WATER PRESSURE
This mixer is suitable for use at all supply pressures. However for
optimum use both the hot and cold supplies should be reasonably
balanced. If the fitting is installed at low pressure (tank fed), then the
minimum height from the highest installed position of the
showerhead to the underside of the cold tank should be 1 metre to
ensure adequate shower performance.
This mixer should be installed in compliance with Water
Regulations. Where the supplies are unbalanced, i.e. hot water from
cylinder tank/cold from the mains, approved check valves must be
fitted in the supply pipes. For further details contact your Local
Water Authority.
INSTALLATION
1. Identify all components and check for completeness, particularly
before arranging fitting.
2. Fit the mixer body to the bath using the gasket and backnuts,
connect the hot and cold water supplies.
3. Fit the hose to the mixer and the handset using the small sealing
washers.
4. Fix the wall bracket to the wall ensuring that the handset will
reach it.
5. Fully open both valves, letting them run for a few minutes to flush
the system.
6. Operate the mixer in both bath and shower mode.
To switch from bath to shower mode, pull the diverter up. After use
the mixer automatically reverts to the bath filling mode.
7. See over the page for aftercare instructions.
MAINTENANCE
If the fitting begins to drip:
1. Turn off the water supply.
2. Prise off cap, loosen grub screw with 2.5mm hexagon key and
pull off head.
3. Remove valve.
4. Carefully clean seating, rubber washer and ceramic disc.
5. Replace valve and head and turn on the water supply.
6. Contact our helpline if problem persists.
Please note:
Before Installation, please write the name and product
code of your fitting in the spaces provided overleaf. This will ensure
a speedier service if you should need to phone the help line.