5.0  SPECIFICATIONS

Video

Resolution

Up to 1080p@60Hz
and 1920x1200@60HZ

Connector

BNC, SDI Female Plug

Protocol

DDC/EDID/HDCP Capable

Audio

Channel Capacity

1 Stereo

Operating Mode

Unbalanced (Stereo Audio),
Unidirectional

Input/Output Impedance

10k/50 Ohms (Stereo Audio)

Max. Input/Output Level

5 dBu/4Vpp
(Stereo Audio)

Magnitude Freq. Response 20Hz to 20kHz @ -3dB

THD+N

>70 @ 1k Hz (Stereo Audio)

Connector

3.5mm Stereo Jack

Serial Data

Channel Capacity

2 RS-232/1 IR

Signal Format

RS-232/IR

Data Rate

Up to 57.6kbaud

Connector

Terminal Block

Transmission

Cable Type

CAT-5e/6 Shielded

Number of Cables

1

Connector

RJ45

Summary of Contents for LBH-SDI-EAD-T

Page 1: ...NVERTING TRANSMITTER SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent No liability is assumed as a result of their use or application All...

Page 2: ...erial number so that a specific medical device can be identified CLASS II ME EQUIPMENT Functional Earth Terminal Caution review manufacturer s documentation for instructions WARNING No modification of...

Page 3: ...t position the equipment so that is it is difficult to access the appliance coupler Class II Medical System No Applied Parts IP20 LBH Power Supply 80275 2401 24V 1 0A Power Supply For medical applicat...

Page 4: ...interference to other devices in the vicinity FCC Council Directives of European Standards and IEC There is no guarantee that interference will not occur in a particular installation If this equipment...

Page 5: ...raindications This device is not intended for life support applications Not suitable for use in an oxygen rich environment Operational Failure Conditions and Mitigation Operational Failure End user ca...

Page 6: ...ECTIONS 10 2 2 1 1 SDI VIDEO INTERFACE 10 2 2 1 2 AUDIO INTERFACE 11 2 2 1 3 SERIAL DATA INTERFACE 12 2 2 1 4 STATUS LED S 13 2 2 2 CAT 5e 6 CABLE CONNECTION 13 2 3 DC POWER CONNECTION 15 2 5 IN WALL...

Page 7: ...A 1920x1200 60Hz or 720p 1080i 1080p HDTV video resolution No user adjustment is required for the LBH SDI EAD T system due to the use of advanced digital HDBT transmission system technology with zero...

Page 8: ...Broadata Technical Support Sales Broadatacom com 9 Figure 1 2 LBH SDI EAD T Rear Panel 1 5AMP 24VDC LINK CAT 5e 6 Output Connector Power Connector FRONT PANEL STANDALONE REAR PANEL STANDALONE Figure...

Page 9: ...r System Broadata Technical Support 800 214 0222 10 FRONT PANEL WALL PLATE Figure 1 3 LBH SDI EAD T WP Front Panel REAR PANEL WALL PLATE Figure 1 4 LBH SDI EAD T WP Rear Panel 24V Power Connector CAT...

Page 10: ...k Figure 2 1 depicts a typical installation for the LBH SDI EAD T Figure 2 1 LBH SDI EAD T R Setup 2 1 Mounting Before installing the units into your housing make sure there is enough space to pull an...

Page 11: ...ace The SDI video connection is the SDI plug connectors for video input and output ports Use the following instructions to properly connect your component video as illustrated in Figure 2 2 1 Connect...

Page 12: ...ing steps illustrate the installation procedures for audio devices To send audio signals label and connect one stereo audio jack cable to the AUDIO OUTPUT connector and the line level audio receiver c...

Page 13: ...interface RS 232 IR Dataata The LBH SDI EAD T transmits two channels of data signals Follow the procedures for installing data terminal devices 1 Label and connect one serial data cable to the user s...

Page 14: ...on installing and connecting the CAT 5e 6 links 1 Ensure the power is off before proceeding with the CAT 5e 6 cable installation 2 It is recommended to use shielded CAT 5e 6 cabling 3 Connect the CAT...

Page 15: ...ridgeTM HDBT SDI Video ConvertingTransmitter System Broadata Technical Support 800 214 0222 16 Figure 2 6 CAT 5e 6 Connection LBH SDI EAD T LBH HDMI EAD R LBH SDI EAD T WP LBH HDMI EAD R WP 1 5AMP 24V...

Page 16: ...es not suffer from voltage variations 4 Power Surge Protection This is optional but highly recommended A UPS system provides voltage regularity as well as prevents spikes from occurring thus protectin...

Page 17: ...e 6 and power cables through the opening of the wall box and secure the cables with cable clamps to provide strain relief 2 Terminated CAT 5e 6 with RJ45 connector to be directly plugged into the RJ45...

Page 18: ...nsmitter System Broadata Technical Support Sales Broadatacom com 19 Figure 2 7 In wall CAT 5e 6 power cable installation Figure 2 8 Power Connection LBH DVI EAD WP Unit Clamp Power Wire CAT 5e 6 Cable...

Page 19: ...2 or a Listed ITE Power Supply marked rated as LPS or Limited Power Source Note 2 The installation shall be in accordance with the applicable provisions of the National Electrical Code ANSI NFPA 70 Ar...

Page 20: ...indicated in the previous sections The following describes the LED activity LED Indicator Description PWR LINK When power is connected this LED turns RED When power and link are on this LED turns GRE...

Page 21: ...lems persist that may be fiber related contact BCI at 1 800 214 0222 for further assistance For electrical problems perform the following troubleshooting procedures 1 If the POWER indicator is OFF che...

Page 22: ...echnical Support Sales Broadatacom com 23 b Both ends of the link are connected to the corresponding equipment and to the same corresponding channel port c Cable connections at both the video audio ch...

Page 23: ...o Channel Capacity 1 Stereo Operating Mode Unbalanced StereoAudio Unidirectional Input Output Impedance 10k 50 Ohms StereoAudio Max Input Output Level 5 dBu 4Vpp StereoAudio Magnitude Freq Response 20...

Page 24: ...Dimension Standalone 4 17 W x 4 1 D x 1 1 H Wallplate 1 69 W x 2 70 D x 2 81 H Power Level max 24VDC 1 0A Operating Temperature 0 to 50o C Humidity 0 to 95 RH non condensing LBH SDI EAD T HDBTTransmi...

Page 25: ...AD T System contains no user serviceable components If you have a problem with your unit please contact the Customer Service Department To facilitate our return repair processing please contact Broada...

Page 26: ...and do not include malfunctions or failure resulting from misuse abuse neglect alterations electrical power problems usage not in accordance with product instructions improper installation or damage d...

Page 27: ...LBH SDI EAD T User s Manual Link BridgeTM HDBT SDI Video ConvertingTransmitter System Broadata Technical Support 800 214 0222 28...

Page 28: ...Communications Inc 2545 West 237th Street Suite K Torrance CA 90505 1 800 214 0222 310 530 1416 310 530 5958 Facsimile e mail CustomerService Broadatacom com Website www broadatacom com 60000 LBHSDI E...

Reviews: