3. Installation
Page 12
March 2006
P/N 760-000718 Rev A
Table 4.
RU Number Dipswitch Setting
RU
DipswitcH
Number
3
4
5
6
7
1
Right Right Right Right Right
2
Left Right Right Right Right
3
Right Left Right Right Right
4
Left Left Right Right Right
5
Right Right Left Right Right
6
Left Right Left Right Right
7
Right
Left Left Right
Right
8
Left Left Left Right
Right
9
Right Right Right Left Right
10
Left Right Right Left Right
11
Right
Left Right
Left Right
12
Left Left Right
Left Right
13
Right
Right
Left Left Right
14
Left Right
Left Left Right
15
Right
Left Left Left Right
16
Left Left Left Left Right
17
Right Right Right Right Left
18
Left Right Right Right Left
19
Right Left Right Right Left
20
Left Left Right Right Left
21
Right Right Left Right Left
22
Left Right Left Right Left
23
Right
Left Left Right
Left
24
Left Left Left Right
Left
25
Right Right Right Left Left
26
Left Right Right Left Left
27
Right
Left Right
Left Left
28
Left Left Right
Left Left
29
Right
Right
Left Left Left
30
Left Right
Left Left Left
31
Right
Left Left Left Left
32
Left Left Left Left Left
3.2.3. System
Number
Settings
When using multiple CU systems (more than one CU over SDH rings), each CU
and RU must be assigned a number by configuring dipswitches 9 and 10 on the
backplane.
Table 5 details the dipswitch settings for each of the possible system number
options. For example, to set a CU/RU as System #1, set dipswitches 9 and 10 to
the right.
Note:
One CU in the multi CU system must be numbered as “1”.