Heatsink Mounting/Hardware 

 

Tips for Mechanical Mounting

 
1 All mounting holes designated in (X, Y) format are 0.156 inch thru and they are designed for a #6 Screws or 

metric equivalent. Stainless Steel mounting hardware is recommended, grade 18-8 or better. A lock washer of 
same material should also be used. 

2 Ensure mounting surface is flat to better than 0.0025”  
3 Use a thin layer of thermal compound on the backside of the PA - no more than 0.001” - 0.002” thickness! 

           4 Torque all screws to 10-12 in-lbs 
          

Warning: Failure to use a proper heat sink will reduce product service life and may cause the transistors to 
burn out. This type of failure is not covered by warranty. This product can be ordered with a custom heat 
sink. Please contact factory for more information.