Installation – Shower Valve
Before Installation
Flush through the pipework to ensure
removal of debris. Turn off the mains
water supply and close any isolating
valves.
1. Inlet positions
The shower valve has three inlet positions
– top, bottom and rear. Rotate the inlet
elbows as required.
With the elbows screwed fully against the
valve body it can be unscrewed a
maximum of 1.5 turns to allow for lateral
tolerance.
Sufficient 15mm diameter supply pipes
should protrude through the finished wall
surface to fit fully into the shower valve
elbows.
2. Fit shower valve
Position the shower valve into the wall
cavity at the required position and mark the
fixing holes.
Warning: Please check for any
hidden pipes and cables before drilling
holes into the wall.
Drill suitable holes and insert the wall
plugs. Position the shower valve back into
the wall cavity and secure in position
using the screws provided.
152mm
Hot
Cold
60mm
fixing holes
Important: Water supplies to the mixer
must be with hot on the left and cold on
the right when viewed from the front.
Hot supply
Cold supply
15