Bristan AR2 SHXVOFF C (D2) Installation Instructions & User Manual Download Page 2

7

4

4

2

1

Remove 

temperature 

handle

Replace 

temperature 

handle

Turn flow handle to ‘on’ 

position, letting temperature 

stablise.

Turn cartridge spindle clockwise 

to decrease the temperature.

Turn cartridge spindle 

anti-clockwise to increase the 

temperature.

3

5

2

Remove 

temperature and 

flow handles

Using the wall 

mount, isolate  

both shower 

inlets before 

carrying 

out  any  

maintenance.

Unscrew the 

cartridge using 

a socket or box 

spanner

Remove the 

 valve using a socket 

 or box spanner

Troubleshooting

To reduce the build 

up of limescale and 

to ensure this shower 

works to its maximum 

performance we 

recommend 

this shower is 

serviced every 

6-12 months 

depending on 

the hardness 

of your water.

To replace any spare parts for your shower why not scan the QR Code 

and search for your product.

Spare Parts

Servicing Intervals

Temperature Setting

Maintenance - Cartridge Cleaning

3

1

6

Turn the water 

supply to the 

shower back on.

Symptom

Cause

Remedy

No flow or 

low flow rate

Partially closed isolation valve.

Open isolation valve.

Instantaneous water heater cycles on and off 

as flow rate or pressure is too low.

Increase water flow rate or 

pressure through system.

Head of water is below the 

minimum distance required.

2 meters minimum required. 

Hot or cold water being drawn off elsewhere 

causing pressure changes or instantaneous 

boiler temperature changes.

Do not use other water outlets when using the taps.

Airlock or partial blockage in the supply 

pipework.

Flush through pipework to ensure removal of debris and 

any airlocks.

Water 

dripping 

from shower

This is normal for a short time after using the 

shower.

This is caused by residual water tension, the build up of 

water in the shower.

If water continues to drip, 

possibly due to the cartridge

Remove cartridge and clean, refer to 'Maintenance' section 

before starting any maintenance.

Shower does 

not turn on

Closed isolation valve.

Open isolation valve.

Mains water supply turned off.

Turn on mains water supply.

REMEMBER

 

To service 

your 

product!

At Bristan, we want to make things as easy as possible for our customers. That’s 

why we offer solid guarantees on 

all our products, effective from the date of purchase, to give you peace of mind. 

To start your free guarantee simply scan the QR code and register your product.  

Alternatively visit www.bristan.com/register. 

For any other queries, please call our Customer Service on 0330 026 6273 where 

our expert team of advisors will be able to offer you any help and advice. 

For full guarantee terms and conditions visit www.bristan.com/guarantees.

34

5

Reverse steps 5-2 to 

reinstall the valve, 

cartridge and handles.

Remove O-rings

and soak all

components in

de-scaler and wash off in clean

water. Examine all seals and

replace if needed. Use WRAS

approved silicon based grease

on all seals.

Operation

On

Off

Hot

Cold

Reviews: