BriskHeat
®
Corporation. All rights reserved
4
XtremeFLEX
®
HSTAT-R Emergency De-Icer
SPECIFICATIONS
Operating conditions:
Maximum Operating Temperature: 160°F (71°C)
Adjustable Thermostat Control 50-160°F 120 VAC
Power Density: 6.0 watts/in
2
Moisture and Chemical Resistant
Suitable for Electrically Conductive
Surfaces
Includes 6-foot power cord with standard 2
prong plug
HOW TO INSTALL A DE-ICER
Read and understand this entire manual before operating this electric heating tape.
NOTE: DO NOT INSTALL ON PLASTIC SURFACES. USE ON METAL SURFACES ONLY.
STEP 1
Remove de-icer from packaging. Visually inspect de-icer. Do not use if torn or
damaged.
STEP 2
The flexible emergency de-icer can be installed on both a flat and/or curved
surface. For a flat surface, lay the de-icer tape onto the surface to be heated.
For a curved surface, wrap the heating tape onto the surface to be heated.
Attach the de-icer tape to the surface by using an aluminium or fiberglass
adhesive tape, rated to a minimum temperature of 170°F.
Ensure the de-icer tape is not kinked, twisted, or any portion of the
heating tape hanging free from the surface (A).
Do not overlap de-icer tape on itself (B).
Thermostat sensor must be in full contact with object to be heated.
Sensor is located underneath temperature controller box (C).
STEP 3
Plug power cord into appropriate electrical power outlet.