Bristan GLE3105 B Installation Instructions And User Manual Download Page 22

Guarantee 

Thank you for purchasing a Bristan product. This 

product has been designed and tested, in the UK, to 

the highest standards.

Guarantee: 2 Year parts. 

 1 Year labour (subject to registration). 

This guarantee applies to products purchased within 

the United Kingdom or Republic of Ireland, but does 

not apply to products used commercially.

This is provided that:

1. The guarantee registration card is completed and 

returned within ten days complete with a copy of 

proof of purchase. Proof of purchase is required for 

any servicing requirements.

2. The product is installed and operated in 

accordance with our instructions, the I.E.E Wiring 

Regulations, and Building Regulations (Part P), and 

has not been misused or damaged.

This in no way affects your statutory rights as a 

consumer. 

The information on the Guarantee card helps Bristan 

to process any claims and contact you about 

your product and its maintenance if required. The 

registration of your personal details is purely for 

Bristan use and the remaining information helps us 

to make products for the future.

Should a complaint arise, products are guaranteed 

against faulty workmanship and materials for a 

period of 12 months from the date of purchase, 

when in domestic use (second year guarantee is 

parts only). For your guarantee to be valid, your 

shower must be installed by a competent person, in 

accordance with the instruction manual. 

Bristan will repair or replace (at our option), free of 

charge, any faulty components during the guarantee 

period, provided it has been maintained and 

operated in accordance with our instructions, and 

has not been misused or damaged.

Modification or repair of this product by person(s) 

not authorised by Bristan will invalidate this 

guarantee.

This guarantee does not affect your statutory rights.

Service Policy 

Replacement Parts Policy

Important: 

In the event of product or component malfunction,  

DO NOT tamper with or remove the product from 

site. Telephone the Customer Services Department 

and be prepared with the date of purchase, model 

number and a clear description of the complaint.

Our service staff are fully qualified to advise 

on correct installation procedures and will be 

able to diagnose whether the fault will require a 

replacement part or a visit from a Bristan engineer.

If required, a service call will be booked and either 

yourself or an appointed representative (who 

should be a person of 18 years or over) must be 

present during the visit. 

All site visits to product within the guarantee period 

will be carried out free of any parts or labour 

charges provided the conditions of the guarantee 

have been adhered to (the second year guarantee 

is parts only).

All site visits to product out of guarantee will be 

subject to charges for parts and labour. Charges will 

also be levied on cancelled appointments, unless 

advised to Bristan at least 24 hours in advance of 

the agreed date and time.

Should a product be discontinued, spare parts 

stocks will be maintained, but in the event of a part 

becoming unavailable Bristan reserve the right to 

supply a substitute of equal quality.

Please visit: www.bristan.com/search and search for 

your product code in order to find spare parts for 

this product. 

Opening times: Please refer to the Bristan website.

Customer Service: 

Tel: 0330 026 6273
E-mail: [email protected]

22

Need help?

 Give us a call on

 0330 026 6273

 and speak to one of our trained advisors.  

Guarantee

Summary of Contents for GLE3105 B

Page 1: ...E395 W GLE395 B GLE3105 W GLE3105 B Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave them with the user Installation Instructions a...

Page 2: ...eaturing a contemporary design with lots of fun features Bristan s electric shower collection has been designed to be enjoyable to fit and to use It has also been designed and tested in the UK to all...

Page 3: ...roughly and retain for future use All products manufactured and supplied by Bristan are safe provided they are installed used correctly and receive regular maintenance in accordance with these instruc...

Page 4: ...t has been designed to be modified by the installer Fit only shower heads recommended by the manufacturer You must not fit a water saving handset whereby the flow of water can be restricted or turned...

Page 5: ...high and the water inside the water heater gets too hot The Temperature Control Device will switch off the power to the heating elements Once the unit cools down to a safe temperature the elements wil...

Page 6: ...side Top Bottom Rear bottom Right hand side Bottom Rear bottom Operating Pressures Minimum working pressure 0 07 MPa 0 7 bar Maximum working pressure 1 0 MPa 10 bar Static pressure range 0 1 0 MPa 0 1...

Page 7: ...must not be connected to a ring main spur power socket or lighting circuit If you don t have a spare fuse way or the rating at the main fuse box is below 80A you should seek advice from an electrician...

Page 8: ...ng factors On installation of the appliance the impedance measurement of the Neutral and Earth back to the supply source is to be less than 1 0 Ohms This is in line with the general installation requi...

Page 9: ...e spill over level of the bath or shower tray or other fixed appliance If a showerhead can sit within a bath basin or shower tray you must fit a double check valve in the supply pipe work to prevent b...

Page 10: ...ble pencil through the paper Remove the template from the wall and drill the wall to suit the wall fixings to be used Tips A piece of insulation or masking tape positioned where holes are to be drille...

Page 11: ...inlet entry Rear left inlet entry using a 15mm compression elbow not supplied where NO rear access is available Rear left inlet entry requiring rear access Rear right inlet entry requiring rear access...

Page 12: ...pipe work can enter the shower unit from 6 different positions Bottom left Bottom right Top left Rear left Rear right or Rear left using an elbow as shown on page 11 To top or bottom left positions Th...

Page 13: ...for water leaks at the shower inlet Once inspected turn off the water supply Pressure Relief Device PRD A pressure relief device is designed into this shower The pressure relief device provides prote...

Page 14: ...This appliance and all connecting metal pipe work must be earthed Ensure that an earth continuity conductor is securely and permanently connected to all exposed metal parts of other services and appl...

Page 15: ...e directed to the terminal connection block within the unit Note When feeding cable through bottom entry points remove highlighted grey tab on pipe blanking cover if using 6mm cable For 10mm cable rem...

Page 16: ...cured by routing through conduit or in trunking or by being embedded in the wall in accordance with current I E E Regulations Warning Do not switch on power to the shower unit until the cover and the...

Page 17: ...ng shower installation Drill the wall at the marked fixing position to suit the wall fixings to be used loosely fix the rail with the large hole on the side shown and wall bracket Check that the rail...

Page 18: ...ure control knob 4 from the fully clockwise position to the fully anti clockwise position Repeat this procedure several times until a continuous flow of water with no air bubbles is obtained from the...

Page 19: ...nd wait for the new temperature to settle before changing again To Stop the Shower Press the STOP START button 2 Phased Shut Down When the shower is turned off water will continue to flow for a short...

Page 20: ...on that routine service cleaning is advisable to maintain showering performance Follow the instructions to Clean the Showerhead Clean the Inlet Filter and Clean the Outlet Hose Mesh Filter Cleaning th...

Page 21: ...increases before using again Increase water flow rate by turning temperature control to cooler setting Error code E1 appears in temperature indicator display Outlet water temperature thermistor fault...

Page 22: ...used or damaged Modification or repair of this product by person s not authorised by Bristan will invalidate this guarantee This guarantee does not affect your statutory rights Service Policy Replacem...

Page 23: ...ws x2 1 09 131 308 Pressure Relief Diaphragm Pressure Relief Diaphragm x1 1 10 131 400 S Water Inlet Ass Inlet Elbow x1 Swivel Inlet Pipe x1 Filter x1 inc O rings x3 1 11 131 406 S Inlet Elbow Ass Inl...

Page 24: ...7 15 20 4 17 8 9 19 10 1 5 6 11 12 13 14 18 24 Need help Give us a call on 0330 026 6273 and speak to one of our trained advisors Spare Parts...

Page 25: ...l Ass Riser Rail x1 Riser Rail End Caps x2 1 04 62000022 2 Slider Handset Holder Slider Handset Holder x1 1 05 81M500601 103 101 Soap Dish Soap Dish x1 1 06 61000019 Handset White Handset x1 1 06 81S1...

Page 26: ...this space to add any notes you or your installer may have regarding the plumbing system installation of this product 26 Need help Give us a call on 0330 026 6273 and speak to one of our trained advi...

Page 27: ...this space to add any notes you or your installer may have regarding the plumbing system installation of this product 27 Need help Give us a call on 0330 026 6273 and speak to one of our trained advi...

Page 28: ...our products effective from the date of purchase to give you peace of mind To start your free guarantee simply scan the QR code and register your product Alternatively visit www bristan com register F...

Reviews: