7.6
To assemble the hatching trays place a white plastic peg in each of the four corner sockets on an
Ova-Easy universal tray as shown below. The wide end of the peg should make a push fit into the
socket. Another universal tray may then be placed upside-down over the narrow end of the pegs to
form a secure lid over the hatching eggs. When the lid is removed the pegs will stay fixed in the
bottom tray.
7.7
Do not place paper towels or other objects in the bottom of the trays as this will impede flow of air. The
eggs are placed directly in the bottom of the tray.
7.8
During hatching the high humidity levels will fall dramatically when the door is opened and will take
some time to build up. Resist the temptation to open the door frequently
– leave for at least 6 hours
between inspections.
7.9
When most eggs have hatched (12 to 48 hours) move the hatchlings to a brooder.
8 Cleaning Up
IMPORTANT:
DISCONNECT THE HATCHER FROM THE MAINS POWER SUPPLY DURING CLEANING.
ENSURE THAT ALL ELECTRICAL PARTS ARE KEPT DRY.
NEVER WASH THE TRAYS, INSULATED PANELS, FASCIA OR EVAPORATION TRAY PARTS
WITH LIQUIDS OVER 50°C (120°F). DO NOT USE A DISHWASHER TO CLEAN THESE PARTS.
NEVER ALLOW CLEANING WATER TO COME INTO CONTACT WITH THE TEMPERATURE AND
HUMIDITY SENSOR. THIS IS SUSPENDED INSIDE THE AIR OUTLET VENTS AT THE FRONT
OF THE HATCHER. CONTAMINATION MAY DAMAGE THE SENSOR.
8.1
Following each hatch remove and wash the egg trays in Incubation Disinfectant Solution. Wipe all
other internal surfaces with a soft cloth soaked in the solution. Ensure that the instructions supplied
with the fluid are followed. Dust and fluff may be removed from the fan guard area with a soft brush.
8.2
The exterior of the Hatcher may be cleaned with a damp cloth. Avoid allowing any moisture to get
inside the top electrical housing or electrical connector at rear.
8.3
Always clean the Hatcher before storage and ensure that the unit is totally dry inside and out.