AES DA 2x6 Installation and Operation Manual

OVERVIEW

Product Overview

The AES DA 2×6, six output two-input AES/EBU distribution system follows in the
footsteps of the RDDA 4×4 product and is ideal for distributing AES/EBU signals
or word clock at sample rates of up to 192 kHz. The system provides two switch
selectable transformer isolated inputs, one with a female XLR connector for bal-
anced AES/EBU signals the other with an RCA for unbalanced S/PDIF signals. The
selected input is distributed to six transformer isolated AES/EBU XLR outputs.
Signal bypass is built-in with the XLR AES/EBU input passively routing to output
one in the event of power loss. Local and remote signal monitoring is provided by
an internal AES/EBU activity detector that will indicate the presence or loss of clock
with active and inactive front panel LED indicators and a SPDT alarm relay. The
alarm relay contacts are available on a rear panel plug-in euro-block connector. The
AES DA 2×6 is powered by a surge protected internal power supply. A 9 volt DC
universal switching power supply with domestic AC connector is included.
International AC connectors are optional. The compact half rack form-factor allows
the unit to be set on a desktop, mounted on a wall, or two units may be rack mount-
ed using the RA-1, Rack-Able mounting shelf.

WEBSITE:

Visit our web site for
product updates and
additional information.

Summary of Contents for AES DA 2x6

Page 1: ...oducts are registered trademarks of Broadcast Tools Inc Copyright 1989 2015 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed without permission Visit www broadcasttools com for important product update information Manual update 9 17 2015 If you need a firmware upgrade contact Broadcast Tools No part of this document may be reproduced or distribut...

Page 2: ...s 4 Inspection 5 Installation Operation 5 Surge Protection 5 UPS standby power system 5 Power 5 LED indicators 5 Input Select Switch 5 AES EBU and S PDIF Digital Audio Inputs 5 AES EBU Outputs 6 XLR Connector Pinout 6 AES EBU Activity Detector Alarm Relay 6 Specifications 7 Warranty 8 Front and rear panel drawings Appendix Connector layout Appendix Fractional schematic Appendix WEBSITE Visit our w...

Page 3: ...cast Tools Inc is unable to support NON Broadcast Tools software hardware or NON Broadcast Tools computer hardware software prob lems If you experience these problems please research your hardware software instruction manuals or contact the manufacturers technical support department WHO TO CONTACT FOR HELP If you have any questions regarding your product or you need assistance please con tact your...

Page 4: ...s is built in with the XLR AES EBU input passively routing to output one in the event of power loss Local and remote signal monitoring is provided by an internal AES EBU activity detector that will indicate the presence or loss of clock with active and inactive front panel LED indicators and a SPDT alarm relay The alarm relay contacts are available on a rear panel plug in euro block connector The ...

Page 5: ...nnector into the unit and the 9 to 12 VDC uni versal switching power supply with domestic AC connector into a 120 Vac 50 60 Hz power source NOTE Never use any type of power supply other than the specified supplied power supply LED Indicators Power LED Illuminates when power is applied Green Active LED Lit when an AES signal is detected on one of the inputs Green Inactive LED Lit when no AES signal...

Page 6: ...d signal is present the front panel Active LED will light the Inactive LED will extinguish and the alarm relay will open When AES signal is lost the front panel Inactive LED will light the Active LED will extinguish and the Alarm Relay will close The AES DA 2x6 has one SPDT alarm relay labeled Alarm Relay Connections should be made to the three position plugin euro block s NO normally open CM comm...

Page 7: ...uts 110 ohm impedance Sample Rate Up to 192 khz Outputs follow input sample rate Alarm Relay Output SPDT dry contacts 30 VDC 1 amp maximum CAUTION For safety never connect 120 Vac circuits to the above relay Power Requirements 9 to 12 VDC 660 mA CE certified universal switching 9 VDC adapter with domestic AC connector supplied International connectors optional Physical Dimensions 8 50 x 7 10 x 1 5...

Page 8: ... OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABIL ITY OR FITNESS FOR A PARTICULAR PURPOSE AND THE FOREGOING ALTERNATIVE REMEDIES SHALL BE EXCLUSIVE OF ALL OTHER REMEDIES THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RI...

Page 9: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 AES DA 2x6 Installation and Operation Manual 9 APPENDIX ...

Page 10: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 10 APPENDIX ...

Page 11: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 11 APPENDIX ...

Reviews: