November 19, 2007
Changes to the Broadcast Tools® SM-III with version 1.16 firmware. Please check the label
on U4 for the correct firmware version.
Restore timing setup:
The SM III Plus restore time delay is set via SW 2, the first six positions of the dipswitch
and Jp-1 The default for this jumper is installed. This provides TWO second resolutions.
To provide longer time resolution, remove and stow Jp-1, which will provide 20 second res-
olution. The switches are set at the factory for off. Each switch has a digit value as shown
in the two tables below. For the factory default setting. Please note the table below refers
to the restore time delay in seconds.
NOTE 1, SW2-7 now has two independent functions.
When OFF, the SM-III switches back to input one from input two when the alarm is cleared
or the audio returns.
When ON it allows the SM-III to stay at input two after the alarm is cleared or the audio
returns.
NOTE 2, SW2-8 now has two independent functions.
When OFF, the SM-III is armed at start-up.
When ON, the SM-III is NOT armed at start-up.
AUX relay configuration
JP5 is used to select the Aux relays control function. Move the jumper between XFER
(transfer), PUL1 (Pulse 1) or PUL2 (Pulse 2). When configured, the Aux relay will follow