background image

 

 

 17 

AF36 US Issue 03 

 
 
 

 

 

7 EGGS

 

 

 

SETTING THE TURNING OPTIONS 

 

 

 

1.

 

Pres s   the  -  a nd  +  buttons              
s i multaneously to unlock the 
Ma i n Menu. 

 

2.

 

Pres s  + to scroll to the TURN 
0/1 opti on. 

 

3.

 

Pres s  OK to select the turning 
mode s creen a nd us e the + 
a nd 

 buttons to set to ON or 

OFF a s  required. 

 

4.

 

Pres s   OK  to  return  to  the 
Ma i n  Menu.  The  TURN  INT 
opti on will now be displayed. 
Pres s   OK  to  s elect  the  turn 
i nterval s creen a nd use the + 
a nd 

 buttons to set the delay 

between turns i n minutes as 
requi red. 

 

5.

 

Pres s  OK to return to the 
Ma i n Menu and then scroll 
down to SAVE. Press OK to 
s a ve the changes. 

 
 
 
 

 

 
 
 

 

 

 

STORING, SETTING AND TURNING EGGS

 

Ens ure that you store eggs in cool, damp conditions. Most species may be safely s tored for up to 14 days before serious  reductions in 
ha tch ra tes are l ikely. Daily turning of stored eggs also helps maintain hatchability. 

Di s card cracked, mis-shaped and heavily soiled eggs (if possible). Only wash soiled eggs using a brand ed egg wash solution such as Brinsea 
Incubation Disin

fectant Concentrate following the manufacturer’s instructions. It is essential to wash eggs in solution which is significantl

wa rmer than the egg. Bear in mind that all s olutions will remove the outer cuticle from the egg as well as the dirt a nd may l eave the egg 
a t grea ter ri sk from bacterial contamination in the future. 

The Ova ti on 28 Adva nce is designed to accommodate eggs of different sizes from pheasant to duck eggs or larger/ smaller eggs using the 
a l ternative egg carri er. 

Before setting eggs ensure that the i ncubator has been running for s everal hours a nd has stabilised at the correct temperature. 

Set the eggs in the egg carriers provided. The eggs need to be set lying flat or with their pointed ends facing down. Switch the turning 
s ys tem on. A revol

ving line s ymbol “/” s hould be s hown i n the corner of the display.

 

Check the water level every 2 days  or s o and temperature daily. Ca ndle the eggs after 1/3rd of the incubation period has elapsed to reject 
cl ea r, infertile eggs. Remember to s top the turning 2 days before the eggs a re due to hatch. 

 
 
 

 

Pointed ends of eggs facing down

 

 

Eggs lying flat

 

 

Summary of Contents for Ovation 28 Advance

Page 1: ......

Page 2: ...tructions safe forfuture reference This document includes recommended procedures for successful hatching but incubation involves the control and manipulation of a large number of factors and in certaincircumstancesdifferentproceduresmaybe necessary For more detailedinformationonall aspectsof eggincubationincludinghelpfuladvice ongettingbestresultspleasevisit ourwebsite atwww brinsea com Your incub...

Page 3: ...s Assembly Location Installation 2 Product Introduction Functional Features 3 Settings Control Menu 4 Display 5 Temperature 6 Humidity and Ventilation 7 Eggs 8 Periodic IncubationCooling 9 Hatching Cleaning up 10 Specifications CONTENTS 4 5 6 9 10 11 12 14 15 17 18 19 20 ...

Page 4: ...m the incubator and parts Retain the carton and packing materials to enable the unit to be repacked 1 Remove the packaging and lift off the top ofthe incubator 2 Remove the card packing inserts and elastic bands from inside the incubator 3 Check that the electrical supply matches the machine s requirements marked on the technical label inside the clear top 1 2 ...

Page 5: ...o you Ensure you have the correct quantities of each part If there are any parts damaged or missing please contact your retailer or Brinsea Products at the address at the end of the document Damagedappliances must not be used 1 Top 2 Egg Carriers 4 3 Link 4 Water Pan Shutter 1 5 Water Pan Covers 2 6 Base 7 HatchingMat 3 6 5 7 ...

Page 6: ...ASSEMBLY 1 Fit the water pan shutter to the water pan cover 2 Place the water pancovers into their positions in the base See section 6 for advice on humidity 3 Fit the link into its slots ensuring the smooth side is facing inwards 2 1 3 Link slots ...

Page 7: ...7 AF36 US Issue03 1 SETTING UP YOUR INCUBATOR ASSEMBLY 4 Fit the egg carriers into the supports The pegs must fit in the sockets 4 Detail A Detail B Detail A Detail B ...

Page 8: ... US Issue03 5 1 SETTING UP YOUR INCUBATOR ASSEMBLY 5 Place the top onto the base in the correct orientation The egg turning motor must sit over the link Check the topfits flushall the wayaround the base edge ...

Page 9: ...oomtemperature cannot dropon a cold night Ideallythermostaticallycontrol the room at between 68 and 77 F 20 and 25 C Never allow the room temperature to dropbelow 59 F 15 C Make sure that the incubator cannot be exposedto direct sunlight and is used on a flat level surfaced worktop or table not onthe floor Please ensure the incubator is used on a water resistant surface Connect the mains cable to ...

Page 10: ...10 AF36 US Issue03 2 PRODUCT INTRODUCTION FUNCTIONAL FEATURES 1 Digital Display 2 Control Buttons 3 Adjustable air vent 4 Egg Carriers 4 5 Water Pan Shutter 1 2 3 4 5 ...

Page 11: ...ATURE ALARM Range 1 0 5 0 C 1 8 9 0 F belowset incubationtemperature Default 3 0 C 5 4 F See section4 CELSIUS FAHRENHEIT DISPLAY Switches all temperature figures between Cand F Default C See section5 SAVE All changes are saved Returnto normal operationscreen CANCEL All changes are ignored Return to normal operationscreen TURNING MODE Switches the turningsystemon oroff Default ON TURNING INTERVAL S...

Page 12: ...ona line symbol rotates at the corner of the display Changing Settings The Control Menu allows the various settings to be modified and saved All settings are retained in the event of a power cut To access the Control Menu pressthe and buttons simultaneouslyto unlock the display For full details ofmenusettings please refer to the contents onpage 3 andview the relevant sections Power Loss Display FI...

Page 13: ...to candle eggs a number of timesafter this event to checkfor losses Low Room Temperature Alarm FIG 4 If the calculated room temperature remains too low for optimum results for more than 1 hour a warning is displayed RM and an alarm will sound Press OK to silence the alarm for 30 minutes If the low temperature problem rectifies itself the RM remains on the displayto show thishas happened Press OKto...

Page 14: ...ture in the menu to suit the types of eggs youare incubating As the incubator warms up andapproaches its control setting the heater on asterisk will change fromcontinuouslyon to flashing Allowthe incubator to stabilise for at least an hour before adjusting the temperature Recommended temperatures Typical incubation period Hens 99 3 99 6 F 37 4 37 6 C 21 days Pheasant 99 6 100 0 F 37 6 37 8 C 23 27...

Page 15: ...ncubator will alsohave aneffect There are two methods available to bird breeders to achieve correct humiditylevels 1 Monitor humidity levels and adjust to match published guidelines for different species 2 Monitor egg weight loss which varies as a direct result of humidity and correct against published weight loss figures for the species This is the most reliable method and is recommended particul...

Page 16: ... hatching the high humidity levels will fall dramaticallywhenthe lidis opened and will take some time to build up Resist the temptation to lift the lid frequently leave for at least 6 hours between inspections In practice the minimum and maximum levels of humidity achievable in an incubator depend upon several factors including the ambient conditions in the incubationroom You mayneedto allow24 hou...

Page 17: ...nsuch asBrinsea IncubationDisinfectant Concentrate following the manufacturer s instructions It isessentialto wash eggs insolutionwhichis significantly warmer thanthe egg Bear in mindthat all solutions will remove the outer cuticle from the egg as well as the dirt and mayl eave the egg at greater riskfrom bacterial contaminationin the future The Ovation28 Advance is designedto accommodate eggs ofd...

Page 18: ...et Each cooling periodstarts at approximatelythe same time each day 24 hours betweenstart times The first coolingperiod will start 24 hours after the incubator was last switchedon If there is a power interruptionthe 24 hour delaystarts again During the coolingperiod the heater asteriskgoes off and anarrow is displayed Whenthe cooling periodends the asterisk is shownandthe incubator warms to incuba...

Page 19: ...SHWASHERTO CLEAN ANY PARTS OF THE INCUBATOR Following eachhatch inthe Ovation 28 Advance remove andwashthe egg carriers linkand base in Brinsea IncubationDisinfectant Solution and then rinse thoroughly Use a vacuumcleaner andsoft brushto remove dust from the fanguard Wipe allother internal surfaces with a cloth made damp with the solutionandthen wipe offwitha cloth made damp withcleanwater Ensure ...

Page 20: ...age 30 Watts Electrical Supply 230v 50Hz or 110V 60Hz as ordered 7 heneggs inhen egg carrier 7 duck eggsin hen eggcarrier 19 pheasant eggsin optional large egg carrier 22 quail eggsin optional large egg carrier The large eggcarriers are available from brinsea comor your local stockist productcode AG011 Brinsea Products Inc 704 N DixieAve Titusville FL 32796 2017 USA Phone 321 267 7009 Toll Free 1 ...