Switch OFF the electricity supply at the consumer unit.
The power cable entry point is shown on the diagram.
Electrical connection to be made at the terminal block as follows:
Earth cable to the terminal marked with the Earth symbol
Neutral cable to the terminal marked
N
Live cable to the terminal marked
L
Important: Terminals must be fully tightened onto the cables
ensuring that no cable insulation is trapped under the screws.
It must be metal to metal. Loose connections can result in the
cables overheating, ensure all terminal screws are fully tightened.
The supply cable earth conductor must be sleeved. The supply
cable must be secured by routing through conduit or in trunking
or by being embedded in the wall in accordance with current I.E.E
Regulations.
Warning: Do not switch on power to the shower unit until the
cover and the cable to connection (10) have been fully fitted.
•
Plug in the cable from the cover to the connection (10) inside the
unit.
•
Rotate the temperature control knob (6) fully anti-clockwise
(full cold).
•
Rotate the splined temperature control spindle (6a) fully
anti-clockwise.
•
Locate cover in position ensuring wiring is not trapped.
Note:
slight adjustment of the knob may be required to locate
cover correctly.
•
Secure using the 4 cover fixing screws supplied and fit screw
covers.
L
L
N
L
N
L
N
10
6
6a
10