13 Replacement of Parts
13.16 Condensate Trap and Siphonic Drain
Refer to diagram 13.7.
Remove the clips securing the flexible tubes to the adapter by
twisting the clips slightly to disengage the clip jaws from each
other.
Remove flexible tubes from adapter.
Lift off the adapter.
Remove the drain connection downstream of the condense
trap.
Remove the two condense trap securing screws. Lift up and
carefully remove the condense trap taking care not to spill any
water which may be left in the unit. As the unit is lifted remove
the flexible pipe on the outlet.
Remove any solids found.
Before removing the float note it's orientation.
Remove the float to clean it.
Flush water through the trap to remove any remaining solids.
Check for any debris in the outlet pipe of the condensate drain
and clean as necessary.
Reassemble and refit the condensate trap.
IMPORTANT: Please remove spigot bung before fitting
condensate drain connection.
Using a suitable container, flush the heat exchanger until the
water appears clear in the container.
Reassemble adapter.
13.17 Inner Casing Sealing Panel
Refer to section 11.9.
13.18 Access to Switches, User Interface and
230v controls Interface
For access, refer to section 13.1.
Release the front of the controls fascia by carefully prising up
the two retaining latches, see diagram 11.10.
Do not allow the front of the fascia to swing down and be loosely
held by the electrical connections to the mains reset switch and
user interface. Either remove the connections or support the
fascia.
13.19 Mains Reset Switch
Refer to section 13.18 for access.
Remove electrical leads.
Lift the switch cover.
Remove switch, see diagram 13.8.
Diagram 13.8
ELECTRICAL
CONNECTIONS
SWITCH
SWITCH COVER
12220
Diagram 13.7
12962
SPIGOT
BUNG
(remove
and discard)
SPIGOT
SIPHON
ADAPTER
FLOAT
SCREW
CONDENSATE TRAP
AND SIPHONIC DRAIN