INSTALLATION OF ALARM
The CO alarm shall be a BRK Model CO910 and shall provide at a minimum the
following features and functions:
1. An electrochemical CO sensor.
2. The unit shall be capable of self restoring.
3. Powered by a sealed 10-year lithium powercell with a tamperproof design. The
tamperproof design shall not allow the powercell to be removed. A low power
warning indicator shall cause the alarm to “chirp” when it reaches the end of
its service life and needs to be replaced. Upon end of life, the unit shall meet UL
requirements for disabling the alarm and the non-reinstallation of unit to
mounting bracket.
4. A visual LED power-on indicator to confirm unit is receiving power or is in alarm.
5. A full function test button. The test button should check all alarm functions by
stimulating the chamber to simulate a CO condition, causing the unit to alarm.
6. Two Silence features - Low Battery Silence: Silence low battery chirp for up to 8
hours. Alarm Silence: Temporarily silence unwanted nuisance alarms.
7. A tamper resistant locking pin that locks alarm to the mounting bracket.
8. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and
relative humidity between 10% and 90%.
9. The unit shall contain mounting hardware and shall be listed for wall or ceiling
mounting.
10. The unit shall at a minimum meet the requirements of UL2034, CSFM, NFPA 720,
NFPA 101, ICC.
Alarm Dimensions: 4.92”L x 4.92”W x 0.96”H
Weight:
4.8 oz
Operating Voltage:
3V Lithium Power Cell
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range:
10% to 95% relative humidity (RH)
Audio Alarm:
85dB at 10 feet
Test/Silence:
Electronically simulates CO condition, causing the unit
to alarm. Press and hold test/silence button.
Alarm Reset:
Automatic when CO clears
CO Sensor:
Electrochemical
Indicator Lights/Sounds:
DC Power:
Intermittent Red LED
Local Alarm:
Audio Alarm, rapidly flashing red LED
Listing:
Listed to UL2034 Standard
Individual Carton Dimensions
4.94 ”L x 1.31”D x 6.63”H
Weight
0.4 lbs.
Cube
0.03 ft3
UPC
0 29054 01334 7
Master Carton Dimensions
10.50 ”L x 8.13”W x 6.38”H
Master Pack
12
Weight
5.3 lbs.
Cube:
0.32 ft3
I2of5:
200 29054 01334 1
Pallet Information
Cases per Layer
19
Number of Layers:
8
Cases per Pallet:
152
Units per Pallet:
1,824
Cube:
62.2 ft3
Weight:
869 lbs.
©2013 BRK Brands, Inc. a Jarden Corporation
Company (NYSE: JAH)
3901 Liberty Street Road
Aurora, IL 60504-8122
All rights reserved
First Alert is a registered trademark of the First Alert Trust
BRK is a registered trademark of BRK Brands, Inc.
CM3183
brkelectronics.com
Installation of this smoke alarm must conform to NFPA 720. Always check your local
building codes. Follow all instructions for placement as outlined in the user’s manual in
sections titled “Recommended Locations for CO Alarms” and “Locations to Avoid for CO
Alarms”.
THE PARTS OF THIS CO ALARM
1. Test/Silence button
2. LED alarm light
3. Activate/Deactivate Switch
4. Locking tab slot (Break out Tab)
5. Locking tab
6. Mounting bracket
7. “This way up” Arrow
8. Mounting Slots
MOUNTING
BRACKET
TOP VIEW
SIDE VIEW
4.9”
4.3”
4.9”
1”
4.3”
1
2
3
4
5
6
7
8
8
Activate/Deactivate
Switch-Detail
Break and remove tab then
slide switch to deactivate
OFF - ON - DISCHARGE