General Information

This product has been tested to the Water Regulations Advisory Scheme (WRAS) and 
satisfies the requirements of the Water Supply (Water Fittings) Regulations 1999 and
current bylaws. For full Installation Requirements & Notes (IRN) please visit
 www.wras.co.uk/directory. 

Designed to comply with BS EN 200 for combination taps to be used within systems 

designed to BS 8558. 

BS 8558 recommends hot water should should be stored and distributed at a 

temperature of not less than 60°C which will minimise the build up of limescale in hard 

water areas.

If the fitting is installed at low pressure (tank fed), then the minimum distance from the 

highest installed position of the outlet to the underside of the cold tank should be at 

least 2 metres to ensure adequate performance. 

This tap should be installed in compliance with the Water Regulations. Where the 

supplies are unbalanced, i.e. Hot water from cylinder tank / cold from the mains, 

approved check valves must be fitted in the supply pipes. 

For further details contact your Local Water Authority.

Specifications

Operating pressure range (bar) 

  

Min  

 

Max

     0.2 

 5.0

Maximum static pressure – 10.0 bar

Inlet Connections: M10 1/2" BSP Flexible Tails with Isolation Valves 

 

System Requirements:

Gravity fed hot & cold (Equal pressures)

Gravity fed hot & cold (Differential pressure, maximum ratio 5:1)

Unvented systems

Instantaneous water heater (Combination boiler)

 

        

Need help? 

Give us a call on 0844 701 6273 and speak to one of our trained advisers.

Summary of Contents for K SNKSL EF C

Page 1: ...s booklet for future reference Installer when you have read these instructions please ensure you leave them with the user Installation Instructions Colonial Single Lever Easyfit Sink Mixer Model cover...

Page 2: ...g instructions have been created to give you all of the information you need and if you need any further help please do not hesitate to contact us Important Safety Information 3 General Information 4...

Page 3: ...lls check that there are no hidden electrical wires cables or water supply pipes This can be checked with the aid of an electronic detector If power tools are used do not forget to Wear eye protection...

Page 4: ...from the highest installed position of the outlet to the underside of the cold tank should be at least 2 metres to ensure adequate performance This tap should be installed in compliance with the Water...

Page 5: ...5 Dimensions Dimensions are nominal and in millimetres Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers 280 298 225 G1 2...

Page 6: ...ound Twists Important Failure to follow these guidelines may result in poor performance and damage to the flexible connecting pipes Important Full access must be made available on installation for fut...

Page 7: ...e 6mm hexagonal key clockwise Once threading has started you can let go of the backnut Before fully tightening the cold connector place the hot connector into the push fit connector ensure it fits ful...

Page 8: ...ipes 4 Cover cap If required place the cover cap over the push fit connector until the tap body is ready to be fitted 5 Fit the tap body Remove the cover cap and place the plinth over the push fit con...

Page 9: ...9 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers Operation Off On Hot Cold Temperature Control Flow Control...

Page 10: ...ying out any maintenance turn off the mains water supply and close any isolating valves Unscrew the handle lever and loosen the grub screw Remove the handle Remove the shroud cartridge retaining and t...

Page 11: ...o not use other water outlets when using the taps Airlock or partial blockage in the supply pipework Flush through pipework to ensure removal of debris and any airlocks Water dripping from taps This i...

Page 12: ...lease use this space to add any notes you or your installer may have regarding the plumbing system installation of this product Need help Give us a call on 0844 701 6273 and speak to one of our traine...

Page 13: ...lease use this space to add any notes you or your installer may have regarding the plumbing system installation of this product Need help Give us a call on 0844 701 6273 and speak to one of our traine...

Page 14: ...lely to the original purchaser with proof of purchase The installation must allow ready access to all products for the purpose of inspection maintenance or replacement Repair under this guarantee does...

Page 15: ...n to fix any problems with a product Expert advice Find easy to follow how to video guides and technical FAQs online at www bristan com Our guides take you step by step through many product instal lat...

Page 16: ...re B78 1SG Web www bristan com Email enquire bristan com A Masco Company Part Number K SNKSL EF C Issue D1 Useful contact details Customer Service 0844 7016273 Customer Service Email Customercare bris...

Reviews: