ENGLISH
9
3.5
Step 5: Commissioning
Before use, make sure that you have followed all the steps
correctly and all the parts are fitted. Place a suitable container
under the cartridge to catch any leakages.
A
Turn on the cold water supply and check the system carefully for
any leaks.
B
Open the valve on your tap and rinse through until the filtered
water runs clear and without any bubbles (at least 1 litre).
4
Replacing the filter cartridge
The filter cartridge must be replaced six months after first use,
regardless how old the filter cartridge is.
NO
TE
The filter cartridge can be pivoted by 90° in the wall mount
for easy removal. When the locking handle is open, the
water supply to the cartridge is interrupted and by-passing
with direct water flow from the water inlet to the outlet is
possible.
Replacing the A 1000 (see fig. 4):
A
Open the locking handle (3).
B
Place a suitable container under the flush hose to catch the rinse
water. Activate the flush valve (6) and release the pressure in the
system.
C
Remove the exhausted filter cartridge (5) from the filter head (2).
D
Use the new filter cartridge (see chapter 3.3 Step 3).
E
Close the locking handle (3).
5
Resetting the electronic cartridge exchange
indicator
A
Press the DISPLAY button briefly to activate the display.
B
Press and hold the START/RESET button for 5 seconds until a
long beep sounds.
C
The last 180 programmed days appears in the display.
D
The timer starts automatically.
6
Maintenance
Regularly check the filter system for leaks. Regularly check the
hoses for kinks. Bent hoses must be replaced.
Even though the product life time is 10 years, we recommend to
check it after 5 years after extraordinary wear and tear.
!
Prior to exchanging the filter system, read the Technical
Data (chapter 7) and the Operating and Safety Information
(chapter 9).
Regularly clean the outside of the filter system with a soft, damp
cloth.
!
Do not use any abrasive chemicals, cleaning solutions or
astringent cleaning agents.