Broadata LBH-H-T/R-EAD-ICP Manual Download Page 26

LBH-H-T/R-EAD-ICP User Manual

Link Bridge

TM

 

HBaseT HDMI Transmission System w/External Audio and Inline Control Processor

Broadata Technical Support, [email protected]

27

Configure IR Code

The 

Configure IR Code

 page is used to learn and manage IR codes in

the ICP.  To learn an IR code, type in the label of the IR code in 

New

Label

 and click the 

Learn

 button.  Once IR Learn mode is initiated, the

user needs to present an IR signal to the IR receiver port within 30
seconds.  If a valid IR code is not presented within 30 seconds, the IR
learn process will timeout and the process will need to be re-initiated.
After an IR code is learned successfully, it will be stored in memory and
appear in the 

IR Preset

 drop down menu.  To test a learned IR code,

select the IR code from the IR Preset menu and click 

Test

 button.

Verify that the IR code works correctly on the target device.  To delete
an IR code from the IR Preset menu, select the desired IR code and
click the 

Delete

 button.

On the top menu click 

Configure

 and then click 

IR Code

.

  

The following

page will be displayed:

Summary of Contents for LBH-H-T/R-EAD-ICP

Page 1: ...H EXTERNAL AUDIO AND INLINE CONTROL PROCESSOR BCI reserves the right to make changes to the products described herein without prior notice or consent No liability is assumed as a result of their use o...

Page 2: ...Y INSTRUCTIONS AND COMPLIANCE DECLARATIONS PLEASE OBSERVE THE FOLLOWING SAFETY PRECAUTIONS SURGE PROTECTION DEVICE RECOMMENDED This product contains sensitive electrical components that may be damaged...

Page 3: ...ND FUNCTIONS 6 2 1 TRANSMITTER EXTENDER FRONT AND REAR PANELS 6 2 2 RECEIVER EXTENDER FRONT AND REAR PANEL 7 2 3 ICP FRONT AND REAR PANEL 8 3 0 CONNECTOR PINOUT ASSIGNMENT 9 3 1 EXTENDER 9 3 1 1 SERIA...

Page 4: ...e 6 cable Full HDTV video resolution for 4K2K and 1080p 1080i 720p Fully uncompressed video and audio provides zero loss of quality Supports True DDC EDID HDCP transmission Bi directional POH Inline C...

Page 5: ...00 214 0222 6 2 0 OPERATION CONTROLS AND FUNCTIONS 2 1 Transmitter Extender Front and Rear Panel 1 Power Link The red LED indicates the unit is powered up The green LED indicates that the unit has a g...

Page 6: ...ough IR connector 8 SPDIF SPDIF audio input connector 9 L R L R audio input connector 10 HDMI IN HDMI video input connector 11 HDBT HDBT CAT 5e 6 7 cable connector 2 2 Receiver Extender Front and Rear...

Page 7: ...al I O Digital input output ports 2 Digital I O LEDs Light when the corresponding ports are active high 3 RS 232 Serial port to control devices 4 RS 232 LEDs Light when the corresponding RS 232 ports...

Page 8: ...nector 17 RESET Press the button to reset the device back to factory default settings 3 0 CONNECTOR PINOUT ASSIGNMENT 3 1 Extender 3 1 1 Serial Data Interface Each LBH H EAD ICP unit can be used for R...

Page 9: ...ether a given signal is present for transmission and aid in the troubleshooting process if a given signal is missing HDCP LED Will be solid LED when video input has a HDCP It will blink when video inp...

Page 10: ...Normally Open Relay 1 Common Relay 1 Normally Closed Reserved Do Not Connect Reserved Do Not Connect Digital I O LEDs 1 I O Ch 1 2 I O Ch 2 Remote LED On Remote IR TX LED On IR TX Act On High Level R...

Page 11: ...holes Reset button push to reset to default settings RJ 45 1 TX 2 TX 3 RX 4 N C 5 N C 6 RX 7 N C 8 N C CONFIG Keypad 1 12V keypad power 2 RS 232 IN 3 RS 232 OUT 4 GND IR Learn LED ON in IR Learn mode...

Page 12: ...al Support Sales Broadatacom com 13 The cable connection between LB KP8 and LB ICP is shown below IR Learner CONFIG LAN RESET 1 IR Out 1 12VDC SW ON Standard RJ45 Termination T 568B 2 White Orange RS2...

Page 13: ...and IR code import A standard web browser can be used to access the web pages Accessing Web Server The IP address of the ICP must be obtained in order to access the Web Server There are 2 ways to obta...

Page 14: ...em page On the top menu bar click Configure and then click System This brings up the ICP Login page In the ICP Login type in admin for the Userid and admin for the Password and then click Sign in butt...

Page 15: ...trol Processor Broadata Technical Support 800 214 0222 16 Configure System The Configure System page is used to configure the local unit s virtual keypad RS 232 channels Digital IO channels and remote...

Page 16: ...RS 232 channels Channel Select channel 1 2 or 3 Note Channel 3 is only available on LBC ICP and EAD SCL ICP units Channel 1 2 RS 232 control channels Channel 3 RS 232 control channel or pass through...

Page 17: ...a contact closure type output For example if a digital output is set to Open Collector setting the Digital Output State to 1 High will emulate a switch closure to ground Setting the Digital Output St...

Page 18: ...Output actions are only available if Digital IOs are configured as outputs in the Configure System page On the top menu click Configure and then click KeyAction The following page will be displayed Fu...

Page 19: ...ical Support 800 214 0222 20 Spacing Enter the delay in seconds desired before the command action Action Type Select the action type Available types are None Relay Digital Output RS 232 IR and Telnet...

Page 20: ...ssor Broadata Technical Support Sales Broadatacom com 21 Digital Output Options Digital Output Channel Select the digital output channel 1 or 2 Note this option is not available if both Digital IO cha...

Page 21: ...a Technical Support 800 214 0222 22 RS 232 Options RS 232 Channel Select channel 1 2 or 3 Remote Transmit String Type in the text string to be transmitted Strings are terminated with CR LF depending o...

Page 22: ...ystem w External Audio and Inline Control Processor Broadata Technical Support Sales Broadatacom com 23 IR Options IR Preset Select from list of IR commands stored in memory IR commands must be learne...

Page 23: ...line Control Processor Broadata Technical Support 800 214 0222 24 Telnet Options IP Address Enter IP address of telnet server IP Port Enter port number of telnet server The default port number is 23 U...

Page 24: ...t from telnet server Only the last 9 characters of the command prompt are needed Leave blank if there is no command prompt Note Check box below if stgring is used as a one time greeting Commands Enter...

Page 25: ...Auto Actions The following page will be displayed Trigger Select the auto action trigger Available triggers are Video Detect Digital Input 1 Digital Input 2 RS 232 Channel 1 Channel 2 Telnet Trigger 1...

Page 26: ...to the IR receiver port within 30 seconds If a valid IR code is not presented within 30 seconds the IR learn process will timeout and the process will need to be re initiated After an IR code is learn...

Page 27: ...The Configure IR Code Import page is used to import an IR pronto code Once a code is imported it will be stored in memory and is available as an IR Preset It can be tested in the Configure IR Code pag...

Page 28: ...Click the Details button next to Key Action Definitions to display the Key Action settings details Click the Details button next to Auto Action Definitions to display AutoAction settings details Click...

Page 29: ...anual Link BridgeTM HBaseT HDMI Transmission System w External Audio and Inline Control Processor Broadata Technical Support 800 214 0222 30 Click the Key Action Definitions Details button and the fol...

Page 30: ...ystem w External Audio and Inline Control Processor Broadata Technical Support Sales Broadatacom com 31 Click the Auto Action Definitions Details button and the following will be displayed Click the I...

Page 31: ...sor Broadata Technical Support 800 214 0222 32 Examples Example 1 This example configures the F1 key on the virtual keypad as a toggle key to turn on off Relay channel 1 On the top menu click Configur...

Page 32: ...w External Audio and Inline Control Processor Broadata Technical Support Sales Broadatacom com 33 Configure F1 Key toggle release action to turn Relay channel 1 Off as follows Click Submit Changes On...

Page 33: ...AUDIO TRANSMISSION Channel Capacity 1 Stereo Operating Mode Unbalanced Stereo Audio SPDIF Input Output Impedance 10k 50 Ohms Stereo Audio Max Input Output Level 5 dBu 4Vpp Stereo Audio Magnitude Freq...

Page 34: ...TOIP Telnet RS 232 CONTROL Channel Capacity 2 no flow control or 1 with RTS CTS flow control Baud Rate 2400 to 115200 baud 9600 baud default 8 data bits 1 stop bit no parity Connector Terminal block D...

Page 35: ...3 5 mm jack for IR blaster Carrier Frequency 30 kHz to 60 kHz Output 30 kHz to 60 kHz IR learning IR Learning 2 inches captive distance from panel RELAY CONTROL Channel Capacity 2 normally open norma...

Page 36: ...e The Link Bridge LBH H T R EAD ICP System contains no user serviceable components If you have a problem with your unit please contact the Customer Service Department To facilitate our return repair p...

Page 37: ...normal use and do not include malfunctions or failure resulting from misuse abuse neglect alterations electrical power problems usage not in accordance with product instructions improper installation...

Page 38: ...LBH H T R EAD ICP User Manual Link BridgeTM HBaseT HDMI Transmission System w External Audio and Inline Control Processor Broadata Technical Support Sales Broadatacom com 39...

Page 39: ...LBH H T R EAD ICP User Manual Link BridgeTM HBaseT HDMI Transmission System w External Audio and Inline Control Processor Broadata Technical Support 800 214 0222 40...

Page 40: ...LBH H T R EAD ICP User Manual Link BridgeTM HBaseT HDMI Transmission System w External Audio and Inline Control Processor Broadata Technical Support Sales Broadatacom com 41...

Page 41: ...ta Communications Inc 2545 West 237th Street Suite K Torrance CA 90505 1 800 214 0222 310 530 1416 310 530 5958 Facsimile e mail CustomerService Broadatacom com Website www broadatacom com 60000 LBHHE...

Reviews: