Maintenance

Servicing the Valve

This valve should at least be serviced 

with a frequency as set out in the TMV 

manual guidelines to comply with the 

scheme. It may need more frequent 

servicing if sited in a hard water area to 

ensure optimum performance.

Please see the TMV manual supplied 

with this valve for more details.

To service the valve, follow  

the steps below: 

1.  Turn both isolating lugs to shut-off 

the water supplies. (Fig 3). Remove 

the valve from the wall. 

2.  Remove the filters from the isolating 

lugs and rinse of any debris. 

3.  Remove the knob insert. Undo and 

remove the retaining screw. Remove 

the control knob, ring and sleeve to 

expose the head assembly. 

4.  Remove the head assembly from the 

body using a 29mm A/F spanner. 

Remove the bottom cap and 

piston assembly together with the 

thermostat and return spring. 

 

Note: The piston can be  

dis-assembled further but this is  

not necessary for cleaning/servicing. 

5.  Remove O-rings and check for 

damage, replace parts if necessary. 

Soak all metal components in a 

suitable solution until fully de-scaled. 

Grease O-rings using a WRAS 

Approved grease.

Re-Assembly

1.  Replace piston ensuring ease of 

movement when in place. This should 

move with light finger pressure. 

2.  Replace spring and bottom cap. 

Screw in gently, DO NOT use 

excessive force. 

3.  Unscrew the bottom cap by 1 1/4 

turns to give correct gap. 

4.  Re-assemble the head assembly 

ensuring the adjusting screw is 

screwed back fully. 

5.  Fit the thermostat into the head 

assembly. Fit the head assembly into 

the valve body. 

6.  Re-fit the sleeve and control knob, 

secure with the retaining screw. 

7.  Fit the valve back onto the wall, 

ensuring the filters are in place. 

8.  Complete the commissioning and 

temperature adjustment steps to  

re-calibrate the valve.,

Summary of Contents for TS6000ECP

Page 1: ...nstructions and User Guide Thermostatic Mixing Valve Models Covered TS6000ECP Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave them...

Page 2: ...to clog up the mechanical areas of the valve This product must not be modified in any way as this will invalidate the guarantee Full access must be made available for future maintenance servicing pur...

Page 3: ...to the wall 5 Connect the valve to the pipework using filters to prevent debris entering the valve not supplied We recommend using a high tightening torque 45 50Nm on all 22mm compression fittings to...

Page 4: ...Ring 1 10 O Ring 1 11 O Ring 1 12 O Ring 1 13 O Ring 1 14 O Ring 1 15 O Ring 1 16 Grub Screw 1 17 Bottom Cap 1 18 Adjusting Screw 1 19 Screw 2 20 Head 1 21 Spindle Nut 1 22 Adjustment Housing 1 23 Ret...

Page 5: ...ot rinsed off straight after use Household bleaches and cleaners contain harsh chemicals and may damage the surface finish Avoid using abrasive cloths scouring pads scrub sponges steel wool or anythin...

Page 6: ...cooler temperature anti clockwise for a hotter temperature 4 Wait for a few minutes after adjusting for the temperature to stabilise Use a thermometer to measure the outlet temperature Repeat steps 2...

Page 7: ...Remove the bottom cap and piston assembly together with the thermostat and return spring Note The piston can be dis assembled further but this is not necessary for cleaning servicing 5 Remove O rings...

Page 8: ...ww bristan com register For any other queries please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice For full guarantee terms...

Reviews: