1.4 BX315 Technical Information
AGA Approval No.: 8159
Energy Label Star Rating: 3.9
stars
152 MJ/m3/Year
Dimensions
Width
Height
Depth
Weight
Cabinet
420
850
775
57Kg
Duct Connection
300mm
Gas Type Natural Gas
Input (max)
68MJ/h
Output (max
)
15kW
Burner Pressure (max)
0.85KPa
Gas Injector Orifice
Main Burner
2.25mm
Fan Motor
Model
Fasco
Model No.
808555MVA-A22
Watts
250 Watts
Amps
1.80Amps
Capacitor
6uF
Fan Impellor Size
255mm x 180mm (9” X7”)
Combustion Fan:
Model.
Fime GRO4100
Model No.
FL120042Y - 13
Watts.
60 Watts
Amps
0.55 Amps
Resistance
40.6
Ω
Pressure switch
115pa
Return Air Grille Size
With Filter
0.35m2
No Filter
0.24m2
Airflow @ Total Static Pressure
50 Pa
75 Pa
100 Pa
125 Pa
Standard
620l/s
590l/s
560l/s
530l/s
Gas Valves:
VR8215S,T Honeywell
Main Burner:
.
In shot Burner
Ignition System
Tytronics HCDSI24-1DT control box
– Intermittent Sparking Pilot.
Heat Exchanger:
Aluminised Steel Tubes
Control Fuse:
2 Amp type 3AG. Slow blow
Transformer:
Model B024702 240 – 24/12V, 50HZ, 1.75Amps
.
Over Temperature Switch:
Supply Air Compartment
: Texas Inst Klixon Oil 1747 L110 (opens at 110oC).
Flame Roll-Out Sensor (AFRO):
Texas Inst Klixon Oil 1747 L90 (opens at 90oC).
.
Electronic Heater Controller:
Tytronics HCDSI24-1DT
FEATURES:
Tytronics HCDSI24-1DT control box with LED diagnostic display, flame roll-out Klixon , direct main in-shot burners, induced
combustion airflow, circulation air fan has an optional 3 speeds for heating. Wiring terminal connection for thermostat / system
with heat.