damage that may have been

sustained during shipping. If any is noted, please notify the shipper immediately and
retain the packaging for inspection by the shipper. The package should contain the
Silence Sentinel

®

Standard and +/- 15 volt DC @ 400 ma wall universal switching

(PS-1515) power supply with domestic power plug.  Manuals may be downloaded
from our web site.

Mounting

Mount the Silence Sentinel

®

Standard where it will be visible and rear panel acces-

sible. The Silence Sentinel

®

Standard may be set on a desktop, mounted on a wall or

optional RA-1 rack shelf for mounting up to three units using supplied hardware.

Surge Protection

The Silence Sentinel® Standard has built-in resistance to voltage changes; we rec-
ommend that you use a power surge protector or line conditioner on the incoming AC
line. Lightning strikes and/or other high voltage surges may damage your Silence
Sentinel® Standard and connected equipment if it is not properly protected.  For
lightning protection devices, check out www.polyphaser.com and www.itwlinx.com.  

UPS Standby Power System

We recommend that you connect your Silence Sentinel® Standard to a UPS system.
A UPS helps minimize the risk to the Silence Sentinel® Standard and provides
power during a power outage. 

POWER:  +/- 15 VDC power connector

Connect the 3-pin AMP-style latching power connector to the unit and the +/-15
VDC switching power supply with domestic connector into a 120 Vac 50-60 Hz
power source.  Never use any type of power supply other than the specified/supplied
(PS-1515) power supply.

Cable Preparation

The Silence Sentinel® Standard interfaces to external equipment through removable
euroblock screw terminals. The terminals accommodate wire sizes from 16 - 28
AWG solid or stranded wire.  Before installing a wire, remove the euroblock screw
terminal plug and turn each capture screw fully counterclockwise. Strip each con-
ductor to a length of 0.25” and insert the conductor fully into the terminal. Turn the
capture screw fully clockwise to secure the conductor. Verify that no bare wires are
exposed.

CAUTION!

Installation of the
Silence Sentinel®
Standard in high RF
environments should be
performed with care.
The station ground
should be connected to
the designated “Chs
Gnd” ground terminal.

WEBSITE:

Visit our web site for
product updates and
additional information.

Summary of Contents for Silence Sentinel Standard

Page 1: ...led products are registered trademarks of Broadcast Tools Inc Copyright 1989 2017 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed without permissio...

Page 2: ...paration 5 Connecting your equipment 5 Relay and Open Collector connections 6 Remote Control connections 7 Programming Guidelines 8 Dipswitch setup 8 Delay timing setup 8 Restore timing setup 9 Silenc...

Page 3: ...fied engineer to handle the installation and setup of the Silence Sentinel Standard Broadcast Tools Inc is unable to support NON Broadcast Tools software hardware or NON Broadcast Tools computer hardw...

Page 4: ...Stereo output LED level display External Ext alarm trigger input with front panel LED indicator Front Panel Power Heartbeat LED Dipswitch selection of silence detection of 20 25 30 and 35dB below zer...

Page 5: ...perly protected For lightning protection devices check out www polyphaser com and www itwlinx com UPS Standby Power System We recommend that you connect your Silence Sentinel Standard to a UPS system...

Page 6: ...input s from the fixed output such as the tape monitor outputs Relay and Open Collector connections The K1 and K2 SPDT relays provide switch position tallies for the Silence Sentinel Standard K1 is cl...

Page 7: ...22K resistor and is considered active on when pulled low to ground All of the inputs except for the Ext input are triggered by momentary closure to ground For example pulsing the CH2 input to ground w...

Page 8: ...he unit The table below provides TWO second resolution settings To provide longer time resolution turn SW5 switch 9 ON which will provide 20 second resolution For the factory default setting as shown...

Page 9: ...The table below provides TWO second resolution settings To provide longer time resolution turn SW6 switch 7 ON which will provide 20 second resolution All seven switches are set at the factory for OFF...

Page 10: ...store to the primary input when valid audio returns to it With switcher bounce OFF SW5 10 OFF in Auto mode manual remote control will be required for the unit to switch back to input one after an alar...

Page 11: ...able safety push button can be enabled to require the user to hold down the enable push button while selecting any of the other front panel push buttons the enable LED is illuminated when this functio...

Page 12: ...put will de activate The K2 relay will open and the K1 relay will close When the Silence Sentinel Standard is in Manual manual switching mode the fol lowing actions will occur when silence is detected...

Page 13: ...ers momentary closure to ground Relays K1 and K2 SPDT dry contacts each 30 VDC 1 Amp CAUTION For safety never connect 120 Vac circuits to the above relays Open collector outputs Each output sinks 6 vd...

Page 14: ...dies NO OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED...

Page 15: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 15 APPENDIX...

Page 16: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 16 APPENDIX...

Page 17: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 17 APPENDIX...

Page 18: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 18 APPENDIX...

Page 19: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 19 APPENDIX...

Reviews: