3

Silence Sentinel

®

Basic Installation and Operation Manual

INTRODUCTION

INTRODUCTION

Thank you for your purchase of a Broadcast Tools® “Silence Sentinel®

Basic” (referred to as the Silence Sentinel® Basic throughout this manual). We’re
confident that this product will give you many years of dependable service. This
manual is intended to give you all the information needed to install and operate the
Broadcast Tools® “Silence Sentinel® Basic”.

SAFETY INFORMATION

Only qualified technical personnel should install Broadcast Tools products.

Any attempt to install this device by a person who is not technically qualified could
result in a hazardous condition to the installer or other personnel or damage
Broadcast Tools product or other equipment.  Please ensure that proper safety pre-
cautions have been taken before installing this device.  If you are unfamiliar with
this type of equipment, please contact a properly qualified engineer to handle the
installation and setup of the Broadcast Tools product.

Broadcast Tools, Inc., is unable to support NON-Broadcast Tools software, hard-

ware or NON-Broadcast Tools computer/hardware/software problems.  If you experience
these problems, please research your hardware/software instruction manuals or contact the
manufacturers technical support department.

WHO TO CONTACT FOR HELP

If you have any questions regarding your product or you need assistance,

please contact your distributor from whom you purchased this equipment.

If you would like more information about Broadcast Tools® products, you

may reach us at:

Broadcast Tools,  Inc.

131 State Street
Sedro-Woolley, WA 98284-1540 USA
Voice: 360.854.9559
Fax:

866.783.1742

Internet Home Page: www.broadcasttools.com
E-mail:

[email protected]

THANK YOU FOR CHOOSING 

BROADCAST TOOLS® BRAND PRODUCTS!

CAUTION!

Broadcast Tools®

Products, as with any
electronic device, can
fail without warning.
Do not use this product
in applications where a
life threatening condition
could result due to failure.

NOTE:

This manual should be
read thoroughly before
installation and operation.

WEBSITE:

Visit our web site for
product updates and
additional information.

Broadcast Tools is a Veteran Owned Business

Designed, Assembled and Supported in WA State, USA

Summary of Contents for Silence Sentinel Basic

Page 1: ...ntinel labeled products are registered trademarks of Broadcast Tools Inc Copyright 1989 2011 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed withou...

Page 2: ...s 6 Remote Disable Alarm Reset input 6 Power Heart beat LED 6 Programming Guidelines 6 Dipswitch Setup Grid 6 Delay timing setup 7 Restore timing setup 7 Trip input sensitivity level setup 7 Delay Res...

Page 3: ...roadcast Tools product Broadcast Tools Inc is unable to support NON Broadcast Tools software hard ware or NON Broadcast Tools computer hardware software problems If you experience these problems pleas...

Page 4: ...ro reference Dipswitch selection of time delay from OFF to 5 minutes in 2 or 20 seconds increments Dipswitch selection of restore timing delay from OFF 5 30 and 90 seconds Two independent SPDT alarm r...

Page 5: ...ough removable euroblock screw terminals The terminals accommodate wire sizes from 16 28 AWG solid or stranded wire Before installing a wire remove the euroblock screw terminal plug and turn each capt...

Page 6: ...Guidelines DIPSwitch Setup Locate dipswitch S1 on the front of the unit and follow the grid below Delay Time SW1 9 ON SW1 1 SW1 2 SW1 3 SW1 4 Restore SW1 5 SW1 6 Delay SW1 9 Delay Time Resolution OFF...

Page 7: ...ro Switches 7 and 8 are used to set the stereo or dual monaural trip levels The factory default is both switches OFF 20 We rec ommend setting the trip level to 25 for most installations Delay Resoluti...

Page 8: ...ed by JPR1 When both channels return and the restore time delay has expired if enable the fol lowing action occurs 1 K1 opens 2 The front panel OK LT and OK RT audio LED s will illuminate 3 Either or...

Page 9: ...ined closure to ground Pulled up to 5 VDC Relays K1 and K2 Each relay with SPDT dry contacts 30 VDC 1 Amp Connectors Removable euroblock screw terminals Power supply 7 5 VDC only 500ma or 1 Amp PS sup...

Page 10: ...ies NO OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED T...

Page 11: ...ntrolled Relay 5VDC 5VDC 1 Left Audio Input Control Processor and Stereo Silence Detector K1 7 5vdc external Power Supply supplied PS GND 2 Right Audio Input K2 1 Valid Left Audio OK LT 2 Valid Right...

Page 12: ...l SILENCE Sentinel Basic Loss of Audio Detector Audio Control Relay 131 State Street Sedro Woolley WA 98284 360 854 9559 Fax 866 783 1742 Visit us online at www broadcasttools com Copyright 1989 2010...

Page 13: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Silence Sentinel Basic Installation and Operation Manual 13 APPENDIX...

Page 14: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 14 Silence Sentinel Basic Installation and Operation Manual APPENDIX...

Reviews: