7
4
4
2
1
Remove
temperature
handle
Replace
temperature
handle
Turn flow handle to ‘on’
position, letting temperature
stablise.
Turn cartridge spindle clockwise
to decrease the temperature.
Turn cartridge spindle
anti-clockwise to increase the
temperature.
3
5
2
Remove
temperature and
flow handles
Using the wall
mount, isolate
both shower
inlets before
carrying
out any
maintenance.
Unscrew the
cartridge using
a socket or box
spanner
Remove the
valve using a socket
or box spanner
Troubleshooting
To reduce the build
up of limescale and
to ensure this shower
works to its maximum
performance we
recommend
this shower is
serviced every
6-12 months
depending on
the hardness
of your water.
To replace any spare parts for your shower why not scan the QR Code
and search for your product.
Spare Parts
Servicing Intervals
Temperature Setting
Maintenance - Cartridge Cleaning
3
1
6
Turn the water
supply to the
shower back on.
Symptom
Cause
Remedy
No flow or
low flow rate
Partially closed isolation valve.
Open isolation valve.
Instantaneous water heater cycles on and off
as flow rate or pressure is too low.
Increase water flow rate or
pressure through system.
Head of water is below the
minimum distance required.
2 meters minimum required.
Hot or cold water being drawn off elsewhere
causing pressure changes or instantaneous
boiler temperature changes.
Do not use other water outlets when using the taps.
Airlock or partial blockage in the supply
pipework.
Flush through pipework to ensure removal of debris and
any airlocks.
Water
dripping
from shower
This is normal for a short time after using the
shower.
This is caused by residual water tension, the build up of
water in the shower.
If water continues to drip,
possibly due to the cartridge
Remove cartridge and clean, refer to 'Maintenance' section
before starting any maintenance.
Shower does
not turn on
Closed isolation valve.
Open isolation valve.
Mains water supply turned off.
Turn on mains water supply.
REMEMBER
To service
your
product!
At Bristan, we want to make things as easy as possible for our customers. That’s
why we offer solid guarantees on
all our products, effective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where
our expert team of advisors will be able to offer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/guarantees.
34
5
Reverse steps 5-2 to
reinstall the valve,
cartridge and handles.
Remove O-rings
and soak all
components in
de-scaler and wash off in clean
water. Examine all seals and
replace if needed. Use WRAS
approved silicon based grease
on all seals.
Operation
On
Off
Hot
Cold