5 Operating the pump controller
154
bplogic intelligent pump controller
18/02/2021
Ap
p
lica
ti
o
n
-si
n
g
le
-vi
e
w
_
C
SM
-0
1
.p
n
g
Fig. 86: Application single view for a logic module
1
Displays the number of actions for which parameters were set for the logic
module. The number of actions does not have to match the number of the
last action for which parameters were set, as the “Go to action” command
can be used to bypass functions.
2
Displays the number of the selected action. The number of available actions
do not have to be sequential, as the “Go to” command can be used to by-
pass functions.
2.
Select an action for the logic module in the application single view’s left display
area. To do so, either use
and
to select an action or enter an action
number in the input field (Fig. 86/2).
The right display area displays the settings for the selected action.
3.
Use to scroll one screen forward in the left display area.
The left display area displays the designations for the source and target pa-
rameters defined for the action (Fig. 87/1).
Follow-up time