ENGLISH
OPERATION MANUAL
BRITEQ
®
4/5
BT-FEVERCAM2 PRO
16. ALARM PICTURES:
when the Save Record function is switched on: the images with the controlled
people will be displayed here.
17. HISTORY:
when Save Record of alarm pictures is switched on, more
‘alarm’ images can be found
here.
OPERATING INSTRUCTIONS
This product can work in an environment of 10°C to 50°C. For a accurate measurements, we advise to use
the unit in an environment between 10°C and 40°C.
To ensure accuracy, please avoid wind, rain and direct sunlight.
SETTINGS
Click on the [Set] tab in the upper left corner to open the setting window
•
VISUAL CAMERA SETTING
o
Mirror: use this function to mirror the image of both camera
’s on the screen (left and right of
each image are inverted)
o
Mask Detection: when switched on, the camera will also check if people are wearing a mask.
If they are not, an audio message (please wear mask) will also be played. This function /
warning can be switched on or off.
o
Save Record: images can be displayed and stored. When it is not allowed to use this
function (local privacy regulations) it can be switched off.
▪
ON: images will be displayed on the screen and they will also be stored in the
Android Box.
▪
OFF: no images will be displayed or stored.
•
IR CAMERA SETTING
o
Pseudo Color: several display color modes are available. Select the one you prefer
o
Temperature Type: select the unit in which the temperature is displayed
o
IR Display Mode:
▪
ON: normal camera image + thermal camera image will both be shown on the
screen.
▪
OFF: only the normal image will be displayed on the screen. The camera image of
the thermal camera will not be displayed anymore, but the measured information
(temperature / mask) will still be shown on the normal camera image.
•
SYSTEM SETTINGS
o
Language: Select your language
o
Voice of Alarm: when switched on, an audio alarm will go off as soon as a high temperature
is detected
o
Calibration: if needed, the displayed temperature can be adjusted via the + or
– buttons.
Double check with another device or thermometer to calibrate the unit. (differences can
appear under different types of working conditions)
o
Alarm temperature: set the desired alarm temperature. Controlled people with this
temperature or higher will trigger the alarm.
o
Version: firmware version
•
CLEAR CACHE: used to delete all the recorded images
•
DEFAULT SETTING: used to reset the unit and to go back to all the original factory settings.
MAINTENANCE
During inspection the following points should be checked:
•
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
•
Housings, fixations and installations spots should be totally free from any deformation.
•
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
•
The cleaning of optical lenses must be carried out periodically to optimize performance and reliability.