2-11
2-71.
Remote Overload Indicator.
The remote overload indicator provides a signal to indicate
when a plate, screen, grid, or VSWR overload has occurred. The remote overload indicator
is located at TB1-23. The indicator will go LOW (0 volts dc) to indicate when an overload
has occurred.
2-72.
Remote Preset Power Indicator.
The preset power indicator provides a signal to indicate
when preset power operation is enabled. The preset power indicator is located at TB1-24.
The indicator will go LOW (0 volts dc) to indicate when preset power operation is enabled.
2-73.
Remote Failsafe Indicator.
The failsafe indicator provides a signal to indicate when the
failsafe interlock is closed. The failsafe indicator is located at TB1-26. The indicator will
go LOW (0 volts dc) to indicate when the failsafe interlock is closed.
2-74.
Remote Interlock Indicator.
The interlock indicator provides a signal to indicate when the
internal interlock is closed. The interlock indicator is located at TB1-27. The indicator
will go LOW (0 volts dc) to indicate when the internal interlocks are closed.
2-75.
Remote Blower Indicator.
The blower indicator provides a signal to indicate when the
transmitter blower is operational. The blower indicator is located at TB1-28. The indica
tor will go LOW (0 volts dc) to indicate when the blower is operational.
2-76.
Remote Filament Indicator.
The filament indicator provides a signal to indicate when the
filament contactor is energized. The filament indicator is located at TB1-29. The indica
tor will go LOW (0 volts dc) to indicate when the filament contactor is energized.
2-77.
Remote High Voltage Indicator.
The high voltage indicator provides a signal to indicate
when the high voltage contactor is energized. The high voltage indicator is located at
TB1-30. The indicator will go LOW (0 volts dc) to indicate when the high voltage contactor
is energized.
2-78.
Remote Forward Power Meter Indications.
Remote forward power meter indications are
located at TB2-1. The forward power meter output can be configured for a +2 or +4 volt
dc full-scale meter indication. The forward power full-scale indication is 5500 watts. In
addition, the forward power sample can be provided in a log or linear format. The trans
mitter is shipped with the sample programmed for a linear format. The meter ground is
recommended for remote metering connections (TB2-6 through TB2-8).
2-79.
Remote Reflected Power Meter Indications.
Remote reflected power meter indications
are located at TB2-2. The reflected power meter output can be configured for a +2 or +4
volt dc full-scale meter indication. The reflected power full-scale indication is 1540 watts.
In addition, the reflected power sample can be provided in a log or linear format. The
transmitter is shipped with the sample programmed for a linear format. The meter ground
is recommended for remote metering connections (TB2-6 through TB2-8).
2-80.
Remote Plate Voltage Meter Indications.
Remote plate voltage meter indications are lo
cated at TB2-4. The plate voltage meter output can be configured for a +2 or +4 volt dc
full-scale meter indication. The plate voltage full-scale indication is 6000 volts. In addi
tion, the plate voltage sample can be provided in a log or linear format. The transmitter is
shipped with the sample programmed for a linear format. The meter ground is recom
mended for remote metering connections (TB2-6 through TB2-8).
2-81.
Remote Plate Current Meter Indications.
Remote plate current meter indications are lo
cated at TB2-5. The plate current meter output can be configured for a +2 or +4 volt dc
full-scale meter indication. The plate current full-scale indication is 1.5 amps. In addi
tion, the plate current sample can be provided in a log or linear format. The transmitter is
shipped with the sample programmed for a linear format. The meter ground is recom
mended for remote metering connections (TB2-6 through TB2-8).
2-82.
Remote IPA Forward Power Meter Indications.
Not used in FM-5T/FM-5TS.
2-83.
Chassis Ground.
Chassis ground is designed to be used for remote control connections.
Chassis ground is located at TB2-13 and TB2-14.
2-84.
+15V DC Supply.
A +15 volt dc supply is provided for the remote control switches and in
dicators. The +15 volt dc supply is located at TB2-15 and TB2-16.
Summary of Contents for FM-5T
Page 1: ...FM 5T FM 5TS 5 KILOWATT FM BROADCAST TRANSMITTERS July 1999 IM No 597 0033 014 ...
Page 14: ...1 3 FIGURE 1 1 FM 5T FM 5TS TRANSMITTER 597 0033 1 COPYRIGHT 1990 BROADCAST ELECTRONICS INC ...
Page 29: ...2 13 COPYRIGHT 1997 BROADCAST ELECTRONICS INC 597 0033 415 FIGURE 2 4 TRANSFORMER TAPS ...
Page 32: ...2 16 597 0033 406 FIGURE 2 6 FM 5T PRIMARY AC WIRING COPYRIGHT 1997 BROADCAST ELECTRONICS INC ...
Page 46: ...3 9 TABLE 3 2 INDICATOR CHECKLIST 597 0098 412 ...
Page 61: ...4 19 FIGURE 4 5 PA CAVITY 597 0032 32 COPYRIGHT 1997 BROADCAST ELECTRONICS INC ...
Page 83: ...5 22 WARNING DISCONNECT POWER PRIOR TO SERVICING BLANK PAGE ...
Page 101: ......
Page 102: ......
Page 103: ......
Page 104: ......
Page 105: ......
Page 106: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ......
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 128: ......
Page 129: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 141: ......
Page 142: ......
Page 143: ......
Page 144: ......
Page 145: ......
Page 146: ......
Page 177: ......
Page 178: ......
Page 179: ......
Page 180: ......
Page 181: ......
Page 182: ......
Page 183: ......
Page 184: ......
Page 185: ......
Page 186: ......
Page 187: ......