*uSS
Sends status of silence sensor: SuS,a<CR><LF>
a = 1 = not silent, 0 is silent
*uU
Sends unit firmware version: <name><version><lf>
*uY
Display configuration.
*uZx
Echo character x to serial control port - for debugging command strings
*uCEx
Enable error and good responses if x = Y (default N)
*uCDEF
Reset to factory defaults.
*uCLx
Lock front panel: x = L (Lock) x = U (Unlock)
*uCIIttt
Sets PIP minimum pulse length ttt: 000 - 255 => off to 2.55 seconds.
*uCPS
Power up audio state: save power up state now
*uCSLx
Sets silence sensor detection threshold to Off, -20, -25, -30 dB (0,1,2,3)
*uCSAtttt
Sets silence sensor acquire delay to tttt seconds (0, 2-255)
*uCSBtttt
Sets silence sensor restore delay to tttt seconds (0, 2-255)
*uCSCtt
Sets step interval in seconds 1-99 seconds.
*uCSSt
Sets last step channel 1-4 (0 disables step feature.)
*uCSEi
Sets EAS controlled input channel (i) to 1-4 or 0 for off. This allows
you to assign one input channel that will be switched to with
sustained closure to ground on the PIP8/EAS remote control input
from an EAS encoder for EAS audio insertion with the ACS 4.1.
*uDxx
Delay xx seconds before processing next command.
*uDLxxx
Delay xxx seconds before processing next command.
Menu Operation
Broadcast Tools(R) ACS 4.1, v1.2 - Setup Menu
1 - Set PIP Minimum Hold Time(0 - 2.55 sec)
- Now:0.05
2 - Set Silence Sense Acquire Delay (sec)
- Now: 10
3 - Set Silence Sense Restore Delay (sec)
- Now: 2
4 - Set Silence Sense Threshold
- Now:-30 dBu
5 - Set Stepping Interval (sec 1-99)
- Now: 1
6 - Set Last Step Channel
- Now: 3
7 - Lock/Unlock Front Panel
- Now:UNLOCKED
8 - Set EAS input channel
- Now: 3
S - Turn ON audio input
M - Turn OFF audio
V - Save Audio Macro
L - Load Audio Macro
C - Show Configuration and Status
F - Set To Factory Defaults
To select a menu function, simply enter the letter on the left side of the menu and
wait for the prompt. Example: Type the letter “S” Response: Enter Input Channel:
Entering a 1 would select channel 1.