Broadcast Pix Slate 1000G Installation Planning Guide - 2012
Page
Control Panel Specifications
8
The control panel comes standard with one external power supply (upgrade to dual redundant power) that
uses standard IEC power cords (included). In addition, there are 2 redundant 100BASE-TX Category 5
network ports for communication to the workstation. One 10ft Cat 5 crossover network cable is included with
each Slate 1000G system.
The DB 9-pin serial connection is only used for control panel firmware upgrades on older control panels. New
Slate G Series systems use the network port for control panel firmware upgrades. It is not necessary to have
a serial cable connected during normal operation.
Rear View of 1 M/E Control Panel
Power supplies
(Redundant
supplies optional)
Redundant
network ports
for workstation
communication
18.5 in
47 cm
12.5 in
31.8 cm
12.5 in
31.8 cm
18.5 in
47 cm
Top View
Bottom View
RS
– 232
Serial port
for panel upgrades
Pin
Function
2
RXD
3
TXD
5
GND
DP 9-pin Serial Cable