Document: SLSA-MIP-5-4-0-US
Date of Issue: 05/2016
Revision: -
13-5
Unscrew securing nut (4) from the vent (3).
Remove the vent (3) from the instrument panel (5).
Fig. 13-4
Removal / Installation of the vents
1 - Glareshield
2 - Hose
3 - Vent
4 - Securing nut
5 - Instrument panel
13.3.4
Installation of eyeball vents
see Fig. 13-4.
Insert the vent (3) into the instrument panel (5).
Screw securing nut (4) on the vent (3).
Plug the hose (2) into the vent (3)
Install glareshield (1).
13.4
Check / Adjustment
13.4.1
Adjusting the heating control
Adjust the control by screwing or unscrewing the control cable terminal from the
control flap.
After adjustment of the control, mark the mutual position of the control cable terminal
and the flap controller with red color.