WHAT YOU NEED TO KNOW ABOUT CO

WHAT IS CO?

CO is an invisible, odorless, tasteless gas produced when fossil fuels do not burn completely, or are exposed to
heat (usually fire). Electrical appliances typically do not produce CO.

These fuels include: 

Wood, coal, charcoal, oil, natural gas, gasoline, kerosene, and propane. 

Common appliances are often sources of CO. If they are not properly maintained, are improperly ventilated, or
malfunction, CO levels can rise quickly. CO is a real danger now that homes are more energy efficient. “Air-
tight” homes with added insulation, sealed windows, and other weatherproofing can “trap” CO inside.

SYMPTOMS OF CO POISONING

These symptoms are related to CO POISONING and should be discussed with ALL household members.

Mild Exposure:

Slight headache, nausea, vomiting, fatigue (“flu-like” symptoms).

Medium Exposure: 

Throbbing headache, drowsiness, confusion, fast heart rate.

Extreme Exposure:

Convulsions, unconsciousness, heart and lung failure. Exposure to Carbon Monoxide can

cause brain damage, death.

This CO Alarm measures exposure to CO over time. It alarms if CO levels are extremely high in a short period of
time, or if CO levels reach a certain minimum over a long period of time. The CO Alarm generally sounds an
alarm before the onset of symptoms in average, healthy adults.

Why is this important? Because you need to be warned of a potential CO problem while you can still react in time.
In many reported cases of CO exposure, victims may be aware that they are not feeling well, but become disorient-
ed and can no longer react well enough to exit the building or get help. Also, young children and pets may be the
first affected. The average healthy adult might not feel any symptoms when the CO Alarm sounds. However, people
with cardiac or respiratory problems, infants, unborn babies, pregnant mothers, or elderly people can be more
quickly and severely affected by CO. If you experience even mild symptoms of CO poisoning, consult your doctor
immediately!

FINDING THE SOURCE OF CO AFTER AN ALARM

Carbon monoxide is an odorless, invisible gas, which often makes it difficult to locate the source of CO after an
alarm. These are a few of the factors that can make it difficult to locate sources of CO:

• House well ventilated before the investigator arrives.
• Problem caused by “backdrafting.”
• Transient CO problem caused by special circumstances.

Because CO may dissipate by the time an investigator arrives, it may be difficult to locate the source of CO.

BRK Brands, Inc. shall not be obligated to pay for any carbon monoxide investigation or service call.

POTENTIAL SOURCES OF CO IN THE HOME

Fuel-burning appliances like:

portable heater, gas or wood burning

fireplace, gas kitchen range or cooktop, gas clothes dryer.

Damaged or insufficient venting:

corroded or disconnected water

heater vent pipe, leaking chimney pipe or flue, or cracked heat
exchanger, blocked or clogged chimney opening.

Improper use of appliance/device:

operating a barbecue grill or

vehicle in an enclosed area (like a garage or screened porch).

Transient CO Problems:

“transient” or on-again-off-again CO 

problems can be caused by outdoor conditions and other special
circumstances.

The following conditions can result in transient CO situations:

1. Excessive spillage or reverse venting of fuel appliances caused by outdoor conditions such as:

• Wind direction and/or velocity, including high, gusty winds. Heavy air in the vent pipes (cold/humid air with

extended periods between cycles).

• Negative pressure differential resulting from the use of exhaust fans.
• Several appliances running at the same time competing for limited fresh air.
• Vent pipe connections vibrating loose from clothes dryers, furnaces, or water heaters.
• Obstructions in or unconventional vent pipe designs which can amplify the above situations.

2. Extended operation of unvented fuel burning devices (range, oven, fireplace).
3. Temperature inversions, which can trap exhaust close to the ground.
4. Car idling in an open or closed attached garage, or near a home.
These conditions are dangerous because they can trap exhaust in your home. Since these conditions can come
and go, they are also hard to recreate during a CO investigation.

HOW CAN I PROTECT MY FAMILY?

A CO Alarm is an excellent means of protection. It monitors the air and sounds a loud alarm before carbon
monoxide levels become threatening for average, healthy adults.

A CO Alarm is not a substitute for proper maintenance of home appliances.

To help prevent CO problems and reduce the risk of CO poisoning:

• Clean chimneys and flues yearly. Keep them free of debris, leaves, and nests for proper air flow. Also,

have a professional check for rust and corrosion, cracks, or separations. These conditions can prevent
proper air movement and cause backdrafting. Never “cap” or cover a chimney in any way that would
block air flow.

• Test and maintain all fuel-burning equipment annually. Many local gas or oil companies and HVAC 

companies offer appliance inspections for a nominal fee.

• Make regular visual inspections of all fuel-burning appliances. Check appliances for excessive rust and

scaling. Also check the flame on the burner and pilot lights. The flame should be blue. A yellow flame
means fuel is not being burned completely and CO may be present. Keep the blower door on the furnace
closed. Use vents or fans when they are available on all fuel-burning appliances. Make sure appliances are
vented to the outside. Do not use grills or barbecue indoors, or in garages or on screen porches.

• Check for exhaust backflow from CO sources. Check the draft hood on an operating furnace for a 

backdraft. Look for cracks on furnace heat exchangers.

• Check the house or garage on the other side of shared wall.
• Keep windows and doors open slightly. If you suspect that CO is escaping into your home, open a 

window or a door. Opening windows and doors can significantly decrease CO levels.

UNDERWRITERS LABORATORIES INC. UL2034

WHAT LEVELS OF CO CAUSE AN ALARM?

Underwriters Laboratories Inc. Standard UL2034 requires residential CO Alarms to sound when exposed to lev-
els of CO and exposure times as described below. They are measured in parts per million (ppm) of CO over
time (in minutes).

UL2034 Required Alarm Points*:

• If the Alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN 4 and 15 MINUTES
• If the Alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN 10 and 50 MINUTES.
• If the Alarm is exposed to 70 ppm of CO, IT MUST ALARM BETWEEN 60 and 240 MINUTES.

* Approximately 10% COHb exposure at levels of 15% to 95% Relative Humidity (RH).

The unit is designed not to alarm when exposed to a constant level of 30 ppm for 30 days.

CO Alarms are designed to alarm before there is an immediate life threat. Since you cannot see or smell CO,
never assume it’s not present.

• An exposure to 100 ppm of CO for 20 minutes may not affect average, healthy adults, but after 4 hours

the same level may cause headaches.

• An exposure to 400 ppm of CO may cause headaches in average, healthy adults after 35 minutes, but can

cause death after 2 hours.

Standards:

Underwriters Laboratories Inc. Single and Multiple Station carbon monoxide alarms UL2034.

According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon monoxide alarms covered by
these requirements are intended to respond to the presence of carbon monoxide from sources such as, but
not limited to, exhaust from internal-combustion engines, abnormal operation of fuel-fired appliances, and
fireplaces. CO Alarms are intended to alarm at carbon monoxide levels below those that could cause a loss
of ability to react to the dangers of Carbon Monoxide exposure.” This CO Alarm monitors the air at the
Alarm, and is designed to alarm before CO levels become life threatening. This allows you precious time to
leave the house and correct the problem. This is only possible if Alarms are located, installed, and maintained
as described in this manual.

Gas Detection at Typical Temperature and Humidity Ranges:

The CO Alarm is not formulated to detect CO

levels below 30 ppm typically. UL tested for false alarm resistance to Methane (500 ppm), Butane (300 ppm),
Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm).
Values measure gas and vapor concentrations in parts per million.

Audible Alarm:

85dB minimum at 10 feet.

Summary of Contents for CO5120BN

Page 1: ... gas at the sensor Carbon monoxide gas may be present in other areas This unit does not work without power If the AC power fails the battery back up will power the alarm for at least 7 days provided the 9V battery is fresh and correctly installed The Silence Feature is for your convenience only and will not correct a CO problem Always check your home for a potential problem after any alarm Failure...

Page 2: ...f the bedrooms For added protection install additional CO Alarms in each separate bedroom and on every level of your home If your bedroom hallway is longer than 40 feet 12 meters install a CO Alarm at BOTH ends of the hallway In a Single level Home Install at least one CO Alarm near or within each separate sleeping area For added protection install an additional CO Alarm at least 20 feet 6 meters ...

Page 3: ...K HAZARD Do not restore power until all Alarms are completely installed Restoring power before installation is complete may result in serious electrical shock injury or death SPECIAL REQUIREMENTS FOR INTERCONNECTED CO ALARMS Failure to meet any of the above requirements could damage the units and cause them to mal function removing your protection AC and AC DC CO Alarms can be interconnected Under...

Page 4: ... the circuit breaker or fuse box Next remove the battery from Alarms with battery back up Finally press and hold the test button for 5 10 seconds to discharge the branch circuit 1 Remove the CO Alarm from the mounting bracket If the unit is locked to the bracket see the section To Deactivate the Locking Feature 2 Disconnect the power connector by gently prying it away from the back of the CO Alarm...

Page 5: ...rs the low battery chirp will resume Replace the battery as soon as possible to maintain protection in the event of a power outage THE LATCHING ALARM INDICATOR The Latching Alarm Indicator is activated after a CO Alarm is exposed to alarm levels of carbon monoxide After CO levels drop below alarm levels the red LED will begin to flash once every 5 seconds It will continue to flash or latch until y...

Page 6: ...use they can trap exhaust in your home Since these conditions can come and go they are also hard to recreate during a CO investigation HOW CAN I PROTECT MY FAMILY A CO Alarm is an excellent means of protection It monitors the air and sounds a loud alarm before carbon monoxide levels become threatening for average healthy adults A CO Alarm is not a substitute for proper maintenance of home applianc...

Page 7: ...ay reads Err Based on its Self Test diagnostics the unit has detected a malfunction The unit needs to be replaced Make sure a fresh 9V battery is installed If unit still isn t functioning REPLACE IT Units under warranty should be returned to manufacturer for replacement See Limited Warranty for details CO Alarm sounds frequently even though no high levels of CO are revealed in an investigation The...

Reviews: